Kidde Edwards Data Sheet K85001-0612 - Intelligent Manual Pull Stations
File Preview
Click below to download for free
Click below to download for free
File Data
Name | kidde-edwards-data-sheet-k85001-0612-intelligent-manual-pull-stations-8103652947.pdf |
---|---|
Type | |
Size | 958.33 KB |
Downloads |
Text Preview
Intelligent Manual Stations FX 278 intelligent manual pull stations are engineered to deliver mance features superb reliability and unbeatable From control of ancillary equipment to enhanced signaling these products add flexibility and powerful options to intelligent systems expressly for small buildings Kidde pull stations are modules that are uniquely identified on the system by of familiar rotary switches Once registered they share data update status information that determines how the system and how connected devices interact with one another intelligent manual pull stations also offer contractors and simple setup and installation while delivering options take full advantage of intelligent fire alarm processing With a in each device intelligence is distributed through the system so that command decisions are made instantly at individual pull station rather than bottlenecking at the control not only speeds event processing it also makes a more ro and reliable system so robust in fact that when upgrading a conventional panel to a Kidde intelligent system you can use existing wiring no twisted or shielded cable required Features Traditional familiar appearance action models feature our familiar teardrop design with positive pull action and sturdy die cast metal body Single action GA and double action models action feature rugged Lexan housings with keyed reset Break glass operation up front visible glass rod on the FX 270 discourages tam Intelligent device with integral microprocessor decisions are made at the station allowing lower com speed while substantially improving control panel time Less sensitive to line noise and loop wiring twisted or shielded wire is not required ADA Compliant ADA requirements for manual pull stations Rotary Addressing easy to set wheels Diagnostic LEDs LEDs flashing GREEN shows normal polling flashing shows alarm state Designed for high ambient temperature operation in ambient temperatures up to 120 49 1 of 4 D A T A S H E E T K85001 0612 to be used for installation purposes Issue 1 Catalog u Intelligent Initiating DevicesTechnology that saves livesROTARY ADDRESSINGfirealarmresources com single input mini module mounted on the back of the unit fac installed supervises the station and sends an alarm signal to control panel when the switch is closed i e when the handle pulled device address is set using the two rotary switches located on back of the unit One device address is required pull station is configured for alarm latching operation When pull lever is activated an alarm signal is sent to the control and the alarm condition is latched at the pull station FX 270 pull station is a normally open dry contact initiating that requires one action by the user to initiate an alarm FX 278 pull station is a normally open dry contact initiating that requires two actions by the user to initiate an alarm the upper door marked LIFT THEN PULL HANDLE must be to access the alarm handle Second the alarm handle must pulled to initiate an alarm Addressing a screwdriver to adjust the two rotary switches on the front of module Set the TENS rotary switch 0 through 12 for the 10s and the ONES rotary switch for the 0 through 9 digit screwdriver here 6 5 9 in a North American 2 1 2 in 64 mm deep 1 gang box or 4 in square box 1 1 2 in 38 mm deep box with 1 gang Single Action Pull Station box I F I F rod lever address 21 set TENS rotary switch to 2 set the ONES rotary switch to 1 to the Specifications Table for available address numbers Double Action Pull Station next 2 of 4 Refer to the control panel technical reference manual for wiring All wiring is power limited and supervised rod release D A T A S H E E T K85001 0612 to be used for installation purposes Issue 1 line voltage environment temperature range electrical boxes size address 20 V peak to peak to 120 0 to 49 to 93 RH noncondensing at 90 32 to 140 to 60 American 2 1 2 in 64 mm deep 1 gang box 4 in square box 1 1 2 in 38 mm deep box with 1 gang cover 14 16 or 18 AWG wire 2.5 1.5 1.0 or 0.75 sq mm Sizes 16 and 18 AWG are preferred to 64 64 point SLC to 125 250 point control panel Information Action Fire Pull Station Kidde Addressable Action Fire Pull Station Kidde Addressable Wt lbs kg 0.5 pull stations will not operate without electrical power As fires cause power interruption you should discuss further with your local fire protection specialist in accordance with NFPA 72 and CAN ULC S524 Be sure to the polarity of the wires as shown in the diagram 3 of 4 D A T A S H E E T K85001 0612 to be used for installation purposes Issue 1 that saves lives us kidde fire fs utc com www kiddefx kidde com is a UTC brand Corporate Park Drive NC 27302 2016 United Technologies Corporation rights reserved 4 of 4 D A T A S H E E T K85001 0612 to be used for installation purposes Issue 1