EST 270729 EST3 Version 3 72 Release Notes

File Preview
File Preview
Click below to download for free

File Data

Name est-270729-est3-version-3-72-release-notes-2943057816.pdf
Type PDF
Size 987.89 KB
Downloads

Text Preview

GE Version 3.72 Release Introduction 1 Operating system compatibility 2 New software versions 2 Overview of changes 2 Software revisions and compatibility 3 New in 3 SDU version 3.71 6 New in 3 SDU version 3.72 8 V3.71 Microcode updates 9 Installation and upgrade notes 9 Running the 3 SDU 9 Microcode panel upgrade instructions 10 3 SDU Help 13 Language support 13 Known issues 15 Introduction release notes contain a summary of the changes made for versions 3.71 and of EST3 If you have already updated to version 3.71 you can bypass information that version The notes may also include information that was not available for in the documentation or Help system at publication time Please read these notes in their entirety before attempting to install your new of the 3 SDU The topic Microcode panel upgrade instructions 2009 GE Security Inc of 16 270729 ISS 03MAR09 detailed instructions on upgrading systems using the network download The use of in a model number may be used to indicate several generations of product For example 3 CPUx represents the 3 CPU 3 CPU1 and 3 CPU3 Operating system compatibility 3 SDU V3.72 is compatible with these operating systems Microsoft Windows Windows XP Service Pack 3 and Windows Vista For an important note Windows Vista please refer to the issues section of this New software versions 1 New EST3 software and microcode versions microcode microcode microcode microcode microcode new installation kit update kit microcode microcode microcode Overview of changes What s new in version 3.71 Removed CHECK IN Groups Removed the EMERGENCY device type Updated SDU Help of 16 Version 3.72 Release Notes Changed the initial default setting for K5 on RZB12 6 3 Fixed issue with fire phone call in event on RZB12 6 3 Fixed issue preventing TAP location substitution string transmission by slot when deleted Fixed issue that prevented a ZA 95 amplifier from being removed from the second Fixed issue with passwords being deleted from imported projects in version 3.70 Fixed issue with User Changed Pseudo Point Color option Fixed issue that caused an error when opening a project with the Verify Project Repair option checked fixes for rule commands A1TST and other trouble tests which showed devices as being invalid during rules compile What s new in version 3.72 Fixed missing Location Text in pager messages Fixed ASU Configuration exit changing devices types of some switches pseudo and IDC zones to LOCAL RELAY the maximum number of 3 MODCOM modules allowed the maximum number of AND groups allowed Software revisions and compatibility LRM compatible versions stay up to date you should upgrade to 3 SDU version 3.72 There is no need to 3 CPUx application code or bootloader code 2 3 SDU version 3.72 software compatibility Version 3.72 Release Notes of 16 Chip Chip Chip Chip Chip Chip Chip Chip Chip Chip Chip Chip of 16 Version 3.72 Release Notes Chip Oldest version still compatible with the current version of 3 SDU Version 1.12 required for standalone mode disabled feature To obtain V1.12 a deviation version for part number 190151 through Technical Support 3 CPUx V3.7 microcode cannot reside on the same network as earlier 3 CPUx To use V3.7 all panels must be upgraded to V3.7 Networks with microcode version 1.4 or later can be upgraded with the 3 SDU by using network download function See the topic Version 3.71 panel instructions The 3 CPU3 is 100 percent backward compatible with and can be installed on the network as 3 CPU1 and 3 CPU The 3 CPU3 and 3 CPU1 require at least 1.41 microcode 3 FTCU firmware comes in two noninterchangeable forms Part 190254 cannot be to update Part 190156 and vice versa 3 SDU database compatibility V3.72 can be used to generate databases for the LRMs listed in the following 3 LRM microcode supported by 3 SDU V3.72 supported microcode versions V3.0 V3.1 V3.41 V3.0 V3.1 V3.41 V3.6 V3.7 V3.71 V3.0 V3.4 V1.52 V2.0 V3.0 V3.1 V3.2 V3.41 V3.5 V3.6 V3.7 V3.6 V3.1 V3.11 V3.12 V3.6 V3.5 V3.6 V2.1 V3.32 Version 3.72 Release Notes of 16 supported microcode versions V2.1 V3.32 V3.6 V3.7 V3.71 V1.4 V1.5 V1.6 V1.7 V1.1 V1.2 V1.3 V1.4 V1.5 V1.6 Latest compatible versions following table identifies the most recent version of LRM microcode that is with each version of 3 CPU microcode We recommend that you use the compatible version of LRM microcode 4 LRM and 3 CPU microcode compatibility V2.0 microcode versions V2.1 V2.1 V2.1 V2.1 V3.41 V3.41 V3.41 V3.41 V3.41 V3.6 V3.12 V3.12 V3.12 V3.6 V3.32 V3.32 V3.32 V3.32 V3.32 V3.32 V3.32 V3.32 V3.32 V3.32 V3.32 V3.32 V3.32 V3.32 V3.32 V3.32 V3.6 V3.32 V3.32 V3.6 New in 3 SDU version 3.71 Removal of CHECK IN group and EMERGENCY device type you attempt to open a project containing CHECK IN groups and EMERGENCY types a warning message appears of 16 Version 3.72 Release Notes 1 Check In group warning message Yes removes these objects from your project You will have to change any that use theses objects This affects only Check in groups and Emergency types report is displayed showing all the CHECK IN groups removed All EMERGENCY types will be changed to MONITOR device types Use this information to your rules and devices 2 Unsupported Devices Groups sample report Version 3.72 Release Notes of 16

Related Files