Farenhyt Series Brochure

File Preview
File Preview
Click below to download for free

File Data

Name farenhyt-series-brochure-5638247901.pdf
Type PDF
Size 1.89 MB
Downloads

Text Preview

Fire Alarm and Emergency Systems Series Emergency Communications Systems Systems and IFP 1000ECS addressable re alarm controls combined with integrated Communications Systems The seamless combination re detection and emergency communication simpli es operation programming of the entire system Built in Digital Message Repeater Supports up to 8 50W or 125W Addressable Ampli ers for a maximum of 1000W per system Up to 64 mappable speaker circuits Built in digital communicator with up download capability Can select ECS message as priority over re 15 recordable messages that can be mapped to 8 ECS buttons Supports up to 7 ECS RCU The ECS RCU meets the requirements Programmable trigger inputs from an external source such as a Monaco system to either the VCM RVM or 5880 Up to 8 inputs available on each 5880 module Fire Alarm and ECS combined in one easy to program system an LOC Detector Module Module Wire and Input VCM or RVM Driver and Input Module Series Emergency Communications Systems Systems addressable re alarm controls combined with integrated Emergency Communications The seamless combination of re detection and emergency communication simpli es and programming of the entire system a maximum of 2000W per system Built in Digital Message Repeater Supports up to 16 50W or 125W Addressable Ampli ers Up to 64 mappable speaker circuits Built in digital communicator with up download capability Can select ECS message as priority over re 15 recordable messages that can be mapped to 8 ECS buttons Supports up to 7 ECS RCU The ECS RCU meets the requirements for an LOC Programmable trigger inputs from an external source such as a Monaco system Fire Alarm and ECS combined in one easy to program system either the VCM RVM or 5880 Up to 8 inputs available on each 5880 module addressable re alarm controls combined with integrated Emergency Communications The seamless combination of re detection and emergency communication simpli es and programming of the entire system a maximum of 1000W per system Built in Digital Message Repeater Supports up to 8 50W or 125W Addressable Ampli ers Up to 64 mappable speaker circuits Built in digital communicator with up download capability Can select ECS message as priority over re 15 recordable messages that can be mapped to 8 ECS buttons Supports up to 7 ECS RCU The ECS RCU meets the requirements for an LOC Programmable trigger inputs from an external source such as a Monaco system Fire Alarm and ECS combined in one easy to program system either the VCM RVM or 5880 Up to 8 inputs available on each 5880 module Fire Fighter Telephone System Fire Fighter Telephone System The most exible and reliable re telephone control system for re ghters use with re alarm systems providing supervision annunciation and control Control and annunciate up to 72 remote telephone jacks Up to 10 Fire Fighter Remote Handsets FFT RHS can be used local and remote telephone handsets communicate over the circuit and Hybrid Conventional Addressable all in one conventional control panel easy to install program and maintain 10 zones expandable to 30 zones 4 Noti cation Appliance Circuits 6 A power supply Programmable from built in touch pad Built in digital communicator Conventional Addressable 25 point panel is as easy to install a conventional panel with the intelligence of an addressable system Cost effective Perfect for smaller jobs such as sprinkler monitoring day care centers elevator recall or small retail locations Utilizes cost saving HFS devices 2 Zone Form C Alarm and Trouble relays 240 VAC primary SK 2E only 4 Zone Form C Alarm Supervisory and Trouble relays Optional module that converts all 4 IDCs and 2 NACs to Class A 240 VAC primary SK 4E only GSM and SMS technology Uses IP IP Fire Communicator GSM SMS Backup Triple path re alarm communicator utilizes communication as the primary communication with dual GSM technology as a backup Faster response time Connects directly to re alarm DACT circuit Saves the cost of telephone lines Communicates using cost effective IP connectivity yet switches to GSM cellular communications if the internet goes down or selectable to GSM cellular only or IP only Digital Fire Communicator One of the most popular communicators Works as a standalone unit or adjunct Fully supervised another Fire Alarm Control Panel Fire Communicator Uses IP communication as the primary communication Connects directly to re alarm DACT circuit or the 5104 Faster response time Saves the cost of telephone lines Series IFP 100 and IFP 1000 IFP Series of re products offers exible easy to use and re alarm control systems with the power of choice select the right size and accessories for the project Analog controls for detector sensitivity day night thresholds drift compensation and pre trouble maintenance alert User friendly software provides access to programming up downloading event history detector status test reports and much more Save money on wiring by using standard wire no shielded or twisted pair required Built in digital communicator and alarm reporting by point or zone Capable for water releasing service Capable of temporal 3 for re and temporal 4 for CO detection using IDP Fire CO detector Points IDP 50 50 SD supply Detector Module Module Expander Station Input Module Wire Circuits Flexible input or output circuit that you can conveniently program to be used for Noti cation Appliance Circuits Auxiliary Power or as a input circuit With auxiliary power it can be selected as constant power door power or resettable smoke power The Flexput circuits provide the versatility without the added expense of additional modules a perfect t for retro tting an existing conventional system when budgets are a concern and RPS 2000 powerful choice in re alarm controls the IFP 2000 Series offers the most exible and reliable system As standalone control panel it has the highest power and point capacity available in the Silent Knight portfolio the four Function Keys for maximum exibility in programming and operations For large projects to 16 panels can be networked together to accommodate current needs and allow for future growth 9A power supply One on board SLC with capacity of 159 detectors 159 modules Max SLC points 636 per panel or 10,176 per network 999 zones 999 groups 8 Flexputs Networking Options

Related Files