Kidde Edwards Data Sheet K85001-0624 - Hazardous Location Strobes
File Preview
Click below to download for free
Click below to download for free
File Data
Name | kidde-edwards-data-sheet-k85001-0624-hazardous-location-strobes-2716845930.pdf |
---|---|
Type | |
Size | 901.00 KB |
Downloads |
Text Preview
Hazardous Strobes Features UL 1971 listed and ADA compliant for the hearing impaired Negligible in rush current Approved for fire alarm applications Wall ceiling or pendant mount Diode polarized for use in electronically supervised circuits High impact glass dome 1 Hertz flash rate 65 flashes per minute Synchronized with external module 60 cd wall or 125 cd ceiling per UL 1971 Factory sealed no external seals required Quick connect threads onto mounting module for easy instal Epoxy powder coat for corrosion resistance cUL listed to CAN ULC S526 07 and UL 1638 for indoor and applications hazardous location strobes are life safety signaling designed for installation in hazardous environments specifications and state of the art technology provide for visual output and low maintenance The 116DEGEX FJ has in rush current pendant wall or ceiling mounted the 116DEGEX FJ meets exceeds the requirements of UL 1971 Signaling Appliance for Hearing Impaired 116DEGEX FJ is intended for indoor use in UL 1971 signal for the hearing impaired listed compatible fire alarm The strobe flashes a 360 degree beam of light ap at 1 Hertz 65 times per minute with a UL 1971 125 ceiling and 60 cd wall light output With the guard installed strobe flashes a beam with an output of 86 cd ceiling and cd wall The strobe is also UL 1638 visual signal appliance mode listed with dome guard installed for both indoor and use and other applications requiring electrical supervision the signaling circuit field wiring The 116 Class strobes are cUL to Canandian Standard ULC S526 07 Visual Signal Device Fire Alarm Systems suitable for indoor and outdoor applica The strobe features an enhanced synchronization circuit to with the latest requirements of UL 1971 and CAN ULC Synchronized operation requires a separately installed control module See Ordering Information for assembled with one of the three available mounting op the 116DEGEX FJ is UL Listed for use in Class I Division 1 C and D Class I Division 2 Groups A B C and D Class Division 1 Group E F and G Class II Division 2 Group F and and Class III Division 1 and 2 hazardous locations The strobe also cUL Listed as a Type 3R and 4X enclosure 1 of 4 D A T A S H E E T K85001 0624 to be used for installation purposes Issue 1 Catalog u Notification AppliancesTechnology that saves livesfirealarmresources com hazardous location strobes are designed for use in Kidde fire alarm systems and other applications requir electrical supervision of signaling circuit field wiring strobes are suitable for many locations including mines flour mills tankers refineries laboratories and other ap where environmental hazards may be present 116DE strobes are particularly well suited in areas of high noise where standard bells or horns are not satisfactory pendant wall or ceiling mounted 116DEGEX FJ strobes cUL listed to CAN ULC S526 07 for indoor and outdoor ap and UL 1971 Listed ADA compliant for indoor visual applications in non sleeping areas Power Previous to activate signal DC Polarity of circuit shown in supervisory state signal inactive Reverse circuit Electrical supervision requires wire run to be broken at each device Device for constant input voltage Do not connect to or pulsating voltage re with to its modular design the 116DEGEX FJ for pendant ceiling or wall mounting the ordering information table for available modules 116EX P conduit 116EX C conduit wall mounted conduit 116EX B hub 9 16 mm 7 16 mm mm 3 4 mm 102 mm 79 mm screws 1 16 mm 13 16 mm screw s mm 3 4 mm 1 4 mm 1 4 mm series housing and globe with guard 3 4 mm 102 mm 8 mm de mm 3 4 mm mm 2 of 4 D A T A S H E E T K85001 0624 to be used for installation purposes Issue 1 Output Candela Light Output for Wall Bracket Mount Plane degree angle at side of globe dome guard shown output readings without optional dome installed UL Required CD for 60 Rating Candela Light Output for Ceiling Mount Y Planes degree angle at bottom of globe dome guard shown output readings without optional dome installed 90 UL Required CD for 125 Rating 3 of 4 D A T A S H E E T K85001 0624 to be used for installation purposes Issue 1 that saves lives us kidde fire fs utc com Kidde com EngineeredSystems is a UTC brand Corporate Park Drive NC 27302 2016 United Technologies Corporation rights reserved strobe intensity Rate Listings Listed Hazardous Compliance Sources Ratings Range Current RMS Temperature Color Type Temperatures ceiling or wall 1971 indoor and ULC S526 07 indoor outdoor cd ceiling 60 cd wall Hertz 65 fpm I Division 1 Groups C D Division 2 Groups A B C D II Division 1 Groups E F G Division 2 Groups F G III Divisions 1 2 1971 listed signaling appliance for the hearing impaired non sleeping areas only VM and VS Series life safety systems FX Series fire alarm panels Moduels GSA CC1S GSA MCC1S SIGA CC2A EG1M RM Power supplies MIRBPS6A MIRBPS10A APS10A 3R Type 4X cUL listed 33 Vdc 16 33VFWR 24 Vdc regulated 0.683A 24 VFWR 40 to 150 40 to 66 clear nominal white flash powder coat epoxy lbs 8.2 kg Wire I Div 2 A B I Div 2 C D II Div 1 E F G Class III II Div 2 F G III 104 167 260 131 194 260 149 221 260 85 85 85 120 120 135 135 160 135 Information Strobe Diode Polarized bracket mounting elbow mounting module mounting module 3 4 19 mm NPT Guard Globe Wt lbs 8.2 4 of 4 D A T A S H E E T K85001 0624 to be used for installation purposes Issue 1