Faraday - 1462-1463 Master Time Programmer Data Sheets
File Preview
Click below to download for free
Click below to download for free
File Data
Name | faraday-1462-1463-master-time-programmer-data-sheets-6950837124.pdf |
---|---|
Type | |
Size | 634.52 KB |
Downloads |
Text Preview
1462 1463 MASTER TIME PROGRAMMER Microprocessor Based 1 Independent Clock Drive Circuit Controls Sync Impulse Digital Clocks 2 Bell Auxiliary Circuits Field Expandable to 6 Circuits Integral Power Off Time Accumulator 2,100 Total Event Capacity Bell Duration Programmable by Event 10 Different Alternate Schedules 32 Alternate Schedule Dates Holiday etc Automatic Daylight Saving Adjust Perpetual Leap Year Calendar Simple Menu Driven Programming 1 RS232 Port optional Built in Diagnostics 10 Year Time Keeping Battery Selectable Line Frequency 50 60 Hz Line Frequency Quartz Time Base U L Listed 1462 is capable of synchronizing impulse and synchronous secondary clocks as well providing automatic and manual operation of control circuits The unit uses the power frequency to insure accurate time keeping areas where the line frequency is unreliable quartz series also provides field enabled com automatic adjustment for Daylight Savings Program Time controller is powered from a 50 60Hz supply However in the event of a outage the 1462 series is capable of provid time keeping functions for a period of 10 years 1462 series will accommodate programming a total of 300 events per day Each event can programmed to occur on any or all days of the Up to 10 different alternate schedules shortened class schedule summer etc be programmed into the Program Time Con Thirty two alternate Schedule Days holiday dates can be scheduled to occur up to 100 in the future On these special days any one the 10 alternate schedules may be selected to on that day The alternate schedules may also enabled manually on any day When an alter schedule is enabled either manually or auto the schedule will revert back to the main at 12 00 Midnight In addition any one of 10 schedules can be selected to act as the main at any time is menu driven and is easily using the 16 point English Numeric while being prompted by the 32 character display Scan functions are available to and verify events in chronological order access may be limited to three different Schedule General and Technician Self routines are accessible only in the Tech level Bell Auxiliary circuits are standard Each has capability to control either signaling or utility Oversized relays are used to assure very life Each is rated at 8 amps inductive 30 resistive DRY N O Signal duration is field from 1 60 seconds Durations are on a per event basis Manual of Bell Auxiliary circuits is accom with a single keystroke One additional 4 circuit module cat 1464 may be added the total circuit capacity to 6 1462 series also features one independent correction circuit for control of most available clocks This circuit is field and includes the ability to manually the secondary clocks An optional RS232 is available for sending time information to equipment Duration cid 150 60 Seconds set PER EVENT Capacity Total Events 300 events per day Base between Line Frequency or Quartz Base Accuracy Frequency cid 150 determined by source Crystal cid 150 100 PPM Capacity Days RS232 D optional Charter LCD w LED Backlight 16 Button Functions Bell Ring Function Advance for Clocks Single Step All Call Information Surface Mount Unit 7 32 cid 148 H x 12 cid 148 W x 3 cid 190 cid 148 D H x 30.5cm W x 9.5cm D Rack Mount Unit H x 19 cid 148 W x 12 cid 148 D H x 48.26cm W x 30.46cm D Bell Auxiliary Circuit Adder This module an additional 4 8 Amp circuits to the master for bell and auxiliary circuits Contacts are N O Master to Master Synchronization Option In where it is necessary to have multiple Time Programmers synchronized together option must be added to each of the Master Programmers on the system An external power source is necessary for this option function RS 232 Port 1 RS 232 port on the Master Programmer provides transmission of date time data in ASCII format to other RS232 devices Power 50 60 Hz 2 amp Circuits Independent Circuit Ratings Amp Inductive 28VDC 120VAC Amp Resistive Circuits Circuits Standard cid 150 6 Maximum Ratings Amp Inductive 30 Amp Res 28VDC 120VAC N O Contacts Schedule Capacity Schedules Building Technologies Inc Fernwood Road cid 149 Florham Park NJ 07932 973 593 2600 cid 149 Fax 973 593 6670 www faradayfirealarms com The information contained in this document is intended only as a summary and subject to change without notice The devices described in this document have specific sheets which cover various technical limitation and liability information Copies these instruction sheets and the General Product Warning and Limitations Document also contains important information are provided with the product and are available the Manufacturer Information contained in these documents should be consulted specifying or using the product For further information or assistance concerning problems contact the Manufacturer 2.5M SBT IG 2004 Supersedes sheet dated 3 04