Kidde Edwards Data Sheet K85001-0585 - Two-Wire SuperDuct Duct Smoke Detector

File Preview
File Preview
Click below to download for free

Text Preview

Two wire Duct Detector Series is slim feature rich alternative to bulky duct smoke Designed for easy installation and superb reliability represents the perfect balance of practical design and technology detectors feature a unique design that speeds instal and simplifies maintenance Removable dust filters confor coated circuit boards and optional water resistant gaskets contaminants away from components ensuring years of service When cleaning is required the assemblies apart easily and snap back together in seconds detectors use differential sensing to prevent gradual changes from triggering false alarms A rapid in environmental conditions such as smoke from a fire the detector to automatically signal an alarm condition but and debris accumulated over time does not change alarm detector assembly cover provides easy access to the sensor its wiring connections sample and exhaust tube and the smoke chamber itself Air enters the detector chamber through a sampling tube ordered separately extends into the duct and is directed back into the ventilation through an exhaust tube included The difference in air between the two tubes pulls the sampled air through the chamber When a sufficient amount of smoke is detected the sensing chamber the detector initiates an alarm Features Sensor PCB mounted photoelectric detector with onboard intelligence Environmental compensation with differential sensing for reli stable and drift free sensitivity Wide 0.79 to 2.46 obscuration ft smoke sensitivity assembly Less than 2 deep for easy installation and applications where is tight 4 to 158 20 to 70 operating range with 100 ft min 4,000 ft min air velocity rating assures reliability under harsh conditions Status LEDs remain visible through clear assembly cover Cover monitor switch for added security Standard sampling tube spacing for easy drop in migration other detectors Sampling tube can be installed with or without the cover in and can be rotated in 45 degree increments to ensure alignment with duct airflow On board Alarm Trouble and Dirty LEDs Magnet activated test switch One Form C auxiliary alarm relay for controlling ancillary equip e g HVAC controls Easy access to field connection terminals 1 of 4 D A T A S H E E T K85001 0585 to be used for installation purposes Issue 1 Catalog u Conventional InitiatingTechnology that saves livesfirealarmresources com SuperDuct two wire duct smoke detector is ideally suited to where early indication of combustion is required within confined space of ventilation ductwork Its primary purpose to provide early warning of an impending fire and to prevent from circulating throughout the building It is typically used detect smoke in the supply side of the HVAC system but can supervision of the return side as well premises relay smoke smoke Test Reset and Alarm Stations Labor saving Remote Test Reset stations alarm testing and indication from the of a remote location Tests can be quickly and safely without having climb to the roof Magnetically operated and one gang models are available SuperDuct detectors are also compat with EC LED remote alarm LEDs Duct detectors have specific limitations Duct detectors are not a for an open area smoke detector Duct detectors are not a substitute early warning detection or a replacement for a building regular fire detec system Smoke detectors are not designed to detect toxic gases which can up to hazardous levels in some fires These devices will not operate without power As fires frequently cause power interruptions Kidde suggests discuss further safeguards with your local fire protection specialist relay in 22.1 cm in 20.7 cm in 19.7 cm in cm in 7.82 cm detectors continually sample air flow in the HVAC duct initiate an alarm condition whenever smoke is detected An is activated when the quantity percent obscuration of products in that air sample exceeds the detector setting velocity in the duct as low as 100 ft min maintains adequate flow into the sensor smoke chamber through air holes in the air tube and discharges through the exhaust tube Su air sampling tubes must be installed with the inlet holes the airstream Sampling tubes may be rotated in 45 degree so that air holes can be aligned to allow the unit to be in virtually any angle relative to the airflow sampling tube may be installed from either the duct side of assembly or from inside the sensor compartment as preferred the installer The exhaust tube must be installed from the duct Sampling tubes may be rotated in 45 degree increments so air holes can be aligned to allow the unit to be mounted at any angle relative to the air flow sensors are engineered to operate optimally under the environmental conditions frequently found in HVAC duc Nonetheless before installing the detector test the duct velocity temperature and humidity to verify that it is within the range of the SuperDuct detector Consult the SuperDuct sheet for details in cm in cm in cm in cm in cm 2 of 4 D A T A S H E E T K85001 0585 to be used for installation purposes Issue 1 tube tube tube duct tube separately short circuit current 100 mA Compatibility 0.0 device device or SD TRM 2 1 listed alarm panel 8 8 1 not use looped wires under terminals 9and 7 or 10 and 8 wire run to provide supervision of connections short circuit 100 mA Compatibility 1.0 device device or SD TRM 2 1 listed alarm panel 8 8 1 not use looped wires under terminals 6and 10 or 5and 8 wire run to provide supervision of connections End of line resistor required on last controller only Value is determined by the alarm control panel No more than one remote test station can be connected at the same time is nonsupervised Maximum wire resistance is 10 ohms per wire Only the first detector to go into alarm operates its alarm relay Operation of the relay can be guaranteed if amanual initiating device or other detector on the circuit is activated sheet metal screw 2X environments the SD PH Protective Housing when installing SuperDuct in high humidity environments The SD PH is a housing that prevents condensation on the device insulating the detectors and providing circulated air from the HVAC duct The SD PH also adds a layer of protection physical damage to the unit Detector View tube tube holes SD PH is easy to install and service The hinged and transparent provides ready access to the detector while keeping its status visible at all times The SD PH Protective Housing is weatherized against outdoor but it is not intended for direct outdoor exposure 3 of 4 D A T A S H E E T K85001 0585 to be used for installation purposes Issue 1 that saves lives us kidde fire fs utc com Kidde com EngineeredSystems is a UTC brand Corporate Park Drive NC 27302 2016 United Technologies Corporation rights reserved detector size

Related Files