Ceiling Speakers GC Series Genesis line of ceiling life safety and emergency communica speakers and speaker strobes combine high performance with a low profile design to deliver a life safety signal solu that as versatile as it is effective While they are designed to inconspicuously overhead these devices are also rated for applications speaker strobes are available in high and low candela which feature 15 to 95 or 95 to 177 cd output see order information Ceiling speakers feature W to 2 W operation allows devices to be easily fine tuned to achieve maximum in exchange for the lowest possible system overhead output and wattage tap settings are selectable with conven switches Settings remain clearly visible even after installation yet they are locked in place to prevent unauthorized after installation fidelity models meet the NPFA 520 Hz requirements for newly commercial sleeping areas They also produce crisp voice audio output that is highly intelligible over large areas low profile appliances feature textured housings in architec neutral white or eye catching life safety red Optional ALERT FIRE markings make them ideal for applications that require between life safety and mass notification alerts Specifications Section for listings details Features High Fidelity 520 Hz speaker models available frequency output meets NFPA standards for newly con commercial sleeping areas increases sound fidelity audio intelligibility Field configurable no need to remove the device Select 1 or 2 watt operation 15 30 75 95 cd and 95 115 150 177 cd models available Switch settings remain visible even after the unit is installed Ideal for Mass Notification applications amber lens models available with optional ALERT markings Unique low profile design 30 per cent slimmer profile than comparable signals Available with white or red housings Unparalleled performance loud 90 dBA output ensures clear crisp audio Precision strobe timing meets UL synchronization standards 25 VRMS and 70 VRMS models available Easy to install Fits all standard 4 inch square electrical boxes with plenty of for extra wire no extension ring or trim plate needed 18 12 AWG terminals ideal for long runs existing wiring Approved for public and private mode applications UL 1971 listed as signaling devices for the hearing impaired UL 1638 listed as protective visual signaling appliances UL 1480 listed as life safety speaker UL ULC listed for ceiling or wall use 1 of 6 D A T A S H E E T K85001 0641 to be used for installation purposes Issue 1 Catalog u Speakers TelephonesTechnology that saves livesfirealarmresources com Application strobes are UL 1971 or 1638 listed for indoor use Prevailing require strobes to be used where ambient noise conditions specified levels where occupants use hearing protection in areas of public accommodation Consult with your Authority Jurisdiction for details Genesis strobes exceed UL synchronization requirements 10 milliseconds over a two hour period when used with a source Synchronization for multiple strobe lights a single field of view is required See the Specifications table for synchronization sources Application suggested sound pressure level for each signaling zone used alert or alarm signals is a minimum of 15 dB above the aver ambient sound level or 5 dB above the maximum sound level a duration of at least 60 seconds whichever is greater This measured 5 feet 1.5 m above the floor the distance from the signal to the ear will theoretically a 6 dB reduction in the received sound pressure level The effect depends on the acoustic properties of materials in the Doubling the power output of a device e g a speaker from W to 2 W will increase the sound pressure level by 3 dBA A 3 difference represents a barely noticeable change in volume audible visual signals must be installed in accor with guidelines established for strobes Fidelity Models G4HF Series High Fidelity appliances provide highly intel voice audio output They are also effective in areas subject high levels of ambient noise These appliances are approved for in sleeping areas under conditions described below Room Applications GCHF Series High Fidelity appliances are ideal for hotels and other residential occupancies where audible must meet the 520 Hz signaling characteristics required by 72 sleeping areas always ensure that the wattage tap of the is set sufficiently high so that the sound pressure reaches least 75 dBA fast at the pillow appliances are part of an end to end audio system ap for use in sleeping areas when used in conjunction with audio hardware and a factory supplied 520 Hz tone the System Compatibility List for other 520 Hz signaling Speakers driven by third party audio systems not UL approved for use in sleeping rooms Notification Applications Mass Notification appliances bring same high performance life safety and unobtrusive design to mass applications Models are available with optional ALERT labels which make them ideal for applications that require between life safety and mass notification alerts Notes Canada in part on 1995 Canada National Building Code signal sound pressure level shall not exceed 110 dBA in any occupied area The sound pressure level from an audible in a floor area used for occupancies other than residential shall not be less than 10 dBA above ambient levels never less than 65 dBA In sleeping rooms the sound pres level from an audible signal shall not be less than 75 dBA any intervening doors between the device and the sleeping are closed and Mounting models are intended for ceiling or wall applica only Speaker strobes mounted to a flush 4 square box 21 8 54 mm ceiling speaker simply unlatch and down to open This access to mounting and the selectable candela tap switches The shallow of Genesis devices leaves room behind the signal for wiring Once installed with the in place no mounting screws visible 4 of Box of ceiling tile speaker strobe Note installed these devices are not on the electrical box Make boxes are mounted to compensate for this difference Use the mount template provided with installation sheet 3100614 switch Configuration ceiling speaker may be set for or 2 watt operation De on the model Gen ceiling speaker strobes multi candela output ordering information settings are changed by simply opening the device and the switches to the desired settings The speaker strobe not have to be removed to change the output settings The remain visible through small windows on the front of the after the cover is closed dia mm mm 2 of 6 D A T A S H E E T K85001 0641 to be used for installation purposes Issue 1 Sound Output dBA From Speaker output effective cd of rated output 60 90 100 110 120 1.5m 3.05m at 2 watts setting in anechoic chamber of UL versus and vertical outputs reflect the same pattern 1480 Strobe Output and Current Draw switch setting Hz High Fidelity models dBA o