Kidde Edwards Data Sheet K85005-0127 - Auxiliary Power Supply

File Preview
File Preview
Click below to download for free

Text Preview

Auxiliary Supplies APS10A 6020 Auxiliary Power Supply APS is a UL 864 9th Edition listed supply It is a 24 Vdc filtered regulated and supervised that can easily be configured to provide additional notification circuits NACs or auxiliary power for Mass Notification Communication MNEC as well as life safety security access control applications APS contains the circuitry to monitor and charge internal external batteries Its steel enclosure has room for up to two ampere hour batteries For access control only applications APS can support batteries totaling up to 65 ampere hours in external enclosure The APS has four Class B convertible to Class A NACs These can be activated in one or two groups the APS unique dual input circuits The APS has a door AC power indicator LED APS also has room for and can power a number of different These can be Signature AA 30 or AA 50 dual channel amplifiers UIO modules and or GSA RELs APS is available in 6.5 or 10 ampere models Each output cir is has a capacity of three amperes total current draw cannot the unit rating Allows for reliable filtered and regulated power to be installed needed Cost effective system expansion Provides for Genesis and Enhanced Integrity notification ap synchronization Supports coded output operation Self restoring overcurrent protection Multiple signal rates Can be cascaded or controlled independently On board diagnostic LEDs identify wiring or internal faults Standard Kidde keyed lockable steel cabinet with removable field configuration and 230 Vac models available Accommodates 18 to 12 AWG wire sizes Optional tamper switch Dual battery charging rates APS meets current UL requirements and is listed as under the standards CCN 9th ed ition UOXX Fire Alarm Systems ANET UEHX7 AOTX AOTX7 ALVY UEHX7 APAW APAW7 Police Station Connected Burglar Alarm Units and Systems APOU APOU7 Proprietary Burglar Alarm System Units AMCX UOXXC AOTX7 No 205 Station Alarm Unit Units Fire Alarm Canada Burglar Alarm Units and Systems Canada Equipment Canada Alarm Units and Systems Burglar Alarm Units and Systems Control Systems 1 of 4 D A T A S H E E T K85005 0127 to be used for installation purposes Issue 1 Catalog u Power Supplies and AccessoriesTechnology that saves livesfirealarmresources com APS provides additional power and circuits for notification ap and other 24 Vdc loads It is listed for indoor dry locations can easily be installed where needed conditions are indicated on the on board diagnostic LEDs the APS input sense circuit and the trouble relay if While this provides indication to the host system APS can still be activated upon command A separate AC contact is available on the APS circuit board which can be for trouble or AC Fail There are seven on board LEDs one for each NAC fault one for battery fault one ground fault and one for AC power unique dual input activation circuits of the APS can be acti by any voltage from 6 to 45 VDC filtered regulated or 11 to Vdc full wave rectified unfiltered The first input circuit can be to activate 1 4 of the four possible outputs The second circuit can be configured to control circuits 3 and 4 When are configured for auxiliary operation these circuits can be to stay on or automatically deactivate 30 seconds after power is lost This feature makes these circuits ideal for door applications The APS also has a separate 200 mA 24 Vdc that can be used to power internal activation modules NACs can be configured for a 3 3 3 temporal or continuous California temporal rate outputs are also available on cer models This makes the APS ideal for applications requiring rates that are not available from the main system addition to the internally generated signal rates the APS can also configured to follow the coded signal rate of the main system This allows for the seamless expansion of existing NACs the top of the steel enclosure the APS has space and mount bosses for Up to two SIGA AA30 or SIGA AA50 dual channel audio am One GSA UIO6 or GSA UIO6R module motherboard Up to two GSA UIO2R module motherboards Up to two GSA REL releasing modules Up to two GSA MP2L mounting plates modules above devices are in addition to the three factory installed Signa module mounting brackets to the right of the APS circuit board Specification where needed Kidde APS Series Auxiliary Power Sup APS that are interconnected to and supervised by the main The APS shall function as a stand alone auxiliary power with its own fully supervised battery compliment The APS compliment shall be sized to match the requirements of the system The APS shall be capable of supervising and charging having the capacity of 24 ampere hours for Mass Notifica Communication MNEC life safety and security ap and the capacity of 65 ampere hours for access control APS shall be capable of installation for a seismic com Importance Factor of 1.5 The APS shall provide a of four independent fully supervised Class B circuits can be field configurable for notification appliance circuits or 24 Vdc power circuits APS NACs shall be convertible to minimum of two Class A NACs Each APS output circuit shall rated at 3 amperes at 24 VDC Each output circuit shall be with automatically restoring overcurrent protection The shall be operable from the main system NAC and or Kidde Series control modules APS NACs shall be configurable continuous 3 3 3 temporal or optionally California rate Fault on the APS shall not impede operation of main sys NAC The APS shall be provided with ground fault detection and a separate AC fail relay Layout Enclosure Houses the electronics and two standby Heat sink Distributes heat away from the circuit board Circuit board Provides connections for all circuits Tamper switch standoffs 3 TAMP mounting standoffs JP3 Ground fault enable or disable option AC LED AC power on Mounting brackets Option module mounting brackets JP1 and JP2 Class A or Class B NAC option DIP switches Two eight position DIP switches used Circuit LEDs NAC battery and ground fault trouble configuration Batteries Up to two 12 V 24 Ah batteries fit in the For larger batteries use an external battery BC 1 or BC 2 Jumper JP4 Battery charging jumper Option module GSA REL GSA UIO6 6R 2 GSA mounting area Remote LED wiring harness connection Remote LED Indicates AC power is on 2 of 4 D A T A S H E E T K85005 0127 to be used for installation purposes Issue 1 Wiring Class A wiring mA AUX 1 2 one NAC circuit to one NAC output either NAC1 or NAC3 the circuit at the NAC2 or NAC4 terminal screw respec a single NAC circuit to one NAC output Terminate the with a 15 k Ohm EOL resistor Class B wiring NAC NAC Appliance Circuit NAC UL Listed k Ohm of up to four NACs from signaling circuit next booster or NAC to existing panel Circuit power fail from signaling circuit is a control circuit are not permitted next booster or end of line mA AUX 1 2 Circuit power fail wiring notes A trouble on the APS is sensed on the existing control panel NAC circuit causing a NAC trouble on that panel This the need to separately monitor the trouble contact except for AC power failure see 3 below an alarm condition the APS allows NAC current to move downstream to devices connected to the existing control panel NAC circuit Refer to the connected control panel documentation for more detai

Related Files