Edwards Installation Sheet, Genesis Strobe

File Preview
File Preview
Click below to download for free

File Data

Name edwards-installation-sheet-genesis-strobe-8942637051.pdf
Type PDF
Size 770.91 KB
Downloads

Text Preview

information 1 Models to 110 multi cd with FIRE marking plate plate with FIRE marking plate Strobe number MG1RF VM plate with FIRE marking Genesis Strobe is a visible fire alarm notification appliance for indoor walls See Table 1 for a list of model strobe includes a field configurable switch for selecting the candela output and a field configurable jumper for the signal output The candela output setting is locked in and remains visible after final installation strobe features an enhanced synchronization circuit to with the latest requirements of UL 1971 Signaling for the Hearing Impaired and the latest Canadian CAN ULC S526 02 Synchronized operation requires separately installed synchronization control module See 2 for a list of compatible synchronization modules this device in accordance with applicable requirements the latest editions of the NFPA codes and standards and Electrical Code Part 1 Section 32 CAN ULC S524 Standard for the Installation of Fire Alarm Systems and in with the local authorities having jurisdiction 1 Models to 110 multi cd number to 110 multi cd with FIRE marking to 110 multi cd 2 Compatible synchronization modules Output Signal Master Mount number SIGA MCC1S LG Signal Master Mount voltage 24 Vdc or 24 Vfwr nominal operating current See Table 3 output Selectable at 15 30 75 and 110 cd Meets UL 1971 requirements Maximum resistance between any two devices is 20 to specifications for the synchronization control this strobe and the control panel to determine wire resistance size 12 to 18 AWG 2.50 to 0.75 sq mm electrical boxes American 2 1 2 in 64 mm deep 1 gang box 4 in square box 1 1 2 in 38 mm 2 gang or 4 in with G1T or G1RT trim accessory environment 32 to 120 0 to 49 0 to 93 RH noncondensing at 90 32 Sheet Strobe P N 3100559 REV 3.0 2 listings Meets year 2004 UL requirements for UL1638 and UL1971 see Figure 1 and requirements for standards CAN ULC S526 02 CAN ULC S524 01 ratings Regulated 24 DC Regulated 24 FWR ratings 20 to 31 Vdc or 20 to 31 Vfwr 3 Strobe operating current in RMS A cd Vdc Vfwr Volts direct current regulated and filtered Volts full wave rectified cd cd cd 10 15 20 2 Candela switch change the strobe to private mode cut circle J1 to edge of circuit J3 of rated output 3 Strobe signal setting and vertical outputs reflect the same pattern 1 UL 1971 minimum light output of rating vs angle instructions To reduce the risk of shock disconnect all power allow 10 minutes for stored energy to dissipate before Electrical supervision requires the wire run to be at each terminal Do not loop the signaling circuit field around the terminals install the strobe Remove the cover by depressing both tabs on the top of unit with a small screwdriver and twisting slightly Slide the candela switch to the desired candela output 15 75 or 110 cd by aligning it with the indicator located the switch See Figure 2 Set the strobe signal if required See Figure 3 Connect the strobe terminals to the signal circuit field You must observe polarity for the unit to function See Figure 4 Mount the unit onto a compatible electrical box making not to over tighten the mounting screws Replace the cover by aligning at the bottom then in at the top Test the unit for proper operation If the strobe is set to temporal private mode this is no longer UL 1971 listed and FM Approved but is UL listed compatible fire control panel next device or of line device Polarity shown in alarm condition 4 Wiring diagram unit is not serviceable or repairable Should the unit fail to contact the supplier for replacement a visual inspection and an operational test twice a or as directed by the local authority having jurisdiction 3100559 REV 3.0 2 Sheet Strobe

Related Files