Faraday - MPC-1000 Plus Fire Alarm Control Panel Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

Effective December 1 2001 Plus Intelligent Fire Alarm Control Panel One analog addressable SLC Faraday devices 60 or System Sensor 198 pts MPC Net networking compatible Supports Faraday or System Sensor SLC protocol Four NACs style Z Class A and style Y B Three 3 amp power supply 80 character backlit LCD with custom labeling LEDs for panel status indication Connection for 16 remote 80 character display LCD annunciators backlit on activation Optional internal DACT Fully field programmable via PC removable or automatic programming 500 event history log in nonvolatile memory Dynamic quick test functions Day Night sensitivity mode NFPA 72 sensitivity testing Manual alarm silence with 0 1 3 or 6 minute inhibit Auto silence selectable for each NAC 10 20 or 30 or none Test by device or the entire panel Silent or audible Quick Test 59 Software zones 255 notification and 255 relay circuits Two password levels tech maintenance UL listed standard 864 CSFM and MEA pending Made in USA ISO 9001 quality crafted MPC 1000 Plus is an advanced modular fire panel It features analog addressable detection and memory capability It base con includes one analog addressable loop with conventional notification appliance output circuits Plus controls and indicators are mounted behind locked cabinet door and an 80 character LCD provides specific indications for addressable while LEDs indicate general panel status Configuration main termination board mounts in the rear of the The main power supply is physically contiguous the main termination board The MPC 1000 Plus termination board provides the interface for analog system connections the analog loop PCB four signaling circuits remote signaling and indicating interfaces and the electronics of main system power supply front main logic PCB mounts in the back box it to carry the controls and displays which are from the front locked panel door Displays any number of zones are handled through this normal operation is controlled from the front of the via push button switches Displays are provided an 80 character alphanumeric backlit LCD display by discrete LED indicators for major panel 1 continued Plus Intelligent Fire Alarm Control Panel p POWER ON STATUS DISPLAY 01 01 02 Plus Normal 80 character display is used display event including and troubles of or device and of The display controlled by a of four push switches the processor back light is in the to assure in low light but to conserve power it is only during a reported event or operation of a control switch 1000 Plus SILENCE SILENCED UNIT BEFORE SERVICING SILENCE CONTROL RESET ALARM Control Unit Configuration Addressable Device Circuit addressable main termination board has loop interface circuitry supporting addressable device circuit Supports Faraday System Sensor SLC protocol Notification Appliance Circuits base panel has four independent NACs Each can be selected to give continuous output of eight sounding patterns or zone coding are style Z or Y capable without additional Dry Contacts Three form C dry relay contacts provided These contacts are dedicated to trouble and supervisory indications Remote Annunciation The MPC 1000 Plus will drive up to 16 annunciators and 8 remote on an RS 485 communication line Power Supply A 3.0A 24V nominal power provides all operating power to the panel for standby and alarm conditions 2.5 Amps are for the NAC circuit Devices Remote LCD Annunciator RDC 1 The remote annunciator consists of a backlit 80 character display 4 menu buttons 4 dedicated for operator interaction 6 LED indicators a security key switch Serial Annunciator SAU 1 Consists of remote and annunciator driver board capable of 16 supervised outputs for LEDs or lamps Expansion to drive 512 LEDs lamps is via additional processor boards and drive boards Serial Annunciator Extender SAE 16 Each processor board receives commands from control unit and is capable of controlling three boards and four annunciator boards of 8 remote processor boards in one Auxiliary power supplies will be required to units beyond the control unit capability Serial Relay Unit SRU 1 Consists of remote and relay board which provides 8 relays form C dry contacts rated at 1 amp to 192 relays is via additional remote boards and relay boards SRE 8 Control Unit Configuration DACT Expansion Module DC1K The DC1K a dual line digital alarm communications It parameters are set via the control programming sequence DC1K is compatible with the following formats DCS 8 SIA DCS 20 Ademco Contact ID 1400 Hz 3 1 2300 Hz 4 2 1400 Hz and 2300 Hz City Tie Module CT 1K This module local energy and reverse polarity and is easily connected RS 232 Module IM232A Used for connection to printer or NIB for MPC Net Network connectivity MPC Networking The MPC 1000 Plus is MPC networking compatible 2 Plus Intelligent Fire Alarm Control Panel Main Termination Board All wiring must be accordance with local and National Electric Use only FPL FPLR FPLP as described in 760 of N E C wiring and installation information owner manual 447192 Device Circuit 4 6 or 7 Operation jumper P1 for proper style nominal Resistance 20 ohms line Power Limited Owner Manual for Compatible Devices 6 7 4 60Hz max Supervised Limited Set to 38AH O C O C C O Contacts in normal condition Resistive Power Limited Unsupervised 24V 24V 24V Power 0.5A max 24VDC nominal Limited A B C D shown in activated condition Y Class B Power Limited Z Class A Power Limited Typical above Typical above Ratings Voltage 24VDC nominal Alarm Current 1.5A Ripple 16VAC Wire Voltage Drop 1.0VDC Standby Current 1.0mA The maximum current all NACs is 2.5A System Relays relays rated 1 amp 28 Vdc resistive per NAC circuit 1.5A ea 2.5 max Circuits cabinet will accommodate a 7 AH battery set Larger will require separate enclosure All Non Power Limited Wiring from Power Limited Wiring Interface Circuit nominal 0.4A max Resistance 25 ohms line 4000ft max Type Twisted pair for Data Power Limited X X Specifications temperature F 0 49 cid 176 C Humidity 86 cid 176 F Supply input voltage Vac 50 60 Hz 240 Vac 50 60 Hz primary input current amp 120 Vac and Trouble Power Supply volt lead acid battery with 7 AH 38 AH capacity Power Outputs 0.5 amp resettable non resettable power outputs 3 Plus Intelligent Fire Alarm Control Panel STATUS DISPLAY Plus Normal p 01 01 02 POWER ON

Related Files