The SpectrAlert Advance Selectable Output Speaker Strobes Dual Voltage Evacuation Speakers SpectrAlert Advance Series of speakers and speaker strobes is to reduce ground faults The plug in design allows the to pre wire mounting plates and dress the wires before in the speakers The plastic cover prevents nicked wires by exposed speaker components design also allows faster installations with instant feedback ensure that wiring is properly connected rotary switches to select and power settings and 11 field selectable candela settings for and ceiling speaker strobes low total harmonic distortion of the SP speaker offers high fidelity output while the SPV speaker offers high volume sound output use in high ambient noise applications Advance makes installation easy Attach a universal mounting plate to a 4 x 4 x 2 1 8 back Flush mount applications are achievable without the for an extension ring Connect the notification appliance circuit or speaker wiring to PEMS terminals on the mounting plate Attach the speaker or speaker strobe to the mounting plate by the product tabs into the mounting plate grooves the device into position to lock the product pins into mounting plate terminals The device will temporarily hold place with a catch until it is secured with a captured screw Plug in design Protective cover isolates speaker components reduces faults Field selectable candela settings on wall and ceiling units Standard 15 15 75 30 75 95 110 115 High 135 150 177 185 Shorting spring on mounting plate tests continuity before settings Rotary switch simplifies field selection of speaker voltage and Universal mounting plate for wall and ceiling mount units Compatible with System Sensor synchronization protocol SP speakers offer high fidelity sound output SPV speakers offer high volume sound output Automatic selection of 12 or 24 volt operation at 15 and 15 75 No extension ring required Ceiling and wall mount application Optional tamper resistant Torx head screw included Devices Listings Temperature 32 to 120 to 49 Range 10 to 93 non condensing Wall Mount Speaker Strobe 6.0 x 5.0 x lens and speaker Speaker Strobe 6.0 x 5.0 x lens and speaker Speaker 6.0 x 5.0 x 2.8 Speaker 6.0 x 5.0 x 2.9 Ceiling Mount Speaker Strobe 6.8 x 4.7 lens and speaker Speaker Strobe 6.8 x 4.8 lens and speaker Speaker 6.8 x 2.8 Speaker 6.8 x 2.9 Voltage speakers 25 V or 70.7 V nominal Supervisory Voltage speakers 50VDC Flash Rate 1 flash per second Voltage strobes Regulated 12VDC FWR regulated 24DC FWR 351513 Rev A 2010 Honeywell International Inc Voltage Range includes fire alarm panels with sync 8 to 17.5V 12V nominal or 16 to 33V 24V Voltage with MDL Sync Module 9 to 17.5V 12V or 17 to 33V 24V nominal Range 400 to 4000 Hz 1 2 watts Specifications Advance speaker and speaker strobes shall to a 4 x 4 x 2 1 8 backbox A universal mounting shall be used for mounting ceiling and wall products notification appliance circuit and amplifier wiring shall at the universal mounting plate Also Advance speaker strobes when used with the Circuit Module accessory shall be powered from a notification appliance output and shall operate on a nominal 12 or 24volts used with the Sync Circuit Module 12 volt rated appliance circuit outputs shall operate between and 17.5 volts 24 volt rated notification circuit outputs shall operate between 17 and 33 Indoor SpectrAlert Advance products shall operate 32 and 120 from a regulated DC or full wave unfiltered power supply Speaker strobes shall have candela settings including 15 15 75 30 75 110 115 135 150 177 185 speaker shall be a System Sensor SpectrAlert Advance dual voltage transformer speaker capable of at 25.0 or 70.7 nominal Vrms It should be listed to 1480 and shall be approved for fire protective service The shall have a frequency range of 400 to 4000Hz and have an operating temperature between 32 and Speaker shall have power taps and voltage that are by rotary switches Strobe Combination speaker strobe shall be a System Sensor SpectrAlert model listed to UL1480 and UL 1971 be approved for fire protective signaling systems shall be capable of operating at 25.0 or 70.7 nominal selected via rotary switch and shall have a frequency of 400 to 4000Hz Speaker shall have power taps are selected by rotary switch The strobe shall comply the NFPA 72 requirements for visible signaling flashing at 1Hz over the strobe entire operating range The strobe light shall consist of a xenon flash and associated lens reflector system Module module shall be a System Sensor Sync Circuit model listed to UL 464 and shall be approved for fire protective module shall synchronize SpectrAlert at 1Hz The module shall mount to a 4 11 16 x x 2 1 8 backbox The module shall also two Style Y class B circuits or one Style Z A circuit The module shall synchronize multiple Daisy chaining two or more synchronization together will synchronize all the zones they MAXIMUM STROBE CURRENT DRAW mA RMS 33 Volts 17.5 Volts module shall not operate on a coded power Information W indicates white coloring R red Mount Speaker only Speaker only high dB white Speaker strobe selectable candela 15 30 75 95 110 115 Speaker strobe selectable candela cd 135 150 177 185 Speaker strobe selectable candela dB Mount Speaker only Speaker only high dB Speaker strobe selectable candela 15 75 30 50 75 95 110 115 Speaker strobe selectable candela cd 135 150 177 185 Speaker strobe selectable candela dB 15 15 75 30 50 75 95 110 115 Speaker strobe selectable candela dB high cd 135 150 177 185 Retrofit plate red Retrofit plate white Ceiling mount backbox skirt red Ceiling mount backbox skirt white Wall mount backbox skirt red Wall mount backbox skirt white Wall mount trim ring red Wall mount trim ring white Ceiling mount trim ring red Ceiling mount trim ring white Add P to model number for plain housing no marking on the cover e g SPSW P document is not intended to be used for installation purposes We try to keep our product information and accurate We cannot cover all specific applications or anticipate all requirements All are subject to change without notice For more information contact Silent Knight Clintonville Road Northford CT 06472 1610 Phone 800 328 0103 Fax 203 484 7118 SpectrAlert and System Sensor are registered trademarks of Honeywell Inc

Related Files