Kidde Edwards K85005-0126 -- FX Series Conventional Fire Alarm Systems1
File Preview
Click below to download for free
Click below to download for free
File Data
Name | kidde-edwards-k85005-0126-fx-series-conventional-fire-alarm-systems1-4763015289.pdf |
---|---|
Type | |
Size | 1.03 MB |
Downloads |
Text Preview
Conventional Fire Systems FX 10R FX 5RD FX 5R 6230 brand conventional fire alarm systems consist of 5 and zone fire alarm control panels FACP an optional integrated DACT dialer intelligent analog type detec features serial annunciator modules and serial remote relay All FACPs and components are Listed to the 9th edition the ANSI UL 864 standard and CSFM FDNY approved systems incorporate features designed to simplify installation and maintenance including front panel programming one walk testing and selectable IDC and NAC types In addition used with CleanMe compatible smoke detectors these con panels provide intelligent type features such as remote mainte alert and automatic drift compensation that significantly reduce chance of a false alarm and simplify maintenance calls systems are powerful enough to meet the demands of life safety installations while leaving plenty of room to grow the future They support Class A operation by combining pairs of IDCs or NACs to provide the necessary Class A circuits example the FX 10RD comes factory set to support 10 Class B and 4 NACs But it can be field configured to provide 5 Class IDCs no Class B IDC and 2 Class A NACs or any other com of circuits that fall within the circuit pairing parameters B IDCs A IDCs B NACs A NACs Power power to 10 to 5 to 4 to 2 amps amps to 5 to 2 to 2 amps amps Class A operation will reduce the number of available Class B IDCs and or NACs on the panel configuration See Specifications for details Features Available in 5 and 10 zone IDC models CleanMe feature provides remote annunciation of a dirty Automatic drift compensation with select detectors reduces false and extends dust life Listed to ANSI UL 864 9th Edition Models with fully integrated upload download DACT enables programming Zone or NAC pairs convertible to single Class A circuits Combination Waterflow and Supervisory IDCs NACs programmable by zone and individually selectable for appliances continuous temporal outputs or coded Front panel programmable simplifies installation and servicing Precision synchronization with compatible notification appli and optional audible silence over two wires On board relays for Alarm Supervisory and Trouble Optional serial bus relay modules are programmable for Com Zone or Matrix activation Optional serial bus remote annunciator family One person walk test audible or silent Optional City Tie and Reverse Polarity Modules Trim ring available for semi flush mounting 1 of 8 D A T A S H E E T K85005 0126 to be used for installation purposes Issue 1 Catalog u Small Building Fire Alarm SolutionsTechnology that saves livesfirealarmresources com conventional fire alarm systems provide smoke and fire de occupant notification and off premises signaling for small medium sized buildings IDC can be configured for either Class B or Class A opera and one of eight operating modes Alarm or without smoke detector verification including LED Display following system LEDs display the panel status Alarm panel is in the alarm state Trouble panel is in the trouble state Supervisory panel is in the supervisory state Power indicates the status of the AC power source Disable indicates when any IDC NAC relay or the DACT is Annunciator Trouble indicates trouble on the remote an Battery Trouble indicates battery or charging problems Ground Fault indicates a short between any panel circuit Walk Test indicates that one or more IDCs are in the walk bus ground mode Alarms Silenced indicates that the panel is in the alarm state one or more NACs silenced Waterflow indicates that one or more circuits have detected active waterflow switch Service Detector indicates the presence of a dirty detector CleanMe compatible ESL smoke detectors Remote Disconnect indicates off site communication has disabled IDC has a disable switch and three LEDs Alarm red indicates that the IDC is in the alarm state Trouble yellow indicates that the IDC is in the trouble state is disabled when flashing Supervisory Monitor yellow indicates that the IDC is in the state or the monitor state when flashing NAC also has a disable switch and a trouble disable LED indication with the DACT Dialer installed optional upload download dialer LCD display provides lines x 16 characters of text For programming the top line the programming step and the lower line displays the option All system events are displayed on the LCD with zone messages During normal operation the LCD will any off normal condition present in the panel of contact devices Waterflow Alarm Waterflow Alarm Supervisory Combination IDC Supervisory Latching non latching Monitor non alarm or supervisory Signal Silence Drill Cross zoning may also be configured for either Class B or Class A Additionally NACs can be individually configured for of six outputs These are Genesis Genesis A V silenceable Temporal Coded and City Tie The Genesis selec allows independent horn control over two wires and provides synchronization of notification appliances all without the for a signal master accessory configured for compatible notification appliances the Alarm function will silence connected audible appliances but will remain active until the panel is reset When Genesis is selected both the horns and strobes on compatible notifi appliances will be synchronized across all NACs Zones may be selected for either latching or non latching Always check with your AHJ regarding approval silencing audible while leaving strobes flashing with intelligent features a conventional price combined CleanMe smoke detectors systems provide intel features at a conventional If a CleanMe detector out of the UL sensitivity Kidde patented remote reporting sends an to the control panel This reduces the chance of a alarm and simplifies service In addition CleanMe smoke detectors have built in drift compensation that the time between cleanings If cleaning is ever necessary is literally a snap with the Kidde exclusive replaceable optical For a complete list of CleanMe compatible smoke visit http Kidde fire com 2 of 8 D A T A S H E E T K85005 0126 to be used for installation purposes Issue 1 AC block fuse transformer wiring block 120 Vac 15 A 60 Hz branch circuit 230 Vac 15 A 50 60 Hz branch circuit wrap connector communication fully integrated upload download dialer is available for reporting to a monitoring facility The DACT also supports uploading downloading of system configuration status and event history DACT is programmable for either single or dual line opera It also supports split and dual reporting for two digital alarm DACT brings additional features to the panel including a alphanumeric LCD display local or remote PC pro and an event history log Annunciators and Relays serial bus standard on Kidde conventional control panels is installation time saver This circuit allows the connection of System Indicators FSRSI Remote Zone Indicators FSRZI FSRZI SA and Remote Relay Modules FSRRM24 over a four data and power circuit Annunciator and relay modules can be up to 1,000 feet from the panel on 18 gauge wire are also available for City Tie CTM and Reverse Polarity connections