Intelligent Sounder Bases B200S sounder base series is designed for new and commercial dwelling unit applications It offers flexibility in installation configuration and operation meet or exceed UL 268 and UL 464 requirements sounder base in to the communication between attached sensor head and the fire alarm control panel to adopt the same address as the detector but as a device type on the loop The FACP can then use that to command an individual sounder or a group of to activate In addition the FACP will enable tone patterns B200S series sounder bases recognize the System synchronization protocol This enables it to be used as component of the general evacuation signal along with System Sensor horns horn strobes and chimes connected to a FACP output programmed as sounder power B200S LF low frequency sounder base is designed to the NFPA 72 sleeping space requirement to produce a frequency of 520 Hz 10 with a square wave its equivalent Studies show that a lower frequency around 520 Hz is the most ideal to awaken sleeping even those with mild to severe hearing loss Addressability for maximum configuration flexibility Supports Continuous ANSI Temporal 3 ANSI Temporal 4 March Time tones Custom tone capability with some FACP models Ability to synchronize with other System Sensor notification UL 268 and UL 464 compliant Pre wire mounting plate fits various junction box sizes Uses a mechanical locking feature that prevents the of the attached sensor head No external relays and input modules needed to supervise Aux power 520 Hz 10 square wave tone B200S LF B200S series sounder bases can be mounted directly to 10.16 cm square 4 10.16 cm octagon 3 1 2 8.9 cm single gang or double gang junction boxes B200S series are compatible with the following IDP detectors programmed for System Sensor protocol version 13.0 or higher for IFP 100 IFP 1000 version 4.0 or higher for IFP 2000 Listings IDP Photo Photoelectric Smoke Detector IDP Photo T Photoelectric Smoke Detector Thermal IDP Ion Ionization Smoke Detector IDP Acclimate Multicriteria Photoelectric Detector IDP Heat Fixed Temperature Thermal IDP Heat ROR Rate of Rise Detector with IDP Heat HT Fixed High Temperature Detector IDP FIRE CO Multi Criteria CO and Smoke B200S B200S LF are compatible the following FACPs IFP 2000 RPS 2000 Intelligent Fire Panel IFP 2000ECS Emergency Communication with Fire Alarm Control Panel IFP 1000 Intelligent Fire Panel IFP 1000ECS Emergency Communication with Fire Alarm Control Panel IFP 100 Intelligent Fire Panel IFP 100ECS Emergency Communication with Fire Alarm Control Panel 351564 Rev B 2015 Honeywell International Inc B200S B200S LF Output than 85 dBA minimum in a UL reverberant room 10 feet 24 Volts in continuous tone Information Sounder Base Low Frequency Sounder Base Test Magnet Test Magnet Weight Power Voltage Power Standby B200S Power Standby B200S LF Power Alarm B200S Power Alarm B200S LF Operating Voltage Standby Alarm Current Temperature 5.08 cm less sensor 17.46 cm 50 lb 227gm 60 lb 272gm to 33 VDC VFWR mA maximum mA maximum mA maximum mA maximum to 32 VDC max base only 120 0 49 93 non document is not intended to be used for installation purposes We try to keep our product information and accurate We cannot cover all specific applications or anticipate all requirements All are subject to change without notice For more information contact Silent Knight 12 Road Northford CT 06472 1610 Phone 800 328 0103 Fax 203 484 7118 Technical Support Please call 800 446 6444 www farenhyt com

Related Files