Faraday - FireWatch-200 Fire Alarm System Data Sheets

File Preview
File Preview
Click below to download for free

File Data

Name faraday-firewatch-200-fire-alarm-system-data-sheets-2391758640.pdf
Type PDF
Size 611.45 KB
Downloads

Text Preview

Effective January 1998 replaces April 1998 Fire Alarm System Control Unit 1 2 Zone Non Expandable Construction 2 Style B Class B Conventional Initiating Circuits 1 Style Y Class B Conventional Appliance Circuit Rated 3 4 Amp max 24 Vdc Nominal 120 Vac Primary Power Output Discrete Component Solid State Design Built In Surge Suppression Built In Brown Out Circuitry Low Current Drain of Panel Minimizes Battery Requirements Supervision of Battery Two Wire Smoke Detector Compatible Trouble Silence With Resound Ground Fault Circuit Disable Switch to Silence Alarm UL CSFM MEA Listed Made in U S A compact Model FireWatch 200 Fire Alarm Control is a two zone non expandable unit with built in suppression and brownout circuitry Ideal for sized buildings Model FireWatch 200 operates any compatible two wire smoke detector or other open channel alarm initiating device state panel circuitry features two Style B Class Initiating Device Circuits and one Style Y Class B Appliance Circuit rated 0.75 amps silence with resound disable switch and ground circuit come standard FireWatch 200 provides ground fault detection both and negative A single ground fault activates the buzzer and system trouble indicator FireWatch 200 operator functions are located behind the locked door There are slide switches for system reset silence and alarm silence charging capacity is up to 7 AH 24 Vdc The charging type is lead acid gel cel The control is protected from reverse battery connection by of a self restoring PCB mounted fuse If the is connected in reverse the fuse will open and a will be indicated The battery is supervised for no low battery If this condition occurs a trouble condi will be indicated on the system available for Model FireWatch 200 include Relay Module provides two system alarm with form C contacts rated for 3 amps 30 Vdc 120 Vac The board mounts in the back box above battery set Order number 13202 City Tie Module provides supervised output to a box transmitter and alarm Reverse polarity can be reconfigured to open on trouble if no alarm Order number 13203 Mounting Trim Ring 1 piece trim kit for 13 1 4 W x 12 3 4 H Order number 13209 1 1 Fire Alarm System Control Unit 1 Smoke Detector Power City Tie SCT Specifications temperature Normal 77 cid 176 F 20 25 cid 176 C 120 cid 176 F 0 49 cid 176 C up to 3 hours humidity 85 86 cid 176 F up to 24 hours Input Voltage Input Voltage 120 Vac 50 60 Hz 240 Vac 50 60 Hz primary input current 1.0 A at 120 Vac 0.5A at 240 Vac volt sealed lead acid battery set charge voltage 28 Vdc charge current 1.5 A input current 1.0 A capacity 7 A H Limited 24 Vdc nominal 1 V p p maximum Device Circuits Limited Style B Class B zones minimum voltage range 16 27 Vdc standby current 10 mA standby detector current mA 24 Vdc alarm current 53 mA ripple 1 Vac wire loop resistance 100 ohms Limited standby current 3.4 mA voltage 24 Vdc nominal alarm current 75 Amp ripple 1.5 Vac loop drop voltage 1.0 Vdc Polarity Limited 24 Vdc nominal 0.010 Amp maximum 1 Vac maximum Status Relays SRM Limited Contact Rating Amp 30 Vdc max resistive Amp 120 Vac max resistive wire loop resistance 6 ohms Construction Steel Red H 10 3 8 W 5 1 4 D and Trouble Power Supply Appliance Circuits Information No No Description Control Panel 2 IDCs Style B Class B 1 NAC Style Y Class B 13200 0 14 120 Base unit with surface cabinet 120 Vac 13200 0 14 240 Base unit with surface cabinet 240 Vac for FireWatch 200 Panel 13202 Alarm Relay Module 13203 Alarm City Tie Module 13209 Semi Flush Trim DC 100 Digital Communication Sub Assembly 14047 7.0 Amp Hr Battery Set 2 Fire Alarm System Control Unit 1 Wiring 1 2W Device 10808 Device Circuit B Style B Typical Limited Auxiliary Power Unsupervised Power must not exceed 24 Vdc 1 2W 1 2W Device Device 10807 10807 Appliance Class B Style B Power Limited Leads Set 7AH Supervised Limited Current 1A max Voltage 28V max Current 1.5A max 2 IDC 3 Fire Alarm System Control Unit 1 LLC South Maumee Street Michigan 49286 517 423 2111 517 423 2320 www faradayllc com The information contained in this document is intended only as a summary and is to change without notice The devices described in this document have specific sheets which cover various technical limitation and liability information Copies of instruction sheets and the General Product Warning and Limitations Document which contains important information are provided with the product and are available from the Information contained in these documents should be consulted before specifying using the product For further information or assistance concerning particular problems the Manufacturer 4

Related Files