Farenhyt IFP-50 Analog Addressable FACP Data Sheet

File Preview
File Preview
Click below to download for free

File Data

Name farenhyt-ifp-50-analog-addressable-facp-data-sheet-1678942053.pdf
Type PDF
Size 683.47 KB
Downloads

Text Preview

Intelligent Fire Alarm Control Panel is an intelligent analog addressable fire control panel FACP has a single line circuit SLC loop for connecting addressable and modules and has two notification appliance circuits that be programmed for notification outputs or auxiliary power IFP 50 has a built in dual line digital fire communicator Form C trouble and two programmable Form C relays The firmware has features such as detector sensitivity day night thresholds compensation and pre trouble maintenance alert supports a variety of other devices that can be added to the such as RA 100 or RA 1000 remote annunciator 5824 printer interface module for printing system reports and intelligent power module and SD or IDP devices Built in support for up to 50 SD devices or 50 IDP detectors and 50 modules Uses standard wire shielded or twisted pair required Built in digital communicator for remote reporting of system activity system programming Central station reporting by point or by zone Jumpstart auto programming Supports Class B Style 4 and Class A Style 6 or Style 7 for SLC Distributed intelligent power Built in synchronization for appliances from AMSECO Gentex System Sensor and Wheelock Sensor sensitivity settings and day night sensitivity setting and drift compensation Notification circuits can be configured as 1 Class A Style Z 2 Class Style Y or auxiliary power for resettable constant or door holder Built in annunciator with a backlit 80 character LCD display RS 485 bus provides communication to system accessories Built in RS 232 interface for programming via PC Built in Form C trouble relay rated at 2.5 amps at 24 VDC Two built in Form C programmable relays rated at 2.5 amps at 24 SLC device locator can be used to locate a single or multiple on a SLC loop System automatically performs detector sensitivity test 13 preset notification cadence patterns including ANSI 3.41 and user programmable patterns Upload or download programming event history or detector status or from a remote location using a PC and 5650 5651 Silent Software Suite SKSS Improvements in SKSS deliver five times faster upload downloads Non volatile event history stores up to 1000 events 125 software zones and 125 output groups Fire Alarm Control Panel Listings Vol XVI 2.5 amp power supply and maximum charging of 35 amp hours An additional cabinet is required for batteries in excess of 7 hours Programmable date setting for Daylight Saving IFP 50 SLC supports multiple device types of same protocol SD IDP cannot mix SD and IDP devices on a FACP any combination of addressable devices the same protocol can be used on the IFP 50 12.75 x 15.2 x 3.4 W x 62.9 H x 9.8 D cm 11.5 lbs 5.2 kg Red 350328 Rev J 2014 Honeywell International Inc Temperature 32 120 0 49 10 93 non condensing AC 120 VRMS 50 60 Hz 2.7A Accessory Load 2.5A 27.4 VDC power limited Current 200 mA Current 365 mA Charging Capacity 7 to 35 AH Size 7 AH max allowed in control panel cabinet capacity batteries can be housed in RBB accessory Appliance Circuits circuits that can be programmed individually as Circuits 2.5A per circuit 27.4 VDC Power Circuits 2.5A per circuit 27.4 VDC Lights Red Flashes when in alarm solid when alarm Yellow Flashes when a supervisory condition solid when supervisory silenced Yellow Flashes when a trouble condition exists solid trouble silenced Yellow On when an alarm trouble or supervisory has been silenced but not yet cleared Green Flashes for AC failure solid when power are normal FCC Part 15 Part 68 approved RJ31X two required 13 NFPA 15 NFPA 16 NFPA 70 72 Central Station Remote Signalling Local Protective Systems Auxiliary Protected Premises Unit Water Releasing Service Suitable for automatic manual sprinkler supervisory DACT non coded signalling Approvals UL Listing CSFM 170 0559 144 429 92 E Vol XVI Releasing Solenoid Part Number Rating VDC 2.5A VDC 2.5A Information Accessories Fire Alarm Control Panel Annunciator Similar in operation appearance to FACP annunciator Annunciator Four line LCD with 20 characters per line Annunciator Four line LCD with 20 characters per line Power Module 6 amp power that provides four additional power notification appliance circuits Printer Interface Module one parallel and one RS 232 port for connecting a printer to I O Module Provides 40 LED eight normally open dry contacts and one piezo output Fire Annunciators Provides 30 LED outputs and a piezo Board Provides 10 purpose Form C relays Used with 5865 4 and IDP Devices the specification sheets listed below for a complete listing the SD and IDP devices Devices data sheet Device Protocol IDP Devices sheet Accessories Knight Software Suite Provides upload download and event Order 5650 for PC parallel port or 5651 for PC USB port Knight Software Suite Provides monitoring Battery Box Accessory Cabinet if backup batteries are too large to fit FACP cabinet Dimensions W x 10 H x 6 D 406 mm W x 254 H x 152 mm D panel trim ring Use to flush mount panel 16.975 H x 14.630 W document is not intended to be used for installation purposes We try to keep our information up to date and accurate We cannot cover all specific applications or all requirements All specifications are subject to change without notice For information contact Silent Knight 12 Clintonville Road Northford CT 06472 1610 800 328 0103 Fax 203 484 7118 For Technical support please call www farenhyt com in the U S A

Related Files