EST EST3 - SDU V3 71 Automatically Changes Device Types Tech Facts Bulletin

File Preview
File Preview
Click below to download for free

Text Preview

E C H N I C A L S U P P O R T B U L L E T I N SDU V3.71 Automatically Device Types F N 0 9 0 1 0 0 1 I S S 0 4 F E B 0 9 identified an issue with SDU version 3.71 that impacts the operation and of new and existing systems that have been upgraded to this of the software This technical bulletin informs you of the issue and tells how to resolve it version 3.71 automatically changes the device type of some operator layer and 3 IDC8 4 card circuits to Local Relay when you click OK to close 3 ASU Configuration dialog box The following operator layer switches and 3 card circuits are affected Operator layer switches typically addresses 4 to 7 installed on all amplifiers to the 3 ASU including those in other cabinets Operator layer switches typically addresses 4 to 7 and operator layer LEDs addresses 129 and 130 installed on all 3 IDC8 4 cards if the 3 ASU in Cabinet 1 All 3 IDC8 4 card circuits typically addresses 3 to 6 if an operator layer is installed and addresses 3 to 8 600 and 601 if an operator layer is not installed if the 3 ASU is in Cabinet 1 determine if you have this issue open the Object Configuration table Objects and see if the device types for any of your operator layer or 3 IDC8 4 card circuits are set to Local Relay compile will generate errors for the operator layer switches because the type is not valid for the left side of the rule Depending on how your rules written rules compile may not generate errors for the 3 IDC8 4 card circuits 0901001 ISS 04FEB09 1 of 2 existing projects To fix operator layer switches and LEDs you must remove them from the then add them back with the same labels and switch configurations To fix 3 IDC8 4 cards with operator layer switches or LEDs you only have to the 3 IDC8 4 Configuration dialog box and then click OK To fix 3 IDC8 4 cards without operator switches or LEDs you must remove from the project and then add them back with the same labels and configurations the 3 IDC8 4 card circuits were members of any logic groups you must add back to their previous logic groups new projects configure the 3 ASU before you configure your operator layer and 3 IDC8 4 cards issue will be corrected in a pending deviated release of the SDU followed by full release support Town Center Parkway FL 34202 800 655 4497 866 226 2126 est techsupport ge com 0901001 ISS 04FEB09 2 of 2

Related Files