Farenhyt IFP-100 Analog Addressable FACP Data Sheet

File Preview
File Preview
Click below to download for free

File Data

Name farenhyt-ifp-100-analog-addressable-facp-data-sheet-2397086145.pdf
Type PDF
Size 676.12 KB
Downloads

Text Preview

Intelligent Fire Alarm Control Panel is an intelligent analog addressable fire control panel The IFP 100 system has a single SLC loop and four notification circuits that can be programmed for notification outputs or power IFP 100 also has a built in dual line digital fire Form C trouble relay and two programmable Form C The firmware has powerful features such as detector day night thresholds drift compensation and pre trouble alert supports a variety of other devices that can be added to the such as RA 100 remote annunciator 5824 serial parallel interface module for printing system reports and 5496 power module and SD or IDP Protocol devices Built in support for up to127 SD devices or 99 IDP detectors and 99 modules Uses standard wire shielded or twisted pair required Built in digital communicator for remote reporting of system activity system programming using either SIA or CID formats Central station reporting by point or by zone Jumpstart auto programming Supports Class B Style 4 and Class A Style 6 or Style 7 for SLC Distributed intelligent power Built in synchronization for AMSECO Gentex Faraday System and Wheelock appliances Sensor sensitivity settings and day night sensitivity setting Automatic drift compensation Notification circuits configurable as 2 Class A Style Z 4 Class B Y or auxiliary power for resettable constant or door holder Built in annunciator with a backlit 80 character LCD display RS 485 bus provides communication to system accessories Built in Form C trouble relay rated at 2.5 amps at 27.4 VDC Two built in Form C programmable relays rated at 2.5 amps at 27.4 SLC device locator can be used to locate a single or multiple on a SLC loop System automatically performs detector sensitivity test 13 preset notification cadence patterns including ANSI 3.41 and user programmable patterns Built in RS 232 and USB interface for programming Upload or download programming event history or detector status or from a remote location using a PC and 5650 5651 Silent Software Suite SKSS Improvements in SKSS deliver five times faster upload downloads Non volatile event history stores up to 1000 events 125 Software zones and 125 output groups Programmable date setting for Daylight Saving Time Fire Alarm Control Panel Listings Vol XIV 6 amp power supply and maximum charging of 35 amp hours An additional cabinet is required for batteries in excess of amp hours Integrated dead front panel protects operator exposure to electrical components The FACP enclosure features a Plexiglass window to protect annunciator Programmable to automatically display oldest first or display tally of system events Acknowledge function allows operator to keep of event status IFP 100 can be surface or flush mounted IFP 100 SLC supports multiple device types of same protocol SD IDP cannot mix SD and IDP devices on a FACP SD Devices data sheet PN 350360 and IDP Protocol Devices data sheet PN 350361 350388 Rev K 2013 Honeywell International Inc Releasing Solenoids Number VDC 3 A VDC 3 A Information Fire Alarm Control Panel Accessories 5865 4 Annunciator Same operation and appearance to FACP annunciator Annunciator Four line LCD with 20 characters per line Annunciator Four line LCD with 20 characters per line Power Module Power Module Printer Interface Module I O Module Fire Annunciators Board and IDP Devices the specification sheets listed below for a complete listing the SD and IDP devices Accessories Devices Specification Sheet Devices Specification Sheet Knight Software Suite Provides upload download and event Knight Software Suite Provides monitoring Battery Box Accessory Cabinet if backup batteries are too large to fit FACP cabinet Dimensions W x 10 H x 6 D mm W x 254 mm H x 152 mm D Compliance Kit Mount Dimensions 14.5 x 24.75 x 3.5 W x 62.9 H x 8.73 D cm x 26.4 x 4.65 W x 67 H x 11.8 D cm Dimensions 28 lbs 12.8 kg Red Temperature 32 120 0 49 10 93 non condensing AC 120 VRMS 50 60 Hz 2.5A Accessory Load 6A 27.4 VDC power limited Current 170 mA Current 325 mA Charging Capacity 7 to 35 AH Size 18 AH max allowed in control panel cabinet capacity batteries can be housed in RBB accessory Appliance Circuits circuits that can be programmed individually as Circuits 3A per circuit 27.4 VDC power limited Power Circuits 3A per circuit 27.4 VDC Lights Red Flashes when in alarm solid when alarm silenced Yellow Flashes when a supervisory condition solid when supervisory silenced Yellow Flashes when a trouble condition exists solid trouble silenced Yellow Solid when an alarm trouble or supervisory has been silenced but not yet cleared Green Flashes for AC failure solid when power are normal FCC Part 15 Part 68 approved RJ31X two required 13 NFPA 15 NFPA 16 NFPA 70 72 Central Station Remote Signalling Local Protective Systems Auxiliary Protected Premises Unit Water Releasing Service Suitable for automatic manual sprinkler supervisory DACT non coded signalling Approvals UL Listed CSFM 7165 0559 0142 429 92 E Vol XIV OSHPD CA OSP 0065 10 document is not intended to be used for installation purposes We try to keep our information up to date and accurate We cannot cover all specific applications anticipate all requirements All specifications are subject to change without notice more information contact Silent Knight 12 Clintonville Road Northford CT 06472 Phone 800 328 0103 Fax 203 484 7118 For Technical Support please call www farenhyt com in the U S A

Related Files