Farenhyt IFP-1000 City of Chicago Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | farenhyt-ifp-1000-city-of-chicago-data-sheet-3210984765.pdf |
---|---|
Type | |
Size | 1.16 MB |
Downloads |
Text Preview
Analog Addressable Alarm Control Panel of Chicago Class 1 Addressable Approved is an intelligent analog addressable fire alarm control panels The basic IFP 1000 system has one signal line circuit SLC loop supports up to seven 5815XL signal line circuit expanders has six on board Flexput circuits that can be configured for power notification outputs or for conventional smoke detector Class A or Class B The FACP also has a built in dual line digital communicator Form C trouble relay and two programmable Form C The firmware has powerful features such as detector sensitivity thresholds drift compensation pre trouble maintenance alert and trouble alert supports a variety of devices including RA 1000 remote 5824 serial parallel printer interface module for printing reports RPS 1000 intelligent power module and Hochiki or Device Protocol IDP devices Built in support for up to 127 Hochiki devices or 99 IDP detectors and 99 modules expandable to 1016 Hochiki devices or 792 IDP detectors 792 IDP modules Uses standard wire shielded or twisted pair required Built in UL listed digital communicator for remote reporting of system and system programming Central station reporting by point or by zone Supports Class B Style 4 and Class A Style 6 or Style 7 configuration SLC and SBUS Distributed intelligent power Sensor sensitivity settings day night sensitivity setting and automatic drift Flexput I O circuits configurable for auxiliary power notification outputs conventional smoke detector inputs Notification circuits can be as Class A Style Z or Class B Style Y 2 and 4 wire smoke can be configured as Class A Style D or Class B Style B Built in annunciator with a backlit 80 character LCD display RS 485 bus provides communication to system accessories Built in RS 232 and USB interface for programming Upload or download programming event history or detector status onsite from a remote location using a PC and 5650 5651 Silent Knight Suite SKSS Improvements in SKSS delivers five times faster upload downloads Built in Form C trouble relay rated at 2.5 amps at 27.4 VDC Two built in Form C programmable relays rated at 2.5 amps at 27.4 VDC SLC device locator can locate a single or multiple devices on a SLC loop System automatically tests addressable devices 13 preset notification cadence patterns including ANSI 3.41 and four programmable patterns Programmable to automatically display initial event first or display tally of events Fire Control Panel Chicago Built in synchronization for appliances from Gentex Faraday System and Wheelock Acknowledge function allows operator to track of event status Jumpstart auto programming Nonvolatile event history stores up to 1000 125 software zones and 250 output groups 6 amp power supply and maximum capacity of 35 amp hours An cabinet enclosure is required for in excess of 18 amp hours Programmable date setting for Daylight Time Plex 1 door option combines a dead front door with a clear window limiting to the panel while providing single operation of the reset and silence can be surface or flush mounted SLC supports multiple device types the same protocol Hochiki or IDP You mix Hochiki and IDP devices on a However any combination of devices of the same protocol can used on the IFP 1000 the specification sheets listed below for a listing of IDP and Hochiki devices Hochiki Device Data Sheet Intelligent Device Protocol IDP sheet 350336 Rev C 2010 Honeywell International Inc is a Trademark of Silent Knight is a Registered Trademark of Silent Knight Battery Box Accessory Cabinet Information Disconnect Switch used to disconnect the fire alarm panel reporting any alarm or trouble condition to the city in order test and maintain the fire alarm system When the key switch turned to the Disconnect position a white pilot light illuminates inform the user that the panel has been disconnected Alarm Trouble Bell module used to silence and test the fire trouble bell When the fire alarm system is in trouble the will ring Moving the toggle switch to Bell Silence will silence bell and activate the Bell Silenced LED Tie Trouble module used to silence and test city tie troubles When the CTD2G key switch is in the position the City Tie Trouble bell will ring Moving toggle switch to Bell Silence will silence the bell and activate Bell Silenced LED the above parts contact the following vendor Inc 8828 S Archer Ave IL 60480 800 871 6840 Equipment Required equipment listed below is required to comply with Class I requirements Silent Knight Plex 1 Door Front Cabinet Door An incandescent backlit annunciator Contact the vendor listed for the custom model XL8 Tabular Annunciator with the Knight 5880 LED I O Module Age Electronics Inc 406 Lincoln Street MA 01752 800 486 1723 Mount Dimensions 14.5 x 24.75 x 3.9 Dimensions W x 62.9 H x 9.8 D cm x 26.4 x 4.2 W x 67 H x 11.8 D cm 28 lbs 12.8 kg Color Red Temperature 32 120 0 49 10 93 non condensing AC 120 VRMS 50 60 Hz 2.7A Accessory Load 6A 27.4 VDC power limited Current 140 mA Current 260 mA Charging Capacity 7 to 35 AH Size 18 AH max allowed in control panel cabinet Larger batteries can be housed in RBB accessory cabinet Circuits circuits that can be programmed individually as Circuits 3A per circuit 27.4 VDC power limited Power Circuits 3A per circuit 27.4 VDC power Circuit 100 mA per circuit 27.4 VDC power limited FCC Part 15 Part 68 approved RJ31X two required Building Code Requirements models CTD2G CITY and FIRE are designed to comply with and addressable Class I type building requirements the City of Chicago Illinois They provide the ability to perform of the system trouble bell and the city tie disconnect bell They also allow disconnecting of the municipal tie fire box For City of Chicago fire alarm projects a fire alarm review and permit are required 13 NFPA 15 NFPA 16 NFPA 70 72 Central Station Remote Signalling Local Protective Systems Auxiliary Protected Premises Unit Water Releasing Service Approvals UL Listing CSFM 7170 0559 135 429 92 E Vol VI FM Approved City of Chicago Class 1 Approved Ordering Information Accessories 5865 4 Accessories Line Circuit SLC Expander Power Module I O Module Fire Annunciators Fire Alarm Control Panel Knight Software Suite Provides upload download and event Accessory Dead front cabinet door clear window to limit access to panel Tabular Annunciator from Space Age Electronics document is not intended to be used for installation purposes We try to keep our information up to date and accurate We cannot cover all specific applications or all requirements All specifications are subject to change without notice For more contact Silent Knight 12 Clintonville Road Northford CT 06472 1610 Phone Fax 203 484 7118 www farenhyt com in the U S A