Farenhyt Addressable Device Guide

File Preview
File Preview
Click below to download for free

File Data

Name farenhyt-addressable-device-guide-5124609837.pdf
Type PDF
Size 1.16 MB
Downloads

Text Preview

Addressable Device Guide Series Devices IFP Series of re products offer exible easy to use and main re alarm control panels accessories and other critical tools to your re system You also have a choice between either the System Sensor IDP devices or Hochiki devices on the expanding your choices of our accessories are compatible with all of the addressable IFP re alarm control panels and the VIP voice integration panels Sensor IDP Devices required the FACP to maximize detection Addressable Photoelectric Smoke IDP Photo T Photoelectric Smoke with Thermal 135 Reliable communications for trouble free operation Dual electronic thermistor design on the IDP Photo T Dual LED indicators for 360 visibility Detector transmits signal to indicate maintenance Addressable Multicriteria Smoke Detector with Thermal 135 Incorporates both thermal and photoelectric On board microprocessor with advanced software rejects nuisance alarms Dual stage drift compensation reduces maintenance frequency Addressable Ionization Smoke Detector Single source dual chamber design to respond quickly to a broad range of res Sensitivity is continuously monitored and reported Fixed Temperature Thermal Detector 135 IDP Heat HT Fixed High Temperature Thermal 190 IDP Heat ROR Rate of Rise Detector with 135 Fixed Temperature IDP Heat is xed temperature at 135 57C IDP Heat HT is a xed high temperature detector at 190 88 IDP Heat ROR is a xed temp and rate of rise thermal detector that produces 135 thermal protection Detector transmits signal to indicate maintenance 6 Isolator Base Prevents an entire communication loop from being disabled from short circuit Restores entire loop when short circuit is corrected Isolates up to 25 IDP devices between SSB224BIs 6 Relay Base Built in Form C relay Controls wide variety of normally open and normally closed applications Support for Class A and Class B wiring 6 Temporal Sounder Base Built in sounder for three pulse temporal pattern evacuation signal Requires an external 24VDC power supply Support for Class A and Class B wiring 6 and SSB501 4 Mounting Base Plug in detector bases for IDP detectors Screw terminals for power and remote annunciator connection With tamper proof option required per minute to 4000 feet per minute Addressable Re ected Beam Smoke IDP Beam T Re ected Beam Smoke with added Test Feature Uniquely suited for protecting open areas with high ceilings IDP Beam T includes an integrated sensitivity test feature Listed for 22 to 131 30 to 55 16 to 328 foot protection range Addressable Single Action Pull Station Addressable Dual Action Pull Station Installer can open station without causing an alarm Dual color LED is visible through handle of station blinks green to indicated normal operation and steady red in alarm Key operated test and reset lock Duct Detector Housing Uses IDP Photo R Add IDP Relay for relay function Low ow technology enabling duct smoke detection a broad range of air ow environments Can detect smoke at air speed velocities from 100 Continuously monitored through the panel SLC Supports Class B or Class A wiring Fault Isolator Module Isolates short circuits on an SLC Protects the modules on the SLC so other devices continue to operate Mini Input Monitor Module Interfaces with contact devices such as water ow switches and pull stations Supports Class B supervised wiring to the load device Single contact monitor Input Monitor Module Acts as an interface to contact devices such as water ow switches and pull stations Supports Class A supervised or Class B supervised wiring Dual Input Monitor Module Addressable monitor module with two initiating circuits Interfaces to contact devices such as water ow and pull stations Supports Class B supervised wiring to the load device Ten Input Monitor Module Interfaces with contact devices such as water ow and pull stations Multiple input design allows for easy and ef cient installation Supports 10 Class B supervised contact inputs or ve Class A supervised contact inputs Addressable Relay Module Allows FACP to switch discrete contacts by code Contains 2 isolated sets of Form C contacts operating as a DPDT switch Used for either normally open or normally closed applications Six Relay Module Provides 6 Form C relays Allows FACP to switch discrete contacts by code command Up to 3 circuits can be disabled on board Addressable Zone Interface Module Two wire interface module Allows FACP to interface and monitor two wire conventional smoke detectors Supervises the zone of detectors and external power supply the load device Hochiki Protocol Devices Six Zone Interface Module Addressable zone interface module Provides 6 zone inputs to monitor 2 wire conventional smoke detectors Inputs share a common SLC input Initiating device circuits share a common external power supply Supervised Control Module Addressable noti cation module Adds noti cation circuits to an FACP SLC Provides supervised monitoring of wiring that require external power supply Class B or Class A supervision Six Circuit Supervised Control Module Addressable noti cation module Provides 6 integrated modules to add noti cation circuits to an FACP SLC Provides supervised monitoring of wiring that requires external power supply Class B or Class A supervision Addressable Input Module For use with Pull Stations water ow switches and other applications requiring dry contact alarm initiation devices Supervised single input contact monitors Operates on Class A or Class B SLC Mini Input Module For use with Pull Stations water ow switches and other applications requiring dry contact alarm initation devices Supervised single input contact monitors Addressable Noti cation Module Adds noti cation circuits to the SLC Up to 127 modules per loop Requires external power supply Class A or Class B noti cation circuits Addressable Relay Module Adds 2 Form C contacts Contacts rated at 2A 30 VDC or 6A 120VAC Up to 127 relays can be used on each SLC Loop Isolation Module Isolates a short circuit wiring fault on an SLC Can be used on Class A and Class B wiring Smoke Detector Module Assigns an address to a loop of conventional detection devices Devices can be dry contacts or 2 wire smoke detectors Can be con gured as Class A or Class B SLC Annunciator Driver Module Capable of driving 80 LEDs per SD500 LED Up to 40 SD500 LEDs can be used per SLC Single or Dual Action Pull Station Rugged Metal construction Terminals accept up to 14 gauge wire For indoor use Addressable Duct Detector Detects smoke and products of combustion in air moving Two wire connection to SLC Includes SD505 APS photo electric detector an HVAC system Fire Systems HFS Protocol Devices Addressable Fixed Temperature Thermal Detector Addressable Photoelectric Smoke Detector Addressable Photoelectric Detector with Thermal Addressable Relay Module Addressable Pull Station Duct Smoke Detector Miniature Monitor Module Addressable Duct Detector with Built In SD505 DTS K Addressable Duct Detector Switch Analog Addressable duct detector with built in relay module SD505 DTS K provides remote annunciation and testing capabilities for the SD505 DUCTR Two wire connection to SLC Addressable Heat Detector Programmable Temperature range from 135 to 150 Low pro le Addressable Ionizati

Related Files