Faraday MPC-DACT BOARD

File Preview
File Preview
Click below to download for free

File Data

Name faraday-mpc-dact-board-1734502968.pdf
Type PDF
Size 635.65 KB
Downloads

Text Preview

INSTALLATION INSTRUCTIONS AND WIRING FOR NO MPC DACT DACT BOARD MPC DACT Board is an optional module for the MPC 6000 and MPC 7000 Fire Alarm System Units and the RND 2 Remote Network Display The MPC DACT Digital Alarm Communicator Board provides telephone line connections for communication with a DACR Digital Alarm Receiver The DACT Board is mounted on the Main Board The MPC DACT Board are set through the control unit programming sequence SUPPLIED Board 1 Nut 6 32 Sheet 1 is to be done by qualified personnel have thoroughly read and understood this sheet 2 Disconnect BATTERY and AC prior to working on 3 Mount DACT Board as shown using four spacers 375 F943165 to the Main Board Check see are mated properly header and 4 Attach ground wire as shown using the nearest board mounting screw as shown 5 Attach conduit and run wires as required 6 Connect wires to the fire alarm system control unit required 7 Apply power to system 8 Program for proper operation of functions Tech Level Outputs Option Mods DACT CFG DACT line and general configurations Tech Level Outputs Option Mods DACT ACCTS DACT account configurations Maint Level Disable Enable Outputs DACT See Programmer Manual P N 315 for more details on programming 9 Check for proper operation of functions Building Technologies Inc Fernwood Road Park New Jersey 07932 315 699464FA 5 1 OF 4 WIRING Line Connection Ratings Limited 24VDC nominal Equivalence 0.4B Line 1 from TELCO Output to telephone The DACT may seize line to report events Line 2 from TELCO Output to telephone The DACT may seize line to report events The RJ31X provides a convenient connection allowing the to be installed and removed without requiring re wiring can be installed by the telephone installer FORMAT DESCRIPTION DCS 8 1400HZ 2300HZ 1400HZ 2300HZ Industry Association Digital Communications Standard Format may send up to eight events a call 1997 Level Ia compatibility with support for O old blocks and 300 Baud FAST operation an account number up to 6 digits a 2 character code and 3 digit identifier up to four times with FSK encoding SIA DCS 8 except format may send up to twenty events a call DCS 20 Contact ID Sends a 4 digit account number a 3 digit code and 3 digit identifier up to four rounds of dual tone multiple with 1400 and 2300 Hz handshake frequency a 3 digit account number and a 1 digit code up to four rounds at 20 pps with 1400 Hz handshake a 3 digit account number and a 1 digit code up to four rounds at 20 pps with 2300 Hz handshake a 4 digit account number and a 2 digit code up to four rounds at 20 pps with 1400 Hz handshake a 4 digit account number and a 2 digit code up to four rounds at 20 pps with 2300 Hz handshake RECEIVERS FORMATS Inc Knight Security Knight Security Knight Security II DCS DCS 1 8 1 20 DCS SIA DCS DCS SIA DCS ID ID ID ID ID 3 1 3 1 3 1 3 1 3 1 3 1 4 2 4 2 4 2 4 2 4 2 4 2 3 1 3 1 4 2 4 2 3 1 3 1 4 2 4 2 315 699464FA 5 2 OF 4 Hz or Hz or Type Point Alarm Point Alarm Restore Through Reset Point Alarm Point Active Point Restore Trouble Trouble Restore Up Reset Point Trouble Point Trouble Restore Trouble Restore All Clear Point Device Bypass Disable Bypass Disable Point Device Unbypass ReEnable Unbypass ReEnable Battery Trouble Battery Trouble Restore Circuit nn Trouble Circuit nn Trouble Restore Circuit Ground Fault Circuit Ground Fault Restore Ground Fault Trouble Ground Fault Trouble Restore Line 1 Trouble Line 1 Trouble Restore Line 2 Trouble Line 2 Trouble Restore Data Lost Test Drill begin Test Drill end Test Begin Test Stop Trouble qrs Trouble qrs Restore Test System Normal Test System Normal EVENT CODES DCS or 20 tuvw tuvw tuvw tuvw tuvw 0 0 0 tuvw tuvw 9 tuvw 298 tuvw 298 298 298 2nn 2nn 299 299 299 299 1 1 2 2 30 0 0 298 298 qrs qrs 30 30 ID 110 xyz 110 xyz 113 xyz 203 xyz 203 xyz 301 000 301 000 305 000 373 xyz 373 xyz 373 009 571 xyz 571 298 571 xyz 571 298 302 298 302 298 373 4nn 373 4nn 373 299 373 299 373 299 373 299 351 001 351 001 352 002 352 002 354 030 604 000 604 000 373 298 373 298 373 qrs 373 qrs 1 602 030 601 030 denotes input device address 1001 1252 where t represents loop number 1 xyz denotes input group address 001 240 that during the daily automatic test this code is always sent paired with the RP 30 Auto Test code denotes NAC circuit number 1 12 CODE IDENTIFIER DESCRIPTIONS CODE IDENTIFIER DESCRIPTIONS DCS CONTACT ID Digit Code Address 1 4 001 252 Group 001 240 Digit Code Trouble 315 699464FA 5 3 OF 4 ADEMCO TROUBLE CODES Type Trouble General Trouble Account 1 Account 2 Trouble Requirements Part 68 USA 34988 AL E equipment complies with Part 68 of the Federal Communication Commission FCC Rules and On the bottom is a label that contains among other information the FCC Registration and Ringer Equivalence Number REN for this equipment If requested this information must be to the telephone company Registration Number telephone jack Equivalence Number REN REN is useful to determine the quantity of devices that may connect to the telephone line Excessive on the telephone line may result in the devices not ringing in response to an incoming call In most not all areas the sum of the RENs should not exceed five 5.0 To be certain of the number of that may be connected to the line as determined by the total RENs contact the telephone to determine the maximum REN for the calling area the Model MPC DACT equipment causes harm to the telephone network the telephone company will you in advance that temporary discontinuance of service may be required If advance notice is not the telephone company will notify you of the discontinuance as soon as possible Also you will advised of your right to file a complaint with the FCC if you believe it is necessary teleph

Related Files