EST EST2 v1 0 Installation Sheets
File Preview
Click below to download for free
Click below to download for free
File Data
Name | est-est2-v1-0-installation-sheets-3207456981.pdf |
---|---|
Type | |
Size | 3.61 MB |
Downloads |
Text Preview
EST2 Sheets 3100056 Rev 1.0 30NOV00 Manuals Online BY NOTICE Systems Technology Parkland Drive FL 34243 739 4300 2000 Edwards Systems Technology Inc manual is copyrighted by Edwards Systems Technology EST You may not reproduce translate transcribe or any part of this manual without express written from EST manual was designed and written by the EST Technical Documentation Department Sarasota HISTORY for change release Manuals Online sheet title and 2 6ANN D Remote Annunciator Cabinet Doors Audio Control Module Remote Alphanumeric Display Annunciator Central Processor Unit Semi flush Trim Kit Data Line Monitor Isolator Module Liquid Crystal Display Expander Loop Module Semi flush Trim Kit Life Safety Remote Annunciator Main Controller Module Network Main Controller Module Microphone Module Primary Power Supply Primary Power Supply Remote Network Control Module Smoke Power Converter Module Firefighter Telephone Module Semi flush Mount Wallbox Long Wallbox Outer Door and Inner Door 2 WB3DF Dead Front Door Double wide Wallbox Outer Door and Inner Door 2 WB7DF Dead Front Door Outer Door and Inner Door Outer Door and Inner Door Surface Mount Wallbox and 10ANN B S Remote Annunciator Cabinet Wallboxes Bell Coder SMDN 2 CMDN C 2 SMDN C Enclosure Installation Component Installation Sheets Manuals Online sheet title Dialer Panel LED Switch Modules Isolator 232 card Annunciator Switch Panel Printer Programming Port LSRA PROG Programming Port Remote Equipment Cabinet Door Remote Equipment Cabinet Strip Printer Series Remote Annunciator Enclosures Annunciator Controller Microphone Remote Annunciator Display Module Remote Annunciator Lamp and Switch Module Audio Amplifiers Auxiliary Power Supply Remote Annunciator Input Receiver Module Remote Annunciator Lamp Module Remote Annunciator Relay Module Remote Annunciator Lamp and Switch Module Component Installation Sheets Manuals Online this manual manual contains copies of the EST2 installation sheets The are arranged in alphabetical order by title The part listed in Content is the installation sheet part number EST2 library library of related documents supports the EST2 product line is a complete list of the EST2 library technical writers constantly update the information in this Your comments during our training classes technical phone calls and field trips improve this document Installation and Service Manual P N 270186 Network Site Manual P N 270895 Network Supplement Manual P N 270894 System Operations Manual P N 270188 System Programming Manual P N 270187 Installation Sheets P N 3100056 Help P N180902 documents Signature Series Intelligent Smoke and Heat Detectors Bulletin P N 270145 provides instructions and for various arrays of smoke and heat detectors Signature Series Component Installation Manual P N supports the installation of the Signature Series and modules Serial Number Log Book P N 270267 provides a means for recording the serial number of each device installed in the fire alarm system SAN Annunciator Installation Guide P N 250084 supports SAN annunciators mentioned in this manual EST Speaker Application Guide P N 85000 0033 provides about the placement and layout of speakers for fire signaling and emergency voice communications EST Strobe Applications Guide P N 85000 0049 provides for the placement and layout of strobes for fire alarm Microline 182 Turbo Printer Handbook by Okidata all the necessary information for the maintenance and of the PT1 S Form Printer The Okidata handbook with the Form Printer Component Installation Sheets Manuals Online Component Installation Sheets Manuals Online DESCRIPTION DIAGRAM 2 3ANN D is a set consisting of an outer door and an door The outer door and the inner door mount on remote annunciator wallbox The outer door has a viewing window The inner door provides space for a liquid crystal display and three modules 2 6ANN D is a set consisting of an outer door and an door The outer door and the inner door mount on remote annunciator wallbox The outer door has a viewing window The inner door provides space for a liquid crystal display and six modules Install the outer door Align the outer door mounting holes with the wallbox mounting studs Mount the outer door with the washers and provided Door Door Door Door Detail A A mounting stud door mounting hole SHEET and 2 6ANN D Annunciator Cabinet Doors SHEET P N 387478 NAME 387478 CDR LEVEL 2.0 BY K Patterson 30MAR00 BY B Graham SYSTEMS TECHNOLOGY INC FL 941 739 4300 FAX 941 753 1806 CT 203 699 3000 FAX 203 699 3075 SOUND CANADA 519 376 2430 FAX 519 376 7258 CANADA 905 270 1711 FAX 905 270 9553 Manuals Online the inner door the semi flush mount wallbox the surface mount wallbox Align the inner door mounting holes with the three Align the inner door mounting holes with the three door mounting studs on the wallbox door mounting holes in the wallbox Secure the inner door to the wallbox with the Secure the inner door to the wallbox with the and nuts provided provided Detail B B mounting stud door mounting hole mounting hole door mounting hole the ground strap the ground strap to the outer door ground with the nut and washer provided a wire connected to earth ground through a in the wallbox the ground strap and the earth ground wire the wallbox with the nut and washer provided strap Detail C lug door lug knockout ground wire C strap lug door lug knockout ground wire Manuals Online REV 2.0 Page 2 of 2 DESCRIPTION Audio Control Module is a dual channel electronics package which with the paging microphone operator interface 2 MIC and firefighter telephone 2 TEL Two integral tone generators provide and evacuation signaling Two auxiliary pre amp level 1 V inputs pre recorded messages or other external sources Each of the audio output channels has a Class B or Class A pre amp level 1 output to feed the audio amplifiers requirements with 2 MIC with 2 TEL with 2 MIC with 2 TEL Vdc mA mA mA mA response Hz to 4 kHz Audio Control Module mounts on the rear of the enclosure and terminals for the external audio inputs two audio risers and data power to cabinets before installing or removing Failure to do so may result in serious injury or loss of configuration load resistance capacitance wire size inputs impedance level output dc output ac wire size Vrms 3 channels Class B Style Y or A Style Z SIGA AAxx amplifiers F AWG 1.5 mm ele