Farenhyt IDP-Control-6 Six Circuit Supervised Control Module

File Preview
File Preview
Click below to download for free

Text Preview

Addressable Notification Module IDP Control 6 is an addressable notification module for use Silent Knight IFP series fire alarm control panels FACPs IDP Control 6 has six integrated modules for maximum allowing you to add notification circuits wherever they needed on an IFP FACP signaling line circuit SLC loop IDP Control 6 provides supervised monitoring of wiring to devices that require an external power supply or amplifier operate such as bells horns and strobes It is capable of Class B Style Y and Class A Style Z wiring command from the FACP the IDP Control 6 will the supervision and connect the external power across the load device The disconnection of the provides a positive indication to the panel that the relay actually turned on The external power supply is relay isolated from the SLC loop so that a trouble on the power supply will never interfere with the rest of system needed you can disable a maximum of three unused modules the IDP Control 6 board Each module has terminals for to an external supply circuit for powering devices on notification appliance circuit NAC One or more multiple supplies or amplifiers can be used IDP Control 6 has a short circuit protection monitor for each The short circuit protection monitor protects external supplies against short circuit conditions on the NAC In an algorithm is incorporated to find a short when the is active The module will close all circuits that are not to find the NAC with the problem Flexible solution for adding notification circuits where needed Removable 12 to 18 AWG plug in terminal blocks Support for Class B or Class A wiring Individual LED for each module Two module mounting in the IDP ACB cabinet Unused modules can be disabled Rotary address switches for fast installation Mounting hardware included UL Listed MEA CSFM approved Listings Vol 2 IDP Control 6 mounts in the Silent IDP ACB cabinet PN IDP ACB IDP ACB has a built in chassis that accommodate one or two IDP modules IDP Control 6 is compatible with the FACPs IFP 2000 RPS 2000 Intelligent Fire IFP 2000ECS Emergency System with Fire Panel IFP 1000 ECS Intelligent Fire Panel IFP 100 ECS Intelligent Fire Panel 350294 Rev G 2015 Honeywell International Inc Rating Per Circuit 63W 70.7 VAC 25 VAC Resistance 47K W Information Input Notification Module Module Cabinet Cabinet holds two 6.8 17.3 cm 5.8 14.7 cm 1.25 3 cm Weight 6.3 oz 196 g 38.7 cm 31.8 cm 7.6 cm lbs 2.8 kg Temperature 32 120 0 49 10 93 non condensing Voltage 15 32 VDC Power Supply 8mA max in standby 20mA max in alarm Standby Alarm Current 2.25 mA max NAC Circuit Line Loss 4 VDC document is not intended to be used for installation purposes We try to keep our product information and accurate We cannot cover all specific applications or anticipate all requirements All are subject to change without notice For more information contact Silent Knight 12 Road Northford CT 06472 1610 Phone 800 328 0103 Fax 203 484 7118 Technical Support Please call 800 446 6444 www farenhyt com

Related Files