EST iO500 Intelligent Life Safety System

File Preview
File Preview
Click below to download for free

File Data

Name est-io500-intelligent-life-safety-system-8715463920.pdf
Type PDF
Size 1.41 MB
Downloads

Text Preview

GE Fire Life Safety Panels EST iO500 intelligent life safety system offers the power of intelligent processing in a confi guration that delivers an solution for small to mid sized applications With detection electronic addressing automatic device map optional Ethernet connectivity and a full line of easily con gured option cards and modules this fl exible system offers offers that benefi ts building owners and contractors alike iO500 provides one Class A or Class B analog device loop that up to 250 device addresses A second 250 point loop may added to the iO500 to expand total system capacity to up to 500 addresses The panel includes four NACs that may be wired either Class A or Class B operation iO500 supports a wide range of accessories and related equip including Series intelligent modules detectors and bases remote annunciators cards that expand system capacity and extend system standard with one loop expandable to two that supports to 250 expandable to 500 intelligent devices each iO500 supports up to 125 detectors and up to 125 modules Signature Series intelligent modules and detectors Class B NACs or two Class A NACs C contacts for alarm and trouble Form A for supervisory addressing with automatic device mapping Ethernet port for diagnostics programming and a of system reports programmable switches with LEDs and custom labeling Genesis horn silence over two wires and UL 1971 strobe synchronization Class A wiring up to eight serial annunciators LCD LED only and interface use existing wiring for most retrofi t applications remotely or locally maintenance alert reporting and alarm verifi cation by point detector sensitivity x 20 character backlit LCD display Intelligent Safety System Sheet 85005 0130 Issue 1 to be used for installation purposes Page 1 of 8 iO500 life safety system is a powerful intelligent solution for small mid sized buildings Advanced analog technology delivers the ben of flexible system installation while a clean and easy to opera user interface makes panel operation and system maintenance and intuitive smart choice Series electronic addressing eliminates the tedium of set dipswitches and automatic device mapping ensures that each resides on the system at its correct location Meanwhile in programming allows the designer to customize the system precisely suit the needs of the building owner built right in fully programmable front panel switch LED combinations an added measure of flexibility Their slide in labels take the out of custom applications and present a clean finished for retrofits iO500 is particularly well suited to retrofit applications All are made over standard wiring no shielded cable This means that in most situations existing wiring can be to upgrade a legacy control panel to iO500 technology without expense or disruption of rewiring the entire building with a difference NACs are configurable to fully support the advanced signal technology of GE Genesis and Enhanced Integrity notification These devices offer precision synchronization of strobes UL 1971 standards For Genesis devices enabling this feature connected horns to be silenced while strobes on the same circuit continue to flash until the panel is reset remote annunciation annunciation is a strong suit of the iO500 Up to eight an can be installed on a single system Compatible annun include a range of LED and LCD models that provide zone or annunciation as well as common control capabilities iO500 also supports graphic annunciation with optional RA Annunicator interface modules Each interface provides control indicators and 32 LEDS Consult the Ordering section for details complete line of accessories iO500 life safety system is supported by a complete line of detectors modules and related equipment Consult the Information section for details front panel provides an easy to use operator interface as as all the necessary controls for front panel programming large back lit 80 character LCD displays system status event and programming prompts Large tactile control buttons are to see in low light conditions and bright multi color LEDs offer status indication buttons Silence arrow arrow arrow arrow a system reset the panel and remote annunciators during active trouble supervisory or alarm event and new event activations mode Silences active notification appliances Signal Silence a second time turns NACs back on a drill confirmation Pressing drill a second time off the drill function Disables or enables dialer set to modem only Disables or enables the alarm relay mode Moves the cursor to the left mode Toggles between programming selections mode Moves the cursor to the right mode Retrieves a programming option sub menu toggles between a programming option selections mode Advances to the previous event mode Moves the cursor up mode Advances to the next event mode Moves the cursor down mode Displays selected event details mode Retrieves a programming option sub or jumps to the Save function in the menu mode Enters the selected data into the system mode Exits the detailed information display mode Exits the current menu level mode Clears the current entry mode Enters the menu mode mode Exits menu mode a space such as a space between words mode Pressing a button once enters the number the button Pressing the button twice enters the value buttons can be programmed to control or operate device zone or Panel NAC The buttons can be labeled a slip in insert Sheet 85005 0130 Issue 1 to be used for installation purposes Page of 8 LEDs Operation Options Power Alarm LED On steady when there is an active alarm LED Flashes when there is a fault on a circuit or system component or when a is disabled LED On steady when there is an active event LED On when the panel has AC power LED Double flashes when there is a dis circuit alarm relay or remote annunciator Fault Yellow LED On steady during an active ground fault LED Flashes when performing an audible test Steady indicates a silent test LED On steady when there is an active event LED Indicates that detector needs servicing keys LED On steady indicates that NAC circuits turned off but the panel is still in alarm LED On steady indicates that the dialer disabled or that the alarm relay is enabled or when the dialer is set to modem only LED Indicates that the panel is in drill LED Indicates that the panel is resetting LED Indicates that the panel has been during an active trouble supervisory or event and indicates that new event activa have been acknowledged LED Programmable fail delay resound inhibit after turn on signal start start banner notification or French or Canada Off premise notification of an AC power failure is to 15 hours Delays the off premise notification of AC power failure by the time period selected NACs resound each time a device in the zone into alarm even if they were silenced Inhibits the NACs from turning on again after were silenced when a second device in the zone into alarm Panel reset is operational immediately minute Panel reset is inhibited for one minute Allows immediate silencing of signals from an condition using the Signal Silence button to 30 minutes Delays the silencing of signals from off normal condition by disabling the Signal button for the time period selected time for daytime sensitivity time for nighttime sensitivity MM DD YYYY

Related Files