Kidde Edwards Data Sheet K85001-0611 - Analog Addressable Input-Output Modules

File Preview
File Preview
Click below to download for free

Text Preview

Intelligent FX 2WIRE FX IDC1A FX IDCWS FX ISO FX RLY FX IDC1B intelligent modules are engineered to deliver high perfor features superb reliability and unbeatable quality From of ancillary equipment to enhanced signaling functionality products add flexibility and powerful options to Kidde intel systems expressly for small buildings Kidde modules are ad devices that are uniquely identified on the system by of familiar rotary switches Once registered they share data update status information that determines how the system and how connected devices interact with one another to Kidde modules is ground fault detection so precise that actually pinpoints the specific module where the wiring problem occurred This saves hours of troubleshooting and wire trac And only Kidde provides this important feature Kidde family of intelligent modules also offers contractors and simple setup and installation while delivering options that full advantage of intelligent fire alarm processing With a mi in each device intelligence is distributed throughout system so that command decisions are made instantly at the module rather than bottlenecking at the control panel not only speeds event processing it also makes a more ro and reliable system so robust in fact that when upgrading a conventional panel to a Kidde intelligent system you can use existing wiring no twisted or shielded cable required Features Class A B Two Wire Module as an interface between conventional two wire smoke and the Kidde control panel Analog Class A Single Input Module to connect a normally open alarm supervisory or moni type dry contact initiating device circuit to the Kidde control Analog Dual Input Module two normally open alarm supervisory or monitor dry contact initiating device circuits to the Kidde control Analog Dual Input Waterflow Supervisory Module to connect normally open waterflow alarm and superviso initiating device circuits to the Kidde control panel For Class circuit operation Analog SLC Fault Isolator Module a Class A SLC from total collapse due to wire to wire circuits Analog NAC Module a supervised output circuit to a signal riser Analog Contact Relay Module one Form C dry relay contact and can be configured provide polarity reversal of its output Analog Single Input Mini Module a normally open alarm supervisory or monitor type contact initiating device circuit IDC to the Kidde control For Class B circuit operation 1 of 6 D A T A S H E E T K85001 0611 to be used for installation purposes Issue 1 Catalog u Small Building SolutionsTechnology that saves livesROTARY ADDRESSINGfirealarmresources com Addressing a screwdriver to adjust the two rotary switches on the front of module Set the TENS rotary switch 0 through 12 for the 10s and the ONES rotary switch for the 0 through 9 digit address 21 set TENS rotary switch to 2 set the ONES rotary switch to 1 to the Specifications Table for available address numbers operation provide a bicolor LED for status indication Green LED Normal Red LED Active box plate in a North American 4 inch square x 2 1 2 in 64 mm 2 gang box or a standard 4 in square box 1 1 2 in 38 mm A Single Input Module Class A Single Input Module is used to connect a normally alarm supervisory or monitor type dry contact initiating circuit IDC to the Kidde control panel The module is for Class A circuit operation module s device address is set using the two rotary switches on the front of the module One device address is re device can be preset for alarm or supervisory operation using slide switch located on the front of the module The module also be configured for other device types through front panel or the configuration utility D Class A next out out in in line voltage fault impedance environment temperature range electrical boxes size address NO device device circuit IDC circuit resistance circuit capacitance 20 V peak to peak k ohm to 120 0 to 49 to 93 RH noncondensing at 90 to 140 to 60 American 4 inch square x 2 1 2 64 mm deep 2 gang box 4 in square box 1 1 2 in 38 deep box 14 16 or 18 AWG wire 2.5 1.5 or 0.75 sq mm Sizes 16 and 18 are preferred to 64 64 point control panel to 127 1000 point control panel 25 per wire module will not operate without electrical power As fires cause power interruption you should discuss further with your local fire protection specialist module does not support conventional smoke detectors in accordance with NFPA 72 and CAN Be sure to observe the polarity of the as shown in the diagram 2 of 6 D A T A S H E E T K85001 0611 to be used for installation purposes Issue 1 A B Two Wire Module FX 2WIRE module interfaces between conventional two wire detectors and the Kidde control panel It monitors the and smoke detectors and signals the control panel of any or alarm conditions The module also regulates and super the 24 VDC input power FX 2WIRE is configured to operate as a two wire alarm device does not require alarm verification It can be set for two wire verified operation through front panel programming or the utility When using the alarm verification feature of the panel do not mix normally open contact initiating devices two wire conventional smoke detectors module recognizes the CleanMe signal from detectors that this feature device address is set using the two rotary switches located on front of the module One device address is required control not V V PWR next out out in in D Class A size B Class B kOhm EOLR for Bonly FX 2WIRE can be set for Class B or Class A operation using slide switch located on the front of the module This module cannot be used on a device loop with isolator or isolator bases line voltage panel input power power current detector current compatibility ID fault impedance environment temperature boxes address device circuit resistor value circuit resistance circuit capacitance 20.6 V peak to peak 350 Activated 350 to 28.3 VDC not resettable 17 mA Alarm 58 mA mA k ohm to 120 0 to 49 to 93 RH noncondensing at 90 to 140 to 60 American 4 inch square x in 64 mm deep 2 gang box 4 in square box 1 1 2 in 38 deep 14 16 or 18 AWG wire 2.5 1.5 or 0.75 sq mm Sizes 16 and 18 are preferred to 64 64 point control panel to 127 1000 point control panel k P N EOL 4.7 25 per wire Input Module FX IDC2B connects two normally open alarm supervisory monitor type dry contact initiating device circuits IDCs to the control panel This module is designed for Class B circuit device address is set using the two rotary switches located on front of the module Two consecutive addresses are required second address is automatically assigned one number higher the value set on the rotary switches FX IDC2B can be preset for alarm or supervisory operation the slide switch located on the front of the module It can be configured for other device types through front panel pro or the configuration utility line voltage fault impedance

Related Files