Farenhyt Analog Addressable Devices with Intelligent Device (IDP) Protocol

File Preview
File Preview
Click below to download for free

Text Preview

Addressable Devices with Intelligent Protocol IDP Device Protocol IDP devices are intelligent devices for use with the following Farenhyt fire alarm control panels FACPs IFP 2000 ECS IFP 100 ECS and IFP 50 IDP detectors and accessories communicate to the FACP over the line circuit loop SLC loop using a two wire Shielded or twisted wire is not required Up to 99 IDP detectors and 99 IDP modules can with the IFP 50 IFP 100 ECS and IFP FACP on a single loop The IFP 2000 ECS can up to 159 IDP detectors and 159 IDP modules on a SLC loop Any combination of addressable IDP devices IDP modules can be used on a single SLC loop assortment of IDP detectors modules and accessories are compatible with Farenhyt addressable FACPs are below For detailed information on IDP devices see device specification sheet plug in photoelectric smoke IDP Photo offers a optical sensing chamber is engineered to sense produced by a wide range combustion sources Base Not Included plug in photoelectric smoke detector with thermal offers a unique optical sensing chamber that is to sense smoke produced by a wide range of sources Dual electronic thermistors add 135 thermal technology to maximize detection plug in ionization smoke detector IDP Ion incorporates a single source dual chamber design to respond quickly a broad range of fires fixed temperature and rate of rise thermal detector that uses thermistor sensing circuit to produce 135 57 thermal Rate of rise detection occurs at 15 per minute per minute beam smoke detector that is suited for protecting open with high ceilings where methods of smoke detection difficult to install and maintain beam smoke detector that an integrated sensitivity feature The IDP Beam T is suited for protecting open areas with high ceilings other methods of smoke detection are difficult to install maintain DNR Intelligent non relay duct smoke detector and DNRW watertight non photoelectric duct smoke housing head not included for use in air handling systems have air velocities of 100 to 4000 ft minute test capable head replacement for DNR DNRW that a date code of 0013 or newer both thermal and photoelectric technologies that to maximize detection The IDP Acclimate has an on microprocessor with advanced software that focuses on nuisance alarms IDP FIRE CO is a plug in addressable device that both fire and carbon CO detection The IDP should be used in with the B200S sounder base fixed temperature thermal that uses a thermistor circuit to produce 57 fixed thermal variable high temperature that provides high detection at 135 190 57 88 Base Not Included B200S Not included 350361 Rev G 2015 Honeywell International Inc monitor module that acts as an to contact devices such as switches and pull stations IDP Monitor supports Class B or Class A supervised compact and light weight monitor module that acts as an to contact devices such as waterflow switches and stations The IDP Minimon supports Class B supervised monitor module with two initiating circuits that acts as an to contact devices such as waterflow switches and stations Because the IDP Monitor 2 is capable of two separate Class B circuits it is ideal for tamper switch and flow switch monitoring 10 point monitor module that acts as an interface to contact such as waterflow switches and pull stations 4 wire smoke detectors can be monitored for and trouble conditions The IDP Monitor 10 supports ten B or five Class A supervised contact inputs relay module that allows an FACP to switch discrete contacts code command The relay contains two isolated sets of C contacts which operate as a DPDT switch relay module that has six Form C relays The IDP Relay 6 an FACP to switch discrete contacts by code command can be used by virtually any normally open or normally application IDP Relaymon 2 combines two relay outputs and two inputs into one module device The module is capable Class B supervised wiring to the monitored devices It also Form C relay contacts allowing the panel to switch the on command notification module that lets you add notification circuits they are needed on an FACP SLC loop The IDP provides supervised monitoring of wiring to load such as bells horns and strobes The IDP Control Class B and Class A wiring notification module that has six modules for maximum allowing you to add circuits wherever they are on an FACP SLC loop two wire interface module that allows an FACP to interface and monitor two wire conventional smoke detectors This you can retrofit an existing building and use existing devices The IDP Zone supports Style B and Style wiring two wire interface module that has six integrated modules allows an FACP to interface with and monitor two wire smoke detectors This means you can retrofit an building and use existing conventional devices The supports Class B and Class A wiring line isolator module that acts as an automatic switch that when the line voltage on the SLC loop below four volts Isolator modules are between groups of sensors or in a loop to protect the rest of the If a short occurs between any two then both isolators immediately to an open circuit state and isolate the between them IDP Pull SA is a single action pull station requiring only motion to activate the station The IDP Pull DA is a dual pull station requiring two motions to active the station 6 mounting base with built in remote annunciator B200SR is designed for new and existing dwelling unit It offers maximum flexibility in installation and operation to meet or exceed UL 268 and UL requirements sounder base in to the communication between attached sensor head and the fire alarm control panel to adopt the same address as the detector but as a device type on the loop The B200S has support for CO using the IDP FIRE CO 6 mounting base with a built in Form C relay contact Lets control a wide variety of normally open and normally applications The B224RB supports Class B and Class wiring 6 mounting base with a built in isolator for IDP series The B224BI prevents an entire communication loop being disabled when a short circuit occurs by isolating part of a loop that has a short from the rest of the loop the entire loop when the cause of the short circuit is Supports Class B and Class A wiring document is not intended to be used for installation purposes We try to keep our product information and accurate We cannot cover all specific applications or anticipate all requirements All are subject to change without notice For more information contact Silent Knight 12 Clintonville Northford CT 06472 1610 Phone 800 328 0103 Fax 203 484 7118 Technical Support Please call 800 446 6444 www farenhyt com

Related Files