Farenhyt IFP-2000 RPS-2000 Analog Addressable FACP Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

Scalable Analog Addressable Alarm Control System RPS 2000 IFP 2000 is an intelligent analog addressable fire alarm panel FACP The basic IFP 2000 panel contains one in signaling line circuit SLC which can support 159 IDP and 159 IDP modules or 127 SD devices per loop SLC loops can be added using the model 5815XL expander to increase the overall point capacity to a of 636 points per panel has the interconnection capability for up to 16 panels system has two modes of operation Multiple panels one larger building or multiple independent buildings is used in a networked system where at least one is in the system It is the same as an IFP 2000 the display has eight on board Flexput circuits that can be for auxiliary power notification outputs or for smoke detector inputs Class A or Class B The also has a built in dual line digital fire communicator C trouble relay and two programmable Form C relays has powerful features such as detector sensitivity thresholds drift compensation pre trouble alert and calibration trouble alert supports a variety of devices including RA 2000 annunciator 5824 serial parallel printer interface module event logging system reports RPS 1000 intelligent power and IDP or SD protocol SLC devices Built in support for up to 159 IDP sensors and 159 IDP or 127 SD devices SLC devices SLC expander will overall capacity to 636 points per IFP 2000 panel RPS 2000 is used in a networked system where at least one is in the system Up to 16 IFP 2000 or RPS 2000 panels can be networked up to 10,176 total points Networked panels can be configured to emulate a large system or can be segmented into separate sites for building applications Built in UL listed digital communicator for remote reporting of activity and system programming 9.0A of output power is available through 8 sets of terminals notification and auxiliary applications per panel Supports Class B Style 4 and Class A Style 6 or Style 7 for SLC and SBUS JumpStart auto programming allows for faster set up time by default options for many programming tasks System automatically tests IDP addressable devices 999 software zones and 999 output groups Fire Control Panel Listings of Flexput I O circuits configurable for power notification outputs or smoke detector inputs circuits can be configured as A Style Z or Class B Style Y 2 4 wire smoke detectors can be as Class A Style D or Class B B Two RS 485 buses provide to system accessories Built in USB interface for programming Dedicated Form C trouble relay and two purpose Form C programmable rated at 2.5 amps at 24 VDC 13 preset notification cadence patterns ANSI 3.41 and four user patterns Four line LCD display with 40 characters line Built in synchronization for appliances AMSECO Gentex System and Wheelock Programmable date setting for Daylight Time The IFP 2000 RPS 2000 can be surface flush mounted Four programmable function keys 350028 Rev G 2013 Honeywell International Inc Mount Dim 14.75 x 25 x 4 W x 63.5 H x 10.16 D cm Dimensions 16 x 26.4 x 4.65 W x 67 H x 11.8 D cm 28 lbs 12.8 kg Red Temperature 32 120 0 49 10 93 non condensing AC 120 VAC 50 60 Hz 5.0A AC 240 VAC 50 60 Hz 2.5A Accessory Load 9A 24 VDC power limited Current 290 mA Current 530 mA Charging Capacity 17 to 55 AH Size 18 AH max allowed in control panel cabinet capacity batteries can be housed in RBB or AB 55 cabinet Circuits circuits that can be programmed individually as Circuits 3A per circuit 24 VDC power limited Power Circuits 3A per circuit 24 VDC power Circuit 100 mA per circuit 24 VDC power limited Lights Alarm Red On when in alarm Yellow On when a supervisory condition exists Troubles Yellow On when a trouble condition exists Silenced Yellow On when an alarm trouble or condition has been silenced but not yet cleared Power Green Off for AC failure On when power are normal FCC Part 15 Part 68 approved RJ31X two required 13 NFPA 15 NFPA 16 NFPA 70 NFPA 72 Central Remote Signalling Local Protective Signalling Auxiliary Protected Premises Unit Water Deluge Service Suitable for automatic manual waterflow supervisory DACT non coded signalling services Approvals UL Listed FM Approved City of New York and OSHPD CA OSP 0065 10 Current Freq VDC 3 A max 0 Hz VDC 3 A max 0 Hz number Releasing Solenoids Information Fire Alarm Control Panel Voltage 240VAC Intelligent Fire Control Panel Fire Alarm Control Panel built in display Voltage 240VAC Intelligent Fire control Panel without built in Accessories Remote Annunciator Four line LCD with 40 characters per line Remote Annunciator Four line LCD with 40 characters per line Line Circuit SLC Expander amp Intelligent Power Module with 6 amp intelligent Power Module Printer Interface Module I O Module Fire Annunciators Board 5865 4 Devices the specification sheets listed below for a complete of the IDP devices Device Protocol devices sheet Devices the specification sheets listed below for a complete of the SD devices Device Protocol devices sheet Accessories repeater board for fiber optic repeater board for twisted pair Wired twisted pair network repeater card cabinet kit optic network repeater card and kit Accessories Knight Software Suite 2 programming upload and event reporting Battery Box Accessory Cabinet for backup batteries up to 35 AH 16 W x 10 H x 6 D W x 25.4 H x 15.24 D cm Battery Box Accessory Cabinet for backup batteries that are AH 55AH 20 W x 12 H x 7.5 D W x 30.48 H x 19.05 D cm Compliance Kit document is not intended to be used for installation purposes We try to keep product information up to date and accurate We cannot cover all specific or anticipate all requirements All specifications are subject to change notice For more information contact Silent Knight 12 Clintonville Road CT 06472 1610 Phone 800 328 0103 Fax 203 484 7118 For Support please call 800 446 6444 www farenhyt com in the U S A

Related Files