Faraday - FireWatch II+2 Fire Alarm Data Sheets

File Preview
File Preview
Click below to download for free

File Data

Name faraday-firewatch-ii-2-fire-alarm-data-sheets-1587604329.pdf
Type PDF
Size 604.47 KB
Downloads

Text Preview

Effective April 3 2000 replaces August 1995 FireWatch II 2 Fire Alarm System Control 4 Zone Non Expandable Construction 4 Style B Class B Initiating Device Circuits 1 Style Y Class B Notification Appliance Circuit 2 1 2 Amps max 24 Vdc Nominal 120 Vac Primary Power Input Discrete Component Solid State Design Built In Surge Suppression Low Current Drain of Panel Minimizes Battery Requirements Supervision of Battery 2 or 4 Wire Smoke Detector Compatible Trouble Silence With Resound UL Listed Made in U S A Model FireWatch II 2 will provide manual waterflow alarm and supervisory service in convenient control unit FireWatch II 2 provides four Style B Class B device circuits with one Style Y Class B appliance circuit also features solid state component design and circuitry capable of operating up to 2.5 amps standard features include built in surge trouble silence with resound automatic circuit disconnect on the signal circuit and trouble ring back include Limited City Tie Module 15209 provides an transmitter and a form C system contact Annunciator Drive Module 15212 provides a annunciator output per zone capable of 21 28 Vdc LED indicators a form C trouble contact and a form C general contact Model FireWatch II 2 System Relay Module 15217 provides a form trouble contact and a form C general alarm The module also contains a disconnect and a trouble off normal switch LED March Time Temporal Audio Visual Module provides programming capabilities for control unit signal circuit Selectable City Tie Module 15215 provides a transmitter an alarm trouble or a local energy city box trip circuit a C system trouble contact and a form C alarm contact Digital Communicator Interface Module 15206 connection to DC 100 or DC 101 digital Supervisory Switch Module 15207 provides an required separate audible tamper switch off buzzer with integral buzzer silence switch yellow buzzer silenced LED indicator Includes buzzer re ring System Diagnostic LED Readout Card 15208 for meter system troubleshooting 1 FireWatch II 2 Fire Alarm System Control temperature Normal 120 cid 176 F 0 49 cid 176 C humidity 86 cid 176 F Input Voltage Input Voltage 120 Vac 50 60 Hz primary input current Amp at 120 Vac Smoke Detector Power Appliance Circuits Limited Range 24 Vdc nominal Output Up to 0.3Amp limited by capacity Ripple 1.2 V Device Circuits Limited Style B Class B voltage range 16 28 Vdc standby current 7.6 mA standby detector current 3 mA alarm current 36 mA ripple 1.2 Vac wire loop resistance 100 ohms Limited Y Class B standby current 0.47 mA voltage 24 Vdc nominal alarm current 2.5 Amp 24 Vdc ripple 16 Vac loop drop voltage 1.0 Vdc Construction Steel Red H 14 5 8 W 5 D Circuit Limited 1 2W 5 Smoke Detector Power max only compatible 4 wire detectors specified in manual unsupervised 60Hz max Ground only smoke and specified owner manual Ratings max 24Vdc 1 2W 5 Circuit No 1 Circuit No 2 Circuit No 3 Battery Set Circuit No 4 Information No No II 2 15240A Base Unit with Surface Cabinet 15207 Supervisory Switch Buzzer Module 15208 System Diagnostic Card 15209 Limited City Tie Module 15212 Annunciator Drive Module 15213A March Time Temporal Audio Visual Module 15215 Selectable City Tie Module 15216 14 Semi Flush Collar 15217 System Relay Module 15219 Zone Relay Module 15206 Digital Communicator Interface Module 2000 Faraday LLC all rights reserved LLC South Maumee Street Michigan 49286 517 423 2111 517 423 2320 www faradayllc com The information contained in this document is intended only as a summary and subject to change without notice The devices described in this document have specific sheets which cover various technical limitation and liability information Copies these instruction sheets and the General Product Warning and Limitations Document also contains important information are provided with the product and are available the Manufacturer Information contained in these documents should be consulted specifying or using the product For further information or assistance concerning problems contact the Manufacturer 2

Related Files