Farenhyt SD505-TCHB100 Hand Held Programmer

File Preview
File Preview
Click below to download for free

File Data

Name farenhyt-sd505-tchb100-hand-held-programmer-8695174203.pdf
Type PDF
Size 642.69 KB
Downloads

Text Preview

TCH B100 HAND HELD PROGRAMMER is designed for use with all analog sensors modules SETTING Install sensor onto programmer ensuring that sensor protrusions align with programmer grooves Press the left gray button to switch programmed on A battery check message will appear followed by the devices address Unprogrammed sensors will read address 127 Set the required address by incrementing the left and right gray buttons the display will show three red flashing dots if the address being programmed is different from the device current address When the desired address is present press the red button to store that address The three red dots on the display will no longer be present PARTS 9 Volt Battery Remote Programming Cables FEATURES Compact unit to use address setting and reading Can be used on both sensors and modules Has the diagnostic ability to display the value Over 8000 address settings from one battery Voltage 9 VDC 9 VDC 0.34 lbs 6 1 4 White America Corporation Village Drive Suite 100 Buena Park CA 90621 2268 714 522 2246 Fax 714 522 2268 Support 800 845 6692 or technicalsupport hochiki com latest revision at www hochiki com Programming Buttons BUTTONS LEFT GRAY BUTTON Power on Automatically reads the addresss of a sensor Subsequent operations will advance the device address by ten RIGHT GRAY BUTTON Power off Advances the device address by one RED BUTTON Stores the displayed address to the device and is used to read sensor analog levels NOTE Prior to programming ensure battery is connected Programming Cable Modules except DCP FRCME S Remote Jack Programming Cable A SENSOR Ionization sensors require a 30 second stabilization period before analog value reading should be taken Install the sensor and power up programmer as previously described on page 1 Press the button An will appear on the display followed by the analog value The value will be continuously updated for three minutes The photoelectric sensor should have a value displayed of between 56 63 The ionization sensor should have a value displayed of between 52 73 out of these ranges indicate that the sensor chamber has become contaminated Refer to technical for proper servicing instructions or return sensor to factory for servicing MESSAGES address setting operation On upon power up battery check Also on when battery is low Low battery good for up to 3,000 Attempting to set an address beyond 127 Attempting to program an address with no device connected Can not find device after power up Invalid sensor response Can not find the device program Device read error Fail during Analog value reading America Corporation TCH B100 Hand Held Programmer subject to change without notice

Related Files