Farenhyt IFP-1000 Analog Addressable FACP Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | farenhyt-ifp-1000-analog-addressable-facp-data-sheet-5132764980.pdf |
---|---|
Type | |
Size | 678.50 KB |
Downloads |
Text Preview
Analog Addressable Alarm Control System IFP 1000 and IFP 1000HV are intelligent analog addressable fire control panels FACPs The basic IFP 1000 system has one line circuit SLC loop that supports up to seven 5815XL signal circuit expanders The IFP 1000HV offers the same functionality features as the IFP 1000 but is configured for 240 VAC operation has six on board Flexput circuits that can be for auxiliary power notification outputs or for conventional detector inputs Class A or Class B The FACP also has a dual line digital fire communicator Form C trouble relay and programmable Form C relays The firmware has powerful features as detector sensitivity day night thresholds drift compensation maintenance alert and calibration trouble alert supports a variety of devices including RA 1000 remote 5824 serial parallel printer interface module for printing reports RPS 1000 intelligent power module and Hochiki or Device Protocol IDP devices Built in support for up to 127 Hochiki devices or 99 IDP detectors 99 IDP modules expandable to 1016 Hochiki devices or 792 detectors and 792 IDP modules Uses standard wire shielded or twisted pair required Built in UL listed digital communicator for remote reporting of system and system programming Central station reporting by point or by zone Supports Class B Style 4 and Class A Style 6 or Style 7 for SLC and SBUS Distributed intelligent power Sensor sensitivity settings day night sensitivity setting and automatic compensation Flexput I O circuits configurable for auxiliary power notification or conventional smoke detector inputs Notification circuits be configured as Class A Style Z or Class B Style Y 2 and smoke detectors can be configured as Class A Style D or B Style B Built in annunciator with a backlit 80 character LCD display RS 485 bus provides communication to system accessories Built in RS 232 and USB interface for programming Upload or download programming event history or detector status or from a remote location using a PC and 5650 5651 Silent Software Suite SKSS Improvements in SKSS delivers five times faster upload downloads Built in Form C trouble relay rated at 2.5 amps at 27.4 VDC Two built in Form C programmable relays rated at 2.5 amps at 27.4 Individual addressable devices can be tested SLC device locator can locate a single or multiple devices on a SLC System automatically tests addressable devices Fire Control Panel Listings IX 13 preset notification cadence patterns ANSI 3.41 and four user patterns Programmable to automatically display initial first or display tally of system events Built in synchronization for appliances from System Sensor Faraday Gentex Wheelock Acknowledge function allows operator to keep of event status Jumpstart auto programming Modular design Nonvolatile event history stores up to 1000 125 software zones and 250 output groups 6 amp power supply and maximum charging of 35 amp hours An additional enclosure is required for batteries in of 18 amp hours Programmable date setting for Daylight Saving Plex 1 door option combines a dead front door with a clear window limiting to the panel while providing single operation of the reset and silence 350093 Rev L 2013 Honeywell International Inc IFP 1000 HV can be surface or flush mounted IFP 1000 HV SLC supports multiple device types of the protocol IDP or Hochiki cannot mix Hochiki and IDP devices on a FACP any combination of addressable devices of the protocol can be used on the IFP 1000 HV Mount Dimensions 14.5 x 24.75 x 3.9 Dimensions W x 62.9 H x 9.8 D cm x 26.4 x 4.2 W x 67 H x 11.8 D cm 28 lbs 12.8 kg Red Temperature 32 120 0 49 10 93 non condensing Primary AC 120 VRMS 50 60 Hz 2.7A Primary AC 240 VRMS 50 60 Hz 1.4A Accessory Load 6A 27.4 VDC power limited Current 215 mA Current 385 mA Charging Capacity 7 to 35 AH Size 18 AH max allowed in control panel cabinet capacity batteries can be housed in RBB accessory Circuits circuits that can be programmed individually as Circuits 3A per circuit 27.4 VDC power limited Power Circuits 3A per circuit 27.4 VDC power Circuit 100 mA per circuit 27.4 VDC power Lights Alarm Red Flashes when in alarm solid when silenced Yellow Flashes when a supervisory condition solid when supervisory silenced Troubles Yellow Flashes when a trouble condition solid when trouble silenced Silenced Yellow On when an alarm trouble or condition has been silenced but not yet cleared Power Green Flashes for AC failure solid when systems are normal FCC Part 15 Part 68 approved RJ31X two required 13 NFPA 15 NFPA 16 NFPA 70 72 Central Station Remote Signalling Local Signalling Systems Auxiliary Protected Premises Water Deluge Releasing Service Suitable for manual waterflow sprinkler supervisory DACT signalling services Approvals UL Listed CSFM 7170 0559 135 429 92 E Vol IX FM Approved OSHPD CA OSP Releasing Solenoids Number Information Current Freq VDC 3 A max 0 Hz VDC 3 A max 0 Hz Fire Alarm Control Panel Fire Alarm Control Panel High 240 VAC Accessories Annunciator Similar in and appearance to FACP Gray Annunciator Similar in and operation to FACP Red Annunciator Four line LCD with 20 characters per line Line Circuit SLC Expander Power Module Power Module Printer Interface Module I O Module Fire Annunciators Board 5865 4 and IDP Devices the specification sheets listed below for a complete of the Hochiki and IDP devices Devices Specification Sheet Device Protocol Devices Sheet Accessories Knight Software Suite Provides upload download and reporting Knight Software Suite Provides monitoring Accessory Dead front cabinet door clear window to limit access to Battery Box Accessory Cabinet if backup batteries are too large to into FACP cabinet Dimensions W x 10 H x 6 D 406 mm W x 254 H x 152 mm D Compliance Kit document is not intended to be used for installation purposes We try to keep our information up to date and accurate We cannot cover all specific applications anticipate all requirements All specifications are subject to change without notice more information contact Silent Knight 12 Clintonville Road Northford CT 06472 Phone 800 328 0103 Fax 203 484 7118 www farenhyt com in the U S A