Edwards MC Software & Hardware Accessories

File Preview
File Preview
Click below to download for free

File Data

Name edwards-mc-software-hardware-accessories-6815937420.pdf
Type PDF
Size 941.46 KB
Downloads

Text Preview

MESSAGE CENTERS ANNUNCIATORS Center Connectivity String Activation Center Protocol protocol document allows your Edwards Center to communicate directly with any that has a serial port such as PLCs logic controllers or your desktop PC allows you to post real time information quotas or important company information your own software application String Requirements Communicating device such as a PC or PLC must either a RS232 or RS485 communication Software being utilized must be capable of an ASCII text string through the output Supported Set and display time and date Set run schedules for particular messages Control text with color font and character height Read status from any message center Special functions rotate scroll flash etc Address messages for specific message centers Fieldstone Court Cheshire CT 06410 h 2 0 3 6 9 9 3 3 0 0 F x 2 0 3 6 9 9 3 1 0 8 Copyright 2002 Edwards CENTERS ANNUNCIATORS Center Hardware Networking Accessories MESSAGE CENTERS ACCESSORIES Modular Network Adapter Used an RS485 Network Allows a network drop or MCN485 RJ11 1 to be to an Edwards Message Center RS232 to RS485 Converter Box is supplied with 2 end of line terminators and supply Used when more than one message is needed on the same network End of line terminator In an network an EOL terminator must be used at end to ensure proper operation Converter Box power supply 120VAC input 9 volt output Used to power Converter Box RS485 Network repeater box an additional 32 drops on an RS485 8 ft 4 conductor RS485 network Used in conjunction with a MCNMNARJ11485 required for each message center in an RS485 to ensure proper operation 1 ft 4 conductor RS485 network Used in conjunction with a MCNMNARJ11485 required for each message center in an RS485 to ensure proper operation 1000 ft spool of RS485 cable 100 ft length of RS485 cable 8 ft RS485 cable Used to 2 Edwards Messages Centers when back to back Copyright 2002 Edwards ACCESSORIES 25 pin sub D 6 position RJ11 This is used to convert 25 pin Serial output a PC to an RJ11 connection 9 pin sub D 6 position RJ11 This is used to convert a 9 pin Serial output a PC to an RJ11 connection 9 pin female 25 pin male RS232 Used to connect 25 pin Serial output on a to a 9 pin RS232 cable 6 position coupler for connecting cable together 25 foot 6 conductor RS232 cable to connect Serial output on PC to a Message 50 foot 6 conductor RS232 cable to connect Serial output on PC to a Message 10 foot 25 pin female 9 pin male RS232 cable Used to connect receiving to an RS232 to RS485 Converter Box 10 foot 9 pin female 9 pin male RS232 cable Used to connect Serial of a PC to an RS232 to RS485 Converter Box Fieldstone Court Cheshire CT 06410 h 2 0 3 6 9 9 3 3 0 0 F x 2 0 3 6 9 9 3 1 0 8 CENTERS ANNUNCIATORS Center Connectivity Held Wireless Remote NETWORK WITHOUT A PC Message centers are interconnected using RS485 Message centers are programmed utilizing the hand remote control Most basic way of networking multiple message No MCN485EOLTCB MCN485 RJ11 8 EOL terminator ferrite towards sign incl w cable foot 4 conductor RS485 cable foot 4 conductor RS485 cable MCNMNARJ11485 Modular Network Adapter cable 1000 foot spool Remote Control keypad The internal jumper must be set for RS485 operation Networking Software SINGLE MESSAGE CENTER This connection method is usually a serial port port on your computer or a output on a PLC Limited to one drop Device Wiring distance is limited to 50 feet RS232 ACCESSORIES MCN2329F 25M 9 pin female 25 pin male adapter MCN232 6PRJ11 6 position coupler for RS232 cable MCN485MODCB 10 foot 25 pin female 9 pin male B9 RS232 cable A9 RS232 cable MCN485CB232A9 10 foot 9 pin female 9 pin male No MCN232 RJ11 25 MCN23225FRJ11 ferrite towards sign incl w cable foot 6 conductor RS232 cable foot 6 conductor RS232 cable pin sub D to 6 pos RJ11 adapter pin sud D 6 pos RJ11 adapter The internal jumper must be set for RS232 operation Fieldstone Court Cheshire CT 06410 h 2 0 3 6 9 9 3 3 0 0 F x 2 0 3 6 9 9 3 1 0 8 Copyright 2002 Edwards CENTERS ANNUNCIATORS Center Connectivity Software MULTIPLE MESSAGE CENTERS RS485 ACCESSORIES More than one device may be connected to the MCN485CBAC converter box power supply 120V AC input 9 volt output An RS485 Network is made up of smaller 32 drop MCN485NRB RS485 network repeater box an additional 32 drops A repeater box is required when more than 32 MCN485BB 8 8 ft RS485 cable used for back to Drops are Needed configurations Each repeater box is capable of supporting and 32 drops The Maximum size for an RS485 Network is 255 Each repeater box converter box and message count as one drop each Each 32 drop network has a wiring limitation on the baud rate data transmission rate 9600 baud 4,000 feet max 4800 baud 8,000 feet max 2400 baud 10,000 feet max 1200 baud 10,000 feet max No MCN485EOLTCB MCN485 RJ11 8 EOL terminator ferrite towards sign incl w cable ft 4 conductor RS485 cable ft 4 conductor RS485 cable MCNMNARJ11485 Modular Network Adaptor cable 1000 ft spool Box with 2 EOL terminators MNC485CB2EOLT ft 9 pin to pin type RS232 cable MCN485CB232A9 port DB25 to DB9 RS232 adapter be required by your computer Copyright 2002 Edwards Fieldstone Court Cheshire CT 06410 h 2 0 3 6 9 9 3 3 0 0 F x 2 0 3 6 9 9 3 1 0 8 CENTERS ANNUNCIATORS Center Connectivity Contact Closure Programmable Logic Controller Edwards Message Center can be activiated us a PLC There are two requirements The PLC must have an RS232 or RS485 commu MESSAGE CENTERS WIRING METHOD output The PLC must be capable of outputing an ASCII string through it communications output single Message Center connection use RS232 method For multiple Message Center opera use RS485 wiring method PLC can be used to send a complete message to or more Message Centers Or the PLC can acti a previously loaded message in one or more Centers A PLC can be used to monitor on a factory floor production line or pro control and translate to an output that sends a to or activates a pre loaded message in any Message Center MESSAGE CENTER WIRING METHOD No MCN485EOLTCB MCN485 RJ11 8 Termination ferrite towards sign incl w cable ft 4 conductor RS 485 cable ft 4 conductor RS 485 cable MCNMNARJ11485 Modular network adapter MCN485CB2EOLT MCN485CB232A9 ft spool of RS485 cable box w 2 EOL terminators ft 9 pin to 9 pin type RS232 Set internal message center jumper to RS485 TECHNICAL BULLETINS at www edwards signals com How to display text messages using a PLC Activating preloaded messages using a Activating messages using

Related Files