ESL 1500PIB

File Preview
File Preview
Click below to download for free

File Data

Name esl-1500pib-7952168034.pdf
Type PDF
Size 797.34 KB
Downloads

Text Preview

E S L R O D U C T N F O R M A T O N B U L L E T N SERIES Alarm Panels numbers 1503 1505 1500 Series Fire Alarm Control Panels one 1501 three 1503 or five 1505 initiating circuits and two alarm circuits All initiating and indicating circuits conventional two or four wire Class or wiring loops All zone inputs and outputs power limited basic control panel Model 1501 includes the enclosure with removable door and the Master Board BMB The BMB provides all required for a single zone system including integral power supply 24 V DC battery charger supervision circuitry AC brown out circuitry control switches operating and diagnostic one man walktest alarm verification and alarm and system trouble dry relay The Models 1503 and 1505 include one or dual Zone Expander Modules 1500 ZEM 1500 Series Fire Alarm Control Panels are to meet world installation and needs To meet specific project a variety of optional modules are The cabinet 14 high and wide includes for five initiating circuits two indicating numerous option modules and standby Power limited per NEC article Section C Modular design 1 3 5 zone Class A or B standard One man walktest Alarm verification Approved for sprinkler and waterflow Options Digital Alarm Communicator City Masterbox Communicator Remote Annunciators Zone Relay Modules Polarity Reversal Modules S L 1500 Series Fire Alarm Control Panels are for use in commercial industrial and applications The ESL 1500 Series is also for occupancies such as hotels motels and Pre configured in one three and five zone they provide unsurpassed features in their configuration To meet special application needs range of options are available including a Digital Communicator 1500 DAC2 1500 Series may be surface mounted or semi flush using the optional trim kit 1500 TK One suits all three models and provides adequate for all standard and optional modules and battery requirements 1500 Series Fire Alarm Control Panels should be in accordance with the ESL 1500 Series Manual included with the panels Clear and wiring details are provided in the 1500 Series Manual and on the label affixed to the door All system wiring should be in with the National Electrical Code NFPA state and local codes and the Authority Having AHJ ESL 1500 Series is Listed under Underwriters Inc UL Standards 864 Control Panels Fire Protective Signaling Systems The ESL 1500 is also approved by California State Fire Listing No 7165 447 121 and New York City of Buildings Material and Equipment MEA Calendar 472 86 SA Listings of of of Local L M WF SS Central Station CS Protected Premises Unit M WF Alarm DAC Auxilliary A M and WF A Automatic Detection smoke detectors heat detectors DAC Digital Alarm Communicator M Manual Fire Alarm Box Pull Stations NC Non coded SS Sprinkler Supervisory WF Water Flow Alarm Series Fire Alarm Control Panel with Remote 1500 RA 5A and Digital Alarm 1500 DAC2 Master Board Basic Master Board BMB provides all common functions for alarm supervisory and trouble including one man walktest alarm verifica one initiating and two indicating circuits for 24 V signals A 24 V DC power supply and battery provide 1.5 Amps of total system power LED are provided for AC power system trouble alarm zone trouble supervisory low no AC low battery ground fault and alarm indicating circuit 1 and 2 Control switches for system reset silence and zone disable walktest are also Test 1500 BMB provides a one man walktest feature feature allows one service person to perform a functional test of alarm initiating devices and control panel without the necessity for manual reset the control panel after each test Alarm signals momentarily providing the programmable signal option has not been selected then the control automatically resets Testing may be accom system wide or by individual zone A walktest is provided for each zone Verification 1500 BMB provides for selectable alarm The alarm verification feature provides a verification of all automatic smoke in accordance with UL Standards and is very in reducing nuisance alarms Any non contact type initiating device i e manual fire station etc will bypass the verification feature less than 15 seconds Should a second alarm occur Options Alarm Communicator Transmitter 1500 DAC2 1500 DAC2 is used for alarm supervisory and signaling via the public telephone network to Central Station or Remote Station per NFPA 72 module communicates with a digital alarm commu receiver DACR by means of eleven available formats 1500 DAC2 provides local annunciation with for remote annunciation and audible indica of telephone line trouble and communication The module has five alarm zones and one zone Energy Module 1500 LEM 1500 LEM is used for alarm notification via local city MASTERBOXES NFPA 72 The is equipped with a circuit disconnect switch and dedicated circuit trouble LED which indicates an switch position an open in the installation between the control panel and MASTERBOX or need to RESET the MASTERBOX Relay Module 1500 ZRM 1500 ZRM provides a Form contact 3 A 30 V 0.35 Power Factor for each zone Three models available providing a relay for each initiating circuit on the 1500 Series Panel selection Annunciators 1500 RA 5 1500 RA 5A 1500 RA 5 and 1500 RA 5A Remote Alarm feature red alarm and yellow trouble indicators translucent plastic legend strips for identification and a painted aluminum flush plate resists moisture and corrosion remote alarm annunciation is standard to models Both models feature 5 alarm zones while 1500 RA 5A also includes a trouble LED and plastic legend strips accommodate up to 20 typed or 20 eight point transfer letters per zone The LED indicators provide 100,000 hours of life are clearly visible through the legend strip a smoke detector within 2.5 minutes the will be cancelled and full panel alarm Smoke detectors and contact type devices be intermixed on a common circuit When used ESL smoke detectors the response time of this meets all California State Fire Marshal Supervision supervision includes detection of a ground on any installation wiring conductor except AC power and conductors connected to the trouble and alarm relay contacts In addition open in any alarm initiating circuit remote circuit or local energy master box trip will cause a trouble signal Alarm indicating are supervised for both opens and shorts Loss reduction brown out of AC power and loss of or voltage battery power are also supervised initiating circuits may be wired in Class or or configurations Each zone features a alarm output for remote annunciation and operate with either two or four wire ESL smoke Zone 2 may be programmed to monitor contact type sprinkler supervisory with distinct audible and visible indication A LED is provided on the 1500 indicating circuits 2 may be wired in Class Style or configurations and operate on a reversing principle with compatible Listed 24 V signals the BMB provides resettable auxiliary 24 V full wave rectified unfiltered auxiliary and trouble relays a remote drill test input and integral event sounder prioritized for distinct alarm and trouble signals Expander Module dual Zone Expander Module 1500 ZEM provides and trouble indicators for two initiating zones a disconnect walktest switch for each

Related Files