Farenhyt ECS-550

File Preview
File Preview
Click below to download for free

File Data

Name farenhyt-ecs-550-7584032169.pdf
Type PDF
Size 918.17 KB
Downloads

Text Preview

Emergency Communication System ECS 550 is a multipurpose emergency voice evacuation panel may be used for fire applications mass notification applications or This state of the art ECS 550 is capable of producing 50 or 100 of audio power that can be distributed up to eight speaker i e zones The ECS 550 comes standard with a single zone output and a built in 25Vrms 50 watt amplifier A 50 watt amplifier ECS BD50 25V 70V can be added for purposes or for an additional 50 watts of audio power that will allocated across available speaker zones In addition an optional module can be added to the ECS 550 to upgrade the to include a maximum of eight speaker zone outputs Other messaging features include the ability to record up to fourteen programmable messages up to 60 seconds each by using an microphone or from an external audio source Knights fully supervised external data bus on the ECS 550 for the connection of up to eight control devices and eight audio circuits that provide a maximum of up to 24 speaker to meet the needs of even the largest and most complex The ECS 550 is capable of supporting most retrofit by providing a speaker circuit output of 70.7Vrms with the of a built in amplifier converter ECS XRM 70V or by adding additional secondary 70.7VDC amplifier module ECS BD50 70V backup amplifier protection re routes power to a backup in the event of a primary amplifier failure ECS 550 offers the flexibility to be used as an adjunct slave to UL listed FACPs or as standalone unit to provide fire protection emergency voice evacuation As an added benefit for fire alarm an on board fully supervised Notification Appliance NAC provides 2.0 Amps of synchronized NAC power while most synchronization protocols In addition the ECS 550 be activated by a building Private Branch Exchange PBX by the integral Night Ring feature To activate the ECS 550 from any location the ECS RTZM option module provides access to the system via cell phone or other remote telephone UL Listed to UL2572 Communication and Control Units Mass Systems Pending Up to 14 recorded messages Modular design for maximum system flexibility and easy expansion Removable terminal blocks for ease of servicing and module 50 watts of 25 V audio power expandable to 100 watts RMS 2 amp Notification Appliance Circuit NAC output sync generator or for System Sensor Wheelock or Gentex protocols Optional 70.7 V RMS conversion transformer available for the amplifier Note that speaker wiring continues to be in standby alarm and when background music is playing this optional transformer installed External Audio Input can be used for background music Up to 60 second message duration for all messages Communication System Listings Eight Command Input Circuits to activate 1 to 8 CMD1 and CMD2 are field selectable to activated from 12 or 24 VDC Notification Circuits reverse polarity or closures CMD3 CMD8 are activated by contact Speaker Circuits Single Style Y Class B or Style Z Class speaker Circuit Two Style Y Class B or Style Z Class A circuits with optional ECS BD50 Audio Amplifier installed Eight Style Y Class B or Style Z Class speaker circuits with optional ECS and ECS CE6 installed Integral supervised microphone Microphone time out feature which reverts back pre recorded message if emergency page the programmed time Standard pre recorded message I have attention please May I have your please The signal you have just indicates a report of a fire in this Please proceed to the nearest exit leave the building Do not re enter the unless directed to do so by the proper 350609 Rev A 2013 Honeywell International Inc cont Field selectable message and custom message recording using the local microphone a USB port or an audio input Integral tone generators field selectable for steady slow high low or chime tones Powered by integral AC power supply or batteries during AC Programmable delay of immediate 2 hours or 6 hours of AC Loss Piezo sounder for local trouble 100 event history log Three Form C relays AC Power Loss Relay TB1 System Trouble Relay TB2 Audio System Active TB3 500mA 0.5A Special Application auxiliary power output for modules when interfaced with compatible FACPs and End of Line power supervision Integral Dress Panel AC POWER 120 VAC 50 60 Hz 3.0 amps HOT NEU size minimum 14 AWG 2.00mm2 with 600 V insulation POWER BATTERY CHARGING CIRCUIT Supports lead acid batteries only Float charge voltage at 27.3V Maximum charge current 1.0 Amp Maximum battery charge capability 26AH ECC cabinet max 18AH battery Minimum Battery size 12 Amp Hour LOSS RELAY CONTACT RATING 2.0 amps 30 VDC resistive 0.5 amps 30 VAC RELAY CONTACT RATING 2.0 amps 30 VDC resistive 0.5 amp 30 VAC ACTIVE RELAY CONTACT RATING 2.0 amps 30 VDC resistive 0.5 amps 30 VAC OUTPUT RATING TB19 TERMINALS 1 B 2 A 3 4 B One 1 Style Y Class B or Style Z Class A circuit Special Application power Power limited circuitry supervised Nominal operating voltage 24 VDC Maximum signaling current for special application power 2.0A Maximum signaling current for regulated power 200mA Current limit fuse less electronic power limited End Of Line Resistor 4.7 KW watt required for Style Y B operation SYNC TB18 TERMINALS 3 IN 4 IN 1 2 OUT Connections for FACP NAC synchronization trigger signal Output terminals pass through to other system components Trigger input voltage 9 to 32 VDC 24 VDC rated Input current draw in Alarm condition 10 mA at rated APPLICATION POWER AUX POWER TB17 1 2 500 mA 24 VDC Used for powering addressable modules and associated power supervision relays VOLUME CONTROL OVERRIDE TB23 1 B 2 A 3 A 4 B Style Y Class B or Style Z Class A circuit Special Application power Power limited circuitry supervised Nominal operating voltage 24 VDC Maximum signaling current 0.25 amps Current limit fuse less electronic power limited End Of Line Resistor 4.7 KW watt required for Style Y B operation Circuits SPEAKER CIRCUIT TB20 1 2 Style Y Class B 4 5 Style Z A 3 Shield Standby and Alarm Polarity Shown on control board SPEAKER CIRCUIT WITH OPTIONAL ONLY TB21 1 2 Style Y Class B 4 5 Style Z A 3 Shield Standby and Alarm Polarity Shown on control board Power limited circuitry Operation Circuit can be wired Style Y Class B or Z Class A Normal Operating Voltage 25 VRMS 2 amps max and Load Impedance of 12.5W 70.7 VRMS 700 max with maximum load Impedance of 100W possible by plugging optional ECS XRM 70V transformer into J12 of the main control board Output Power 50 watts 20 watts when background music employed Frequency Range 400Hz 4,000Hz Maximum total capacitance for each speaker circuit 250 End of Line Resistor required for Style Y circuit KW 1 watt Input Circuits alarm polarities shown TB4 Terminals 3 4 are input terminals and 1 and 2 are output terminals which provide through of the NAC circuits to NAC devices down TB5 Terminals 3 4 are input terminals and 1 and 2 are output terminals which provide through of the NAC circuits to NAC devices down TB6 Terminals 1 2 are input terminals for closure only TB6 Terminals 3 4 are input terminals for closure only TB7 Terminals 1 2 are input terminals for closure only TB7 Terminals 3 4 are input terminals for closure only TB8 Terminals 1 2 are input termina

Related Files