SIGA CR Relay Module This module does not support conventional smoke voltage range 15.2 to 19.95 Vdc current 100 current 100 ratings pilot duty Vdc 2A Vac 0.5 A type Form C temperature range 32 to 120 0 to 49 humidity range 0 to 93 RH temperature range 4 to 140 20 to 60 High impact engineering polymer weight 5.1 oz 145 g electrical boxes American 2 1 2 in 64 mm deep 1 gang box 4 in square box 1 1 2 in 38 mm deep with cover instructions The SIGA CR is shipped from the factory as an unit it contains no user serviceable parts and not be disassembled install the module Verify that all field wiring is free of opens shorts and Make all wiring connections as shown in the wiring faults Write the address assigned to the module on the label and apply the label to the module Peel off the serial number label from the module and apply to the appropriate location in the serial number logbook Using the 4 24 x 1 2 in 13 mm self tapping screw mount the wall plate to the module Using the two 6 32 x 1 2 in 13 mm machine screws mount the module to the electrical box a 2 in 51 mm 1 gang box is used conduit can enter the box through only one knock out hole a 2 1 2 in 64 mm 1 gang box is used conduit can enter electrical box through one or both knock out holes Wire in accordance with NFPA 70 National Electrical description SIGA CR Control Relay Module is a component of the Series The SIGA CR is an addressable device used provide one Form C dry relay contact to control external door closers fans dampers etc or equipment The system firmware ensures that the relay is in the ON OFF state Upon command from the loop controller SIGA CR relay energizes TB2 6 and TB2 7 provide a closed relay connection TB2 7 and TB2 8 provide a open relay connection One device address is loop controller assigns an address to the SIGA CR A custom address can also be assigned to the via laptop computer No addressing switches are used LEDs provide visible indication of the status of the when the cover plate is removed SIGA CR can be mounted in a North American 2 1 2 in mm deep 1 gang box or a standard 4 in square box 1 1 2 38 mm deep with 1 gang cover The terminal blocks accept 14 16 or 18 AWG wire 2.5 1.5 1.0 or 0.75 sq mm 16 and 18 are preferred controller compatibility SIGA CR requires the Signature loop controller Code 8 dry contact output The SIGA CR is assigned personality code 8 which configures the as an output dry relay contact green LED flashes red LED flashes This module will not operate without electrical power As frequently cause power interruption we suggest you further safeguards with your local fire protection Sheet Control Relay Module P N 387023P REV 7.0 4 stripping guide in 6 mm 1 4 in about 6 mm from the ends of all wires that to the terminal block of the module Exposing more wire may cause a ground fault less wire may result in a faulty connection electrical box plate white diagram 5 LED Active LED IN Signature controller previous device 4 OUT next device Refer to the Signature loop controller installation sheet for specifications The SIGA CR must be installed within the same room as device it is controlling Maximum 12 AWG 2.5 sq mm wire minimum 18 AWG sq mm wire All wiring is power limited and supervised Supervised and power limited when connected to power source If non power limited then all power limited in box must use FPL FPLR or FPLP cable or per NEC Power limited marking must 387023P REV 7.0 4 Sheet Control Relay Module de commande Ce module ne supporte pas les d de fum de fonctionnement 15,2 19,95 Vcc de veille 100 de fonctionnement actif 100 des contacts fonction de commande V CC et 2A V CA et 0,5 A de relais C de temp de fonctionnement 0 49 32 120 d de fonctionnement 0 93 HR de temp de stockage 20 60 4 140 Polym technique avec r aux impacts la livraison 145 g 5,1 oz compatibles Am du Nord simple standard de 64 mm 2 1 2 po de carr standard de 10,16 cm 4 po de c et 38 mm 1 1 2 de profondeur avec couvercle simple Le SIGA CR est exp de l compl mont il ne aucune pi d par l et ne doit pas installer le module que le c du site ne comprend ni d connexion ni court circuits ni d de mise la terre les connexions indiqu dans le diagramme de c l assign au module sur l fournie et cette sur le module D du module l num de s et la recoller l appropri dans le des num de s Avec le vis autotaraudeuses de 4 24 x 1 2 po 13 mm fournie la plaque murale sur le module Avec les deux vis machine de 6 32 x 1 2 po 13 mm fournies le module dans la bo une bo standard simple de 51 mm 2 po est utilis le ne peut p dans la bo que une d seulement une bo simple standard de 64 mm 2 1 2 po est utilis le peut p dans la bo par une ou par les deux c doit conforme la NFPA 70 National Electric de produit Module de commande SIGA CR est un composant du s Signature Le SIGA CR est un dispositif adressable pour fournir un contact de relais sec C et commander des externes fermetures automatiques de portes ventilateurs etc ou l d Le microprogiciel du syst que le relais rest en position marche arr correct la du contr de boucle le relais SIGA CR est mis sous Les bornes TB2 6 et TB2 7 fournissent une connexion de normalement ferm Les bornes TB2 7 et TB2 8 fournissent connexion de relais normalement ouvert Une adresse de est n contr de boucle assigne automatiquement une adresse au ou une adresse particuli peut assign au module ordinateur portatif aucun commutateur d n utilis t DEL donnent une indication visuelle de l du module la plaque de protection est retir le t DEL vert clignote le t DEL rouge clignote SIGA CR peut mont dans une bo Am du Nord simple de 64 mm 2 1 2 po de profondeur ou dans une bo carr 10,16 cm 4 po de c et 38 mm 1 1 2 po de profondeur avec simple Les borniers acceptent des fils de 2,5 1,5 1,0 et de mm carr AWG 12 14 16 ou 18 Des fils de 1,0 et de 0,75 carr sont pr avec le contr du syst SIGA CR est uniquement compatible avec les contr de Signature de personnalit 8 sortie de contact sec Un code de de 8 est assign au CR lors de sa fabrication et le comme contact d

Related Files