Kidde Edwards k85001-0557 - Genesis Ceiling Strobes

File Preview
File Preview
Click below to download for free

File Data

Name kidde-edwards-k85001-0557-genesis-ceiling-strobes-8143062957.pdf
Type PDF
Size 880.65 KB
Downloads

Text Preview

Field Configurable Strobes Series or more patents pending life safety and mass notification emergency communica ECS MNS ceiling strobes are small compact and attractive emergency signaling devices Protruding no more than 1.6 mm from the ceiling Genesis strobes blend with any decor Features Field configurable no need to remove the device 15 30 75 95 cd and 95 115 150 177 cd clear strobe lens models available Switch settings remain visible even after the unit is installed to patented breakthrough technology Kidde Genesis do not require bulky specular reflectors and lenses an exclusive cavity design conditions light to produce highly controlled distribution pattern Significant development employing this new technology have given rise to a new in strobe performance FullLight technology strobe technology produces a smooth light distribution without the spikes and voids characteristic of specular This ensures the entire coverage area receives consis illumination from the strobe flash As a result Genesis strobes FullLight technology go well beyond the minimum UL required pattern significantly exceeding UL 1971 and ULC S526 distribution requirements on the model clear lens Genesis ceiling strobes fea 15 to 95 or 95 to 177 candela output see ordering informa which is selectable with a conveniently located switch The output setting remains clearly visible even after final instal yet it is locked in place to prevent unauthorized movement installation ECS MNS models available 13 26 65 82 and 82 100 130 155 1971 equivalent amber lens models available Unique low profile design 30 per cent slimmer profile than comparable signals Attractive appearance No visible mounting screws Available with white or red housings Easy to install Fits all standard 4 square electrical boxes with plenty of 18 to 12 AWG terminals ideal for long runs or existing wiring behind the signal for extra wire no extension ring or plate needed Unparalleled performance Exclusive FullLight strobe technology produces the industry most even light distribution Precision timing electronics meet tough synchronizing standards for strobes Low current draw minimizes system overhead ECS MNS appliances offer emergency signaling with or amber lenses and with optional ALERT housing labels are ideal for applications that require differentiation between safety and mass notification alerts Approved for public and private mode applications UL 1971 listed as signaling devices for the hearing impaired UL 1638 listed as protective visual signaling appliances UL ULC listed for ceiling or wall use 1 of 4 D A T A S H E E T K85001 0557 to be used for installation purposes Issue 1 Catalog u Strobes Horns Bells ChimesTechnology that saves livesfirealarmresources com strobes are UL 1971 or 1638 listed for indoor use Prevailing require strobes to be used where ambient noise conditions specified levels where occupants use hearing protection in areas of public accommodation Consult with your Authority Jurisdiction for details Genesis strobes exceed UL synchronization requirements 10 milliseconds over a two hour period when used with a source Synchronization for multiple strobe lights a single field of view is required Applications ECS MNS appliances bring the same high performance life features and unobtrusive design to mass notification applica Available as standard units with clear or amber lenses with ALERT markings thy are ideal for applications that require between life safety and ECS MNS signals Units are available special order with red blue or green lenses models are intended for indoor applications only Strobes to any flush North American 4 square electrical box 21 8 mm deep ceiling strobes simply unlatch and twist to open This access to mounting screws and the selectable candela The shallow depth of Genesis devices leaves ample room the signal for extra wiring Once installed with the cover in no mounting screws are visible dia mm mm mm output effective cd of UL rating versus angle of rated output 60 90 100 110 120 and vertical outputs reflect the same pattern Configuration on the model Genesis ceiling have multi candela output ordering information The output is changed by simply opening the and sliding the switch to the desired The strobe does not have to be to change the output setting setting remains visible through a small on the front of the device after the is closed switch wiring terminals accommodate 18 to 12 AWG 0.75 mm 2.5 mm wiring Strobes are interconnected with a single pair of as shown below These devices will not operate without electrical power As fires frequently power interruptions we suggest you discuss further safeguards with your fire protection specialist 2 of 4 D A T A S H E E T K85001 0557 to be used for installation purposes Issue 1 Draw output switch settings for UL 1971 listed models are selectable by numeric candela value appliances are selectable by A B C or D designations output setting standard models output setting high output models or or or or or or or or Vdc Vfwr Vdc Vdc Vdc Vdc Vfwr Vfwr Vfwr Vfwr values are shown in mA output setting standard models output setting high output models or or or or or or or or Connections Voltage environment listings approvals output rating operating voltage flash rate Sources UV stabilized color impregnated engineered plastic Exceeds 94V 0 UL flammability rating Red and white models grade polycarbonate clear mount to North American 4 inch square electrical box 2 1 8 54 mm inches deep No extension ring required for indoor wall or ceiling applications terminals 18 to 12 AWG 0.75 mm to 2.5 mm wire size 16 to 33 Vdc 16 to 33 Vfwr 32 120 F 0 49 C ambient temperature 0 93 relative humidity or exceeds year 2004 UL requirements for standards UL1638 and UL1971 and Canadian requirements for CAN ULC S526 02 and CAN ULC S524 01 All models comply with ADA Code of Federal Regulation Chapter Part 36 Final Rule CSFM MEA FM pending 1971 UL 1638 ULC S526 selectable 15 30 75 95 cd GC VM and 95 115 150 177 cd GC VMH series strobes non coded filtered 16 33 Vdc unfiltered 16 33 Vdc FWR series strobes one flash

Related Files