Farenhyt IDP-Beam Reflected Beam Smoke Detector without Test Feature

File Preview
File Preview
Click below to download for free

Text Preview

Addressable Beam Smoke Detector IDP Beam T IDP Beam and IDP Beam T are addressable beam smoke for use with Silent Knight IFP series fire alarm control FACPs They are uniquely suited for protecting open with high ceilings where other methods of smoke detection difficult to install and maintain The IDP Beam T also an integrated sensitivity test feature of the single ended reflective design is much easier dual ended projected beam detectors Alignment is quickly using an optical sight and a two digit signal meter incorporated into the IDP Beam and IDP Beam T for operation from 22 to 131 30 to 55 the and IDP Beam T can be used in applications to early warning in environments where temperature exceed the capability of other types of smoke IDP Beam and IDP Beam T consist of a transmitter receiver and a reflector When smoke enters the area between the and the reflector it causes a reduction in the signal When smoke level reaches the predetermined threshold an alarm activated beam smoke detectors have four sensitivity selections with two Acclimate settings When either of the two settings are selected the detector will automatically its sensitivity using advanced software algorithms to select optimum sensitivity for the specific environment IDP Beam T is equipped with an integral sensitivity test that consists of a test filter attached to a servo motor the detector optics Using the remote test station System PN RTS451 the motor is activated and moves the in the pathway of the light beam which tests the detector This integral sensitivity test feature allows the user to and easily meet the annual maintenance and test of NFPA 72 16 to 328 foot protection range Single ended reflective design User friendly alignment procedure Six user selectable sensitivity levels Optional integral NFPA 72 sensitivity test feature Removable plug in terminal blocks Digital display for easy alignment Built in automatic gain control compensates for signal from dust build up Optional remote test station Rotary address switches for fast installation Paintable cover Listings Vol II IDP Beam and IDP Beam T can be mounted over recessed junction box or surface using the Silent Knight surface kit System Sensor PN The reflector is surface For applications in which the cannot be placed at the angle the multi mounting kit is System Sensor PN BEAMMMK IDP Beam and IDP Beam T are with the following FACPs IFP 2000 RPS 2000 Intelligent Fire IFP 2000ECS Emergency System with Fire Panel IFP 1000 ECS Intelligent Fire Panel IFP 100 ECS Intelligent Fire Panel IFP 50 Intelligent Fire 350282 Rev G 2015 Honeywell International Inc Range 16 328 5 100 m Angle horizontal vertical optics move of the unit Levels Level 1 Level 2 Level 3 4 Acclimate Level 1 to 50 Acclimate 2 to 50 Condition Trouble 96 or more obscuration blockage alignment mode improper alignment self compensation limit Aid Optical gunsight integral signal strength 2 digit display Normal green Yellow Red Feature Integral sensitivity test filter IDP Beam T sensitivity filter incremental scale on reflector local test local reset switch remote test and reset switch with RTS151 and RTS151KEY test station 10 H 25.4 cm x 7.5 W 19.1 cm x 3.3 D 8.4 cm for 16 230 7.9 H 20 cm x 9.1 W 23 cm for Beyond 230 15.7 H 40 cm x 18.1 W 46 cm Weight 3.9 lbs 1.8 kg Temperature 22 131 30 55 10 93 non condensing Voltage 15 32 VDC current draw Standby Alarm 2mA Max current draw Standby 2mA Max 8.5mA Max During Testing Average 500 mA max Electrical Specifications Voltage 15 32V 450 mA max 34V per reflector Consumption 7.7W 24V 15W 32V per reflector Electrical Specifications Voltage 15 32V 92 mA 32V Consumption 1.6W 24V 3W 32V Information Smoke Detector Smoke Detector with Test Feature Range Accessory Kit Required for in excess of 230 ft 70m Kit Provides ceiling or wall capability with increased angular for either the beam or the When installed with the unit BEAMSMK must be used Mount Kit Test Station Used to initiate the sensitivity test function Test Station with Key Lock Kit for Transmitter Receiver Unit electrical requirements in the Kit for Reflector See electrical in the Specifications section document is not intended to be used for installation purposes We try to keep our product information and accurate We cannot cover all specific applications or anticipate all requirements All are subject to change without notice For more information contact Silent Knight 12 Road Northford CT 06472 1610 Phone 800 328 0103 Fax 203 484 7118 Technical Support Please call 800 446 6444 www farenhyt com

Related Files