Farenhyt IDP-Zone-6 Six Zone Interface Module

File Preview
File Preview
Click below to download for free

File Data

Name farenhyt-idp-zone-6-six-zone-interface-module-9216453078.pdf
Type PDF
Size 751.87 KB
Downloads

Text Preview

Addressable Two Wire Interface Module IDP Zone 6 is an addressable zone interface module for use Silent Knight IFP series fire alarm control panels FACPs provides six zone inputs that allow a Silent Knight to interface and monitor two wire conventional smoke This means you can retrofit an existing building and existing conventional devices inputs on the IDP Zone 6 share a common FACP signaling circuit SLC input and the initiating device circuits share a external power supply Otherwise each input on the operates independently from the others If needed you disable a maximum of two unused inputs on the IDP Zone 6 transmits the status of a zone of two wire detectors to the Status conditions are reported as normal open or alarm supervises the zone of detectors and the connection the external power supply two wire detectors being monitored must be UL compatible the IDP Zone 6 Converts a conventional two wire loop to an SLC loop Six zone inputs Fully supervised Support for Class B and Class A wiring Removable 12 to 18 AWG plug in terminal blocks Individual LED for each relay contact Two module mounting in the IDP ACB cabinet Up to two unused modules can be disabled Rotary address switches for fast installation Mounting hardware included UL Listed Listings 2 IDP Zone 6 mounts in the Silent IDP ACB cabinet PN IDP ACB IDP ACB has a built in chassis that accommodate one or two IDP Zone 6 IDP Zone 6 is compatible with the FACPs IFP 2000 RPS 2000 Intelligent Fire IFP 2000ECS Emergency System with Fire Panel IFP 1000 ECS Intelligent Fire Panel IFP 100 ECS Intelligent Fire Panel IFP 50 Intelligent Fire a list of detectors compatible with the see the IDP Zone 6 Instructions PN I56 2733 00 350297 Rev F 2015 Honeywell International Inc Power Supply Current 50 mA Current 70 mA per module Resistance 3.9k W Information Zone Two Wire Interface Module Module Cabinet Cabinet holds two 6.8 17.3 cm 5.8 14.7 cm 1.0 2.5 cm Weight 6.3 oz 196 g 38.7 cm 31.8 cm 7.6 cm lbs 2.8 kg Temperature 32 120 0 49 10 93 non condensing Voltage 15 32 VDC Standby Alarm Current 2 mA max Loop Resistance 40W max Device Circuit Supervised power limited IDC Wiring Resistance 25W max document is not intended to be used for installation purposes We try to keep our product information up and accurate We cannot cover all specific applications or anticipate all requirements All specifications subject to change without notice For more information contact Silent Knight 12 Clintonville Road CT 06472 1610 Phone 800 328 0103 Fax 203 484 7118 Technical Support Please call 800 446 6444 www farenhyt com

Related Files