Fike Cybercat Intelligent Low Profile Plug in Detectors P 1 52 01
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fike-cybercat-intelligent-low-profile-plug-in-detectors-p-1-52-01-2193647805.pdf |
---|---|
Type | |
Size | 732.50 KB |
Downloads |
Text Preview
CYBERCATTM INTELLIGENT LOW PROFILE DETECTORS Eclipse series intelligent low profile plug in detectors manufactured by Sensor is a peer to peer all digital protocol that allows for numerous such as fire security access and HVAC control Eclipse provides device response time with more flexibility than ever possible before This peer to peer protocol enables pinpoint accuracy in as little as one half without interference problems that can plague other systems Eclipse system distributes intelligence to the networked devices In fact turns every networked device into a peer capable of generating messages by the entire system Additionally with Eclipse no special cables are required making it ideal for retrofit applications isolator versions have on board short circuit isolators to prevent shorts on signaling line circuit SLC from disabling all devices on the intelligent loop 63 1052 63 1058 photoelectric detectors feature a unique optical sensing engineered to sense smoke produced by a wide range of combustion The sensing chamber employs features that minimize the effects of dust on its performance The detector is designed with tri color LED to detector status and can be programmed to make the LED blink or be green amber or red Dual electronic thermistors add 135 fixed thermal sensing on the 63 1053 63 1059 models 63 1039 63 1040 are spot type heat detectors designed to be for a setpoint range of 135 to 174 for ordinary detection or to 190 for intermediate detection Detectors in the ordinary range may be for either fixed or 15 rate of rise operation 55 051 Configuration IR Tool is designed to communicate with Eclipse via infrared signals The configuration tool will give the user the ability to with the panel and other devices through any selected device on the The 55 051 can read device information such as type loop address and along with set loop address branch and service date It can also initiate walk test and a device test The 55 051 features a 16 character liquid crystal and 17 button keypad in 63 1055 Base in 63 1054 Base in 63 1060 Base IR Tool 55 051 Removal Tool 20 1087 Also Sold Separately 20 1089 LED 02 3868 S 10th Street P O Box 610 Blue Springs Missouri 64013 0610 U S A 816 229 3405 816 229 0314 www fike com Spacing for Thermal Detectors Detectors set between 135o to 155oF or 175o to 50 foot spacing Detectors set between 156o to 174oF 15 foot spacing Relative Humidity 0 to 93 RH non condensing Thermal Ratings Fixed Temperature Setpoint 135oF 57oC Rate of Rise Detection 15oF min 8.3oC min High Temperature Heat 190oF 88oC Voltage Range 15 30 volts DC peak Standby Current max avg Thermal 215 24 VDC continuous broadcasts Photo Photo with Thermal 250 24 VDC broadcasts LED Current max 6.5 mA 24 VDC on Specifications Dimensions 1.3 H x 2.2 W x 7.7 L Communication Range Up to 30 feet Battery Life 168 hours typical usage Operating Temperature Range 32o to 122oF 0o to Relative Humidity 10 to 90 RH non condensing FEATURES SPECIFICATIONS Sleek low profile design Distributed intelligence Greater system design freedom Peer to peer communication Digital communication protocol Numerous applications Fire Security Access and HVAC Fast response time Superior noise immunity Low standby current Communicate with the devices via hand held tool Height 2.1 51 mm Diameter 6.1 155 mm installed in 63 1054 63 1060 4.1 104 mm installed 63 1055 63 1061 base Shipping Weight Heat 4.8 oz 136 g Photo Photo with Heat 5.2 oz 147 g Operating Temperature Range Photo 32o to 120oF 0o to 49oC Photo with Thermal 32o to 100oF 0o to 38oC Thermal to 100oF to 38oC 135o to setpoint High Temperature Thermal to 150oF 20o to 175o to 190oF setpoint MODELS Temperature ROR Hi Temp Thermal Detector Smoke Detector with Thermal Bases Flanged Mounting Base Flangeless Mounting Base Mounting Kit Flangeless Surface Mounting Kit Flanged Surface Mounting Kit Flange LED Annunciator Removal Tool 20 1089 included for 02 4985 5 ft Removal Head Detector Kit IR Tool Indicates models with built in isolators Model No Fike Corporation All Rights Reserved No P 1.52.01 May 2004 Specifications are subject to change without notice