Edwards SB4U Analog Audible Detector Base Installation Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | edwards-sb4u-analog-audible-detector-base-installation-sheet-6723495081.pdf |
---|---|
Type | |
Size | 897.71 KB |
Downloads |
Text Preview
Analog Audible Detector Base Sheet FR Installation Sheet SB4U Analog Audible Detector Base adds an audible function to the listed compatible detectors The base operate as an independent local alarm or as part of a or system alarm with synchronized audible output output of this detector base is field configurable for output steady or temporal and output volume low dBA or high on the system supporting the device loop the base the state of the device it supports controlled and configured for other operating modes front panel programming or the configuration utility base uses the same address and programming label as detector it supports avoid accidental damage to the control panel all power before wiring the unit supervision requires the wire run to be broken at terminal Do not loop the signaling circuit field wires the terminals Always connect the base to a continuous voltage the output tone is set to steady or temporal rooms In sleeping areas use the high dBA output temporal tone settings However if the control panel is the three tone temporal evacuation signal then the dBA output and steady tone settings are permissible When using the AB4G SB box install a reinforcing at every knockout Reinforcing plates are included with box Remove the knockout first and then slide the plate into the plastic housing After the plate is in install the conduit connector and nut See Figure 1 the base is configured to produce a high dBA tone and is connected to a notification appliance that outputs a continuous 24 VDC signal If the appliance circuit outputs a temporal signal the tone setting on the base for steady install the base The unit default is for high dBA output To set the output to dBA cut the circuit board trace as marked on the back the PC board See Figure 3 The unit default is for temporal pattern output To set the to steady tone cut the circuit board trace as on the back of the PC board See Figure 3 Select and install a compatible electrical box and bring field wiring into the box the trim ring and secure using screws The trim ring included with the SB4U base See Figure 2 Make all wiring connections as shown in Figure 3 Attach the base plate to the electrical box using the provided with the electrical box Attach the trim ring to the base plate Align the marks on trim ring and base plate press the trim ring onto the plate and then rotate the trim ring until it locks into Attach the desired detector to the base Align the arrows the detector and trim ring press the detector into the and then rotate the detector until it locks into place Apply power and activate the unit to verify that it is properly 2013 UTC Fire Security All rights reserved 6 3101077 REV 05 REB 23JAN13 1 AB4G SB box installation Screw Nut Reinforcing plate Conduit connector AB4G SB electrical box tab Trim rings 2 Base installation in accordance with NFPA 72 and CAN ULC S524 Be to observe the polarity of the terminals on the terminal as shown in the diagram the wire run at each terminal Do not loop signaling field wires around terminals to the applicable technical reference manual for diagrams Shielded wire is required only in environments with very electrical noise When you use shielded cable follow recommendations connection to and from the base must be and must be insulated from ground Insulate shield using tape Class B wiring there is no shield connection to ground the last device 3 Output configuration and wiring diagram AUX RISER IN from power supply or previous base Volume setting default is high volume cut per item 4 for low Tone setting default is temporal pattern cut per item 4 for steady To configure output volume or tone cut the circuit board as AUX RISER OUT To next base or EOL relay SLC OUT to next intelligent addressable device SLC IN from intelligent addressable controller or previous device Detector Trim ring Screw Base plate Compatible electrical box 6 3101077 REV 05 REB 23JAN13 1 Operating current in mA RMS VDC VDC VDC dBA VFWR VFWR VFWR dBA Volts direct current regulated and filtered Volts full wave rectified VDC Low dBA 2 Sound level output dBA per CAN ULC S525 room per UL 464 1 dBA room per UL 268 2 For UL 464 applications low dBA settings are for private mode only For UL 268 applications the high setting must be used for 3 Audible directional characteristics degrees reference and 100 and 110 sound pressure level dBA dBA dBA axis and veritical axis reflect the same pattern 4 Sound pressure level per CAN ULC S525 dBA dBA 24 VDC 24 24 VDC 24 not change the factory applied finish voltage sounder settings level output pattern volume tone detectors electrical boxes size diameter from box including distance from wall mount humidity environment temperature range VDC or 24 VFWR Table 1 1.46 mA FWR 2.15 mA dBA pattern Table 2 Table 4 s on 0.5 s off 0.5 s on 0.5 s off s on 1.5 s off repeat cycle E PD FX PHD E PHD E HD V PS V PHS V HRD V HFD surface box for audible American 4 in square x in 64 mm deep box European 100 mm box to 18 AWG 0.75 to 2.5mm 16 and 18 AWG are preferred in 152 mm in 66 mm in 305 mm to 120 0 to 49 to 93 noncondensing to 140 to 60 information of rating American A Division of UTC Fire Security Corporation Inc Town Center Parkway Bradenton FL USA first two digits of the DATE MFG number on the product identification label are year of manufacture 24 DC or 24 FWR UL 268 UL 464 CAN ULC S525 and CSA C22.1 and CAN ULC S524 device is prohibited from being installed in a unit as defined in the National Building of Canada information contact information see www edwardsutcfs com 3101077 REV 05 REB 23JAN13 6 Fiche D Installation base audible analogique SB4U pour d est con ajouter une fonction audible aux d compatibles Elle peut fonctionner en tant qu locale ou comme partie d zone ou d syst de sorties audibles synchronis de la base selon le syst supportant la du dispositif peut suivre l du dispositif qu supporte peut contr et configur pour d modes de en programmant le panneau avant ou de configuration sortie de la base audible analogique SB4U peut sur place pour la tonalit de sortie st