EST 270141 R2[1] 0 MVM Multiple Voice Message Module Manual

File Preview
File Preview
Click below to download for free

Text Preview

Multiple Voice Message Module Manual MVMR MVMR RM MVMP RM MVMX 270141 Rev 2.0 SEP98 BY NOTICE 1994 1995 1995 1997 1998 Systems Technology Parkland Drive FL 34243 739 4300 1998 Edwards Systems Technology Inc manual and the products it describes are copyrighted by Systems Technology Inc EST You may not reproduce transcribe or transmit any part of this manual without written permission from EST manual contains proprietary information intended for distribution authorized persons or companies for the sole purpose of business with EST If you distribute any information in this manual to unauthorized persons you have violated distributor agreements and we may take legal action manual was designed and written by the EST Technical Documentation Department Sarasota HISTORY Reason for change Release programming kit and off line operation rack mounting information 100mA to 130mA per ECN 95 0379 change and added number of audio channels and 4 play options steps changes and clarified the Play Options selections time and date program options 1 1 4 5 6 6 and FCC Network Setup 7 Module Setup 7 Wiring 8 9 Up 9 B MVMR P to IRC 3 Wiring 11 B MVMR P to FCC PCPU Wiring 12 A MVMR P to FCC PCPU Wiring 13 and Indicators 14 15 Module Parameters 15 Database 15 Interface 15 Formatting 16 Attributes 16 17 Steps 17 Menus 19 Keys 19 Functions 20 Splicing Operators 25 Splicing Example 25 40 40 40 Program 41 and Troubleshooting 45 Parts 47 Manual Menu Flow Chart 48 Worksheet 49 Splicing Worksheet 50 Splicing Operators 50 Splicing Example 50 Worksheet 52 Manual information of liability content of this manual is proprietary in nature and is intended for distribution to authorized persons companies distributors others for the sole purpose of conducting business associated Edwards Systems Technology Inc The distribution of contained within this manual to unauthorized persons shall a violation of any distributor agreements and may result in of legal proceedings product has been designed to meet the requirements of NFPA 72 1996 Edition Underwriters Laboratories Inc Standard 7th Edition and Underwriters Laboratories of Canada Inc ULC S527 Installation in accordance with this manual codes and the instructions of the Authority Having is mandatory EST Inc shall not under any circumstances liable for any incidental or consequential damages arising from loss property or other damages or losses owing to the failure of EST Inc beyond the cost of repair or replacement of any defective EST Inc reserves the right to make product improvements change product specifications at any time every precaution has been taken during the preparation of this to ensure the accuracy of its contents EST assumes no for errors or omissions warning equipment can generate and radiate radio frequency energy If this is not installed in accordance with this manual it may cause to radio communications This equipment has been tested found to comply within the limits for Class A computing devices to Subpart B of Part 15 of the FCC Rules These rules are to provide reasonable protection against such interference this equipment is operated in a commercial environment of this equipment is likely to cause interference in which the user at his own expense is required to take whatever measures be required to correct the interference Manual Documentation Fire Protection Association NFPA Batterymarch Park Box 9101 MA 02269 9101 Electric Code Fire Alarm Code Laboratories Inc ULI Pfingsten Road IL 60062 2096 Actuated Signaling Boxes Detectors Single Multiple Station Closers Holders for Fire Protective Signaling Systems Detectors for Fire Protective Signaling Systems Detectors for Duct Applications Indicators for Fire Protective Signaling Systems Signaling Appliances Detectors for Fire Protective Signaling Systems for Control Units for Fire Protective Signaling Systems Supplies for Fire Protective Signaling Systems Signaling Appliances Signaling Appliances Laboratories of Canada ULC Crouse Road Ontario M1R 3A9 for Control Units for Fire Alarm Systems for the Installation of Fire Alarm Systems for the Inspection and Testing of Fire Alarm Systems for the Verification of Fire Alarm Systems of state and local building codes of the Authority Having Jurisdiction 70 72 38 228 268 268A 346 464 521 864 1481 1638 1971 S527 S524 S536 S537 Manual Record and Playback Rack Mounted P N 240427 and Playback P N 240372 Recorded Messages Record and Playback P N Factory Recorded Messages Record and Playback Mounted P N 240426 Memory Board P N 240373 Battery Module P N 130280 Firmware revision 1.4 or greater supports multiple sample rates firmware revisions do not MVMR P Multiple Voice Message Modules are microprocessor one three channel audio message playback components for use the IRC 3 or FCC Emergency Voice Communication Systems RECORDING LEVEL MVM TO EM models can simultaneously playback three different pre recorded Plug in Model MVMX memory boards 2 max extend the run time by 16 minutes for 3 channel 13 minutes for 2 and 11 minutes for 1 channel for a maximum of 32 minutes 26 minutes 2 channel and 23 minutes 1 channel module is available in two versions the MVMP and the MVMR MVMP contains a two minute library of up to 7 factory recorded with alert and alarm tones on an EPROM Library Chip The is capable of 3 channel mode only With plug in memory installed the MVMP can record edit splice and playback up to messages having a total length of 16 minutes 3 channel with one memory expansion board or 32 minutes 3 channel with two expansion boards installed Rack mounted versions MVMP and MVMR RM are designed to be used in conjunction with the Rack Mount Option Faceplate when installing the MVMR P in CB31 or CB45 enclosures Manual MVMR module has an onboard 86 seconds 1 channel 100 2 channel or 120 seconds 3 channel record and playback capacity with no MVMX memory boards installed The can add 11 minutes 1 channel 13 minutes 2 channel or 16 3 channel additional record and playback message with one memory expansion board or 23 minutes 1 channel 26 2 channel or 32 minutes 3 channel with two memory boards installed MVMR also has the option for choosing the record playback rate Higher sample rates provide improved audio quality sample rates are achieved by sacrificing audio channels When MVMR is configured for 3 channels the sample rate is 36 kBits per for 2 channels the sample rate is 43 kBits per second and for channel the sample rate is 50 kBits per second Once a sample rate is selected it can not be c

Related Files