EDWARDS SYSTEMS TECHNOLOGY AND ANNUNCIATION Annunciators 3 LCDANN 3 6ANN 3 10ANN 3 EVXXX LCD Annuniator has 168 character display information important to the user first First and last display hands free LCD uses queues to sort events Variety of wallbox configurations the annunciator to the application Programmable LED flash rates Slide in labels customization for regional language easy Full line of driver boards for graphic annunciators EST3 system supports a full range of annunciator options cabinets are constructed from 16 gauge cold rolled The gray textured enamel finish of the annunciators comple any decor Both surface and semi flush mounting cabinet maximize mounting flexibility and esthetic appeal arrangements allow both LED and LCD annunciation to combine in a single enclosure Slide in labeling for LEDs switches provides designation flexibility for labeling in local For graphic annunciation EST3 offers LED driver perfectly suited to operate in most graphic annunciators EST3 remote annunciators when a compact system status is needed Annunciator configurations include LCD only LED only displays or combination LED and LCD display in single enclosure LCD display uses the 3 LCD Liquid crystal display module 3 LCD has eight lines of 21 characters on its LCD display the room needed to convey emergency information in a format 3 LCD always displays the last highest priority event even the user is viewing other message queues To give the message flexibility EST3 event messages can route to annunciators Routing can be initiated at a specific time change Messages need only display in areas having to to an event ANN LED display the full line of EST3 Control Display Modules event display Control Display modules install over any support module maximizing annunciator design A Lamptest feature can program to any spare control If a 3 LCD display is installed in the annunciator simply the Alarm Silence and Trouble Silence switches simultane to lamptest all LEDs SALES SARASOTA FL 941 739 4638 FAX 941 727 1214 CANADA SALES OWEN SOUND ON 519 376 2430 FAX 519 376 7258 SALES 905 270 1711 FAX 905 270 9553 CORPORATE HEADQUARTERS CHESHIRE CT U S MANUFACTURING PITTSFIELD ME 3 Manuals Online Sheet 85010 0069 1 of 4 DWARDS SYSTEMS TECHNOLOGY Information LCD Command Module Annunciator Comes with CPU LCD display and doors wallbox separately LCD Command Module Annunciator Comes with CPU LCD display and doors Order wallbox separately EN 54 certified only CE Position Base Annunciator Comes with two 3 ANNSM annunciator support modules a CPU display doors Order Display Control modules additional support modules wallbox separately Position Base Annunciator Comes with two 3 ANNSM annunciator support modules a CPU display doors Order Display Control modules additional support modules and wallbox separately certified only CE Position Base Annunciator Includes two 3 ANNSM annunciator support modules a CPU display and Order Display Control modules additional support modules and wallbox separately Position Base Annunciator Comes with two 3 ANNSM annunciator support modules a CPU display doors Order Display Control modules additional support modules and wallbox separately certified only CE CPU Support Module Crystal Display Module Filler Plate Red LED Display Module Yellow LED Display Module Green LED Display Module switches with 12 Red LED Display Control Module switches with 12 Yellow LED Display Control Module switches with 12 Green LED Display Control Module Red LED and 12 Yellow LED Display Module switches with one Green and one Yellow LED per switch Display Control Module switches with one Red and one Yellow LED per switch Display Control Module switches with two Yellow LEDs per switch Display Control Module groups of three switches Each switch with one LED LEDs provided Green Yellow Yellow groups of three switches Each switch with one LED LEDs provided Green Yellow Red Driver Module For EST Graphics Driver Module Assembly for Third party Graphics Supply for EST Graphics Supply Assembly c w 19 inch rail mounting chassis assembly space one 3 ANNCPU1 for Third party Graphics mounting extrusion 19 inch mounting Space for up to three 3 EVDVRA modules Ordering Information Number Command module flush mount LCD wallbox Command module surface mount LCD wallbox outer doors for RLCM B S position LED LCD flush mount wallbox position LED LCD surface mount wallbox position LED LCD flush mount wallbox position LED LCD surface mount wallbox Wt kg 1.7 1.7 2.85 2.85 4.8 4.8 45 2 36 22 12 12 12 12 12 12 12 12 12 12 12 12 12 12 22 1.2 12 Wt kg 1.2 1.2 9 2.7 2.7 2.7 2.7 Manuals Online 2 of 4 Sheet 85010 0069 3 SYSTEMS TECHNOLOGY ULC FM CE LPCB Space over 3 ANNCPU Spaces in terminal strip Pair 18 14 AWG mm ft 1524m any three panels non condensing 32 cid 176 120 cid 176 F A or Class B For a complete list of EST3 annunciator display and control modules please refer to EST literature sheet part number 85010 0055 Number Listings Space Format 24 Vdc Termination Size Wire Distance Humidity Rating Styles Wiring view 3 ANNCPU1 Field Wiring Shown Annunciator Field Wiring Manuals Online 3 Sheet 85010 0069 3 of 4 SYSTEMS TECHNOLOGY Specification Life Safety system shall incorporate annunciation of Alarm Trouble and Monitor operations Annunciation must through the use of both LED display strips complete with a to custom label each LED as to its function Where control switches must be provided Switches with LEDs provide positive feed back to the operator of remote status An LCD display with basic common control and switches shall be provided The Common Control and LEDs provided as minimum will be Reset switch LED Alarm Silence switch and LED Panel Silence switch and Drill switch and LED It must be possible to add additional controls as required though the use of modular display units The LCD interface must provide the ability to display event messages of up to 42 characters The LCD must the emergency user hands free viewing of the first and last priority event The last highest priority event must always and update automatically System events must be placed in queues It shall be possible to view event types separately Having to scroll through a mixed of events types is not acceptable The total number of active by type must be displayed It must be possible to customize designations of all user interface LEDs and switches for local requirements It must be possible to route system event to specific annunciator locations Installation and Mounting Mounting Mounting SYSTEMS TECHNOLOGY is our intention to keep the product information current and accurate We can not cover specific applications or anticipate all requirements specifications are subject to change without notice For more information or questions relative to this Specification Sheet contact EST 1998 EST 4 of 4 Manuals Online Sheet 85010 0069 in U S A 3