EST 270844 R1[1] 0 IRC3 System Compatibility Manual
File Preview
Click below to download for free
Click below to download for free
File Data
Name | est-270844-r1-1-0-irc3-system-compatibility-manual-8401376295.pdf |
---|---|
Type | |
Size | 820.72 KB |
Downloads |
Text Preview
270844 14JUL97 Compatibility Manual BY NOTICE Systems Technology Parkland Drive FL 34243 739 4300 1997 Edwards Systems Technology Inc manual and the products it describes are copyrighted by Systems Technology Inc EST You may not reproduce transcribe or transmit any part of this manual without written permission from EST manual contains proprietary information intended for distribution authorized persons or companies for the sole purpose of business with Edwards Systems Technology Inc If you any information contained in this manual to unauthorized you have violated all distributor agreements and we may legal action manual was designed and written by the EST Technical Documentation Department Sarasota Compatibility List Compatibility List 9 AUS Compatibility Listings Listing Listing System Compatibility Manual information of liability content of this manual is proprietary in nature and is intended for distribution to authorized persons companies distributors others for the sole purpose of conducting business associated Edwards Systems Technology Inc The distribution of contained within this manual to unauthorized persons shall a violation of any distributor agreements and may result in of legal proceedings product has been designed to meet the requirements of NFPA 72 1996 Edition Underwriters Laboratories Inc Standard 7th Edition and Underwriters Laboratories of Canada Inc ULC S527 Installation in accordance with this manual codes and the instructions of the Authority Having is mandatory EST Inc shall not under any circumstances liable for any incidental or consequential damages arising from loss property or other damages or losses owing to the failure of EST Inc beyond the cost of repair or replacement of any defective EST Inc reserves the right to make product improvements change product specifications at any time every precaution has been taken during the preparation of this to ensure the accuracy of its contents EST assumes no for errors or omissions System Compatibility Manual Documentation Fire Protection Association NFPA Batterymarch Park Box 9101 MA 02269 9101 Electric Code Fire Alarm Code Laboratories Inc ULI Pfingsten Road IL 60062 2096 Actuated Signaling Boxes Detectors Single Multiple Station Closers Holders for Fire Protective Signaling Systems Detectors for Fire Protective Signaling Systems Detectors for Duct Applications Indicators for Fire Protective Signaling Systems Signaling Appliances Detectors for Fire Protective Signaling Systems for Control Units for Fire Protective Signaling Systems Supplies for Fire Protective Signaling Systems Signaling Appliances Signaling Appliances Laboratories of Canada ULC Crouse Road Ontario M1R 3A9 for Control Units for Fire Alarm Systems for the Installation of Fire Alarm Systems for the Inspection and Testing of Fire Alarm Systems for the Verification of Fire Alarm Systems of state and local building codes of the Authority Having Jurisdiction 70 72 38 228 268 268A 346 464 521 864 1481 1638 1971 S527 S524 S536 S537 System Compatibility Manual history 1997 System Compatibility Manual P N 270844 Status For Change Release System Compatibility Manual Compatibility List devices listed in this section are for use in the USA ONLY Devices SIGA Data Circuit ULI Panel Compatibility Controller Card Signature Series Devices Smoke Detector Smoke Detector Photoelectric Smoke 135 F 57 Fixed Detector Ionization Photoelectric Smoke 135 F 57 Temperature Detector F 57 Fixed Temperature Detector 135 F 57 Fixed Temperature 15 Heat Detector Input Signal Module Input Signal Module 2 addresses per module Input Module Input Module 2 addresses per module Relay Module Module Waterflow Tamper Module 2 addresses per module Module 2 addresses per module ULI Control Unit Compatibility Specifications SIGA UM Module Smoke VDC mV Detector B mA 22.3 Detector D mA 22.3 ULI Device SIGA UM Compatibility Initiating Devices Devices IDC Zone Smoke System Compatibility ULI Device SIGA UM Compatibility Initiating Devices Sensor 1451 Sensor 2451 Smoke Smoke Smoke Devices IDC Zone Manufacturer of 2 wire smoke detectors installed on a single must be identical Do NOT mix Edwards and System Sensor on an IDC ULI Compatibility 4 Wire Initiating Devices to the SIGA UM Installation Sheet P N 387024 for complete information Smoke Detector with 6251B 003 relay base Smoke Detector with 6251B 003 relay base Duct Smoke Detector with 6251B 003 relay base 6260A 100 Duct Smoke Detector with 6251B 003 relay base 6260A housing ULI Listed Compatible Devices for the ZAS 1 S Ionization Detector Photoelectric Detector Photoelectric Heat Detector Fixed Temperature Heat Detector Fixed R O R Heat Detector Sensor Base European BESA Style Sensor Base North American Style Sensor Base Adapter Plate w Sounder Housing Monitor Module Mini Monitor Module Control Module Isolator Module System Compatibility per Zone ULI Device ZBA4 2 ZB0 8 ZB8 2 ZB8 5 ZB8 5 3 ZB8 8 ZR8 2 RZB12 6 RZB12 6 3 Housing Head Housing Head Devices Smoke w Base Smoke Duct Smoke Duct Detector Smoke w Base Smoke Detector w Base Smoke Detector Smoke Smoke Detector Duct Smoke w Base Duct Detector w Base