Intelligent Fire Alarm Control Panel Farenhyt IFP 25 is a 25 point single loop addressable fire control communicator system The IFP 25 supports Fire Systems HFS or equivalent IDP protocol and modules The IFP 25 provides you with the value and performance of addressable sensing combined with exclusive built in digital that includes an easy to use interface With wheel addressable detectors modules and JumpStart the IFP 25 can be Life Safety operational without a programming tool Powerful features such as drift and maintenance alert are delivered in this FACP from Silent Knight Support for any combination of up to 25 Honeywell Fire HFS or equivalent IDP protocol detectors and Version 2.0 or higher SBUS support for two 5635 Remote Annunciators 2.0 or higher Built in digital communicator Report by zone Code wheel detectors and modules for faster installation 72 Drift compensation Maintenance alert region Point status meets calibrated smoke test requirements for Auto learn feature for easy programming Custom programming can be performed through FACP built browser No programming software required Uses standard wire no shielded or twisted pair required Central Station reporting up to five zones Built in synchronization for System Sensor AMSECO or Wheelock Two Style Y Class B notification appliance circuits NAC Two built in Form C programmable relays Built in Form C trouble relay IFP 25 SLC supports Honeywell Fire Systems HFS or IDP detectors and modules in any combination 2.0 or higher Fire Alarm Control Panel Listings of NY 6057 Primary AC 120 VAC 60 Hz 1.5A Primary AC 230 VAC 50 60 Hz 75A Accessory Load 2.0A 24 VDC Power 2.0A 24 VDC power Current 135 mA Current 220 mA Power Circuits 1.0A 24 VDC per circuit limited Charging Capacity 7.0 to 33.0 AH 18 AH for ULC Size 7 AH max allowed in FACP Larger capacity batteries can be in an RBB accessory cabinet 350138 Rev D 2014 Honeywell International Inc W x 15.2 H x 3.4 D W x 38.42 H x 8.57 D cm 11.5 lbs 5.2 kg Red FCC Part 15 Part 68 approved RJ31X two required 13 NFPA 15 NFPA 16 NFPA 70 72 Central Station Remote Signalling Local Protective Systems Auxiliary Protected Premises Unit Suitable automatic manual waterflow sprinkler supervisory DACT signalling services Approvals UL Listing ULC ETL CSFM of NY COA Information Intelligent FACP 120 VAC 60 Hz 1.5A Intelligent FACP 230 VAC 50 60 Hz 75A Red 80 character LCD remote annunciator White 80 character LCD remote annunciator Fire System Devices Photoelectric smoke detector Photoelectric smoke detector with thermal Photoelectric duct smoke detector with extended air range Fixed temperature thermal detector Mini monitor module Addressable relay module Addressable single action pull station Addressable dual action pull station Detectors and Modules Photoelectric smoke detector Photoelectric smoke detector with thermal Photoelectric duct smoke detector Addressable fixed temperature thermal detector Mini monitor module Addressable single action pull station Addressable dual action pull station Fault Isolator module Addressable relay module Accessories Battery Box Accessory Cabinet Use if backup are too large to fit into FACP cabinet Dimensions W x 10 H x 6 D panel trim ring Use to flush mount the panel H x 14.630 W document is not intended to be used for installation purposes We try to keep product information up to date and accurate We cannot cover all specific or anticipate all requirements All specifications are subject to change notice For more information contact Silent Knight 12 Clintonville Road CT 06472 1610 Phone 800 328 0103 Fax 203 484 7118 in the

Related Files