Fike Cybercat Intelligent Modules P 1 53 01

File Preview
File Preview
Click below to download for free

File Data

Name fike-cybercat-intelligent-modules-p-1-53-01-6180392547.pdf
Type PDF
Size 694.19 KB
Downloads

Text Preview

55 041 IR Tool 55 051 INTELLIGENT MODULES Eclipse protocol manufactured by System Sensor is a peer to peer all digital from that allows for numerous applications such as fire security access HVAC control Eclipse series intelligent modules provides faster device time with more flexibility than ever possible before This digital peer protocol enables pinpoint accuracy in as little as one half second interference problems that can plague other systems Eclipse system distributes intelligence to the networked devices In fact turns every networked device into a peer capable of generating messages by the entire system Additionally with Eclipse no special cables are required making it ideal for retrofit applications isolator versions have on board short circuit isolators to prevent shorts on signaling line circuit SLC from disabling all devices on the intelligent loop monitor and control modules can be used to supervise and activate strobes door closers pull stations waterflow switches and more Each is rigorously designed and tested for electromagnetic compatibility and reliability in many cases exceeding industry standards Full size mount in a standard 4 x 4 x 2 1 8 junction box Wiring terminals are accessible for troubleshooting purposes Relay modules are to be designed for products connected to an alarm system and the mini monitor module can the wiring to the device for open circuits via an end of line resistor Monitor Modules are used to monitor the normally open of an auxiliary device In addition to monitoring the contact the device supervise the wiring to the device for open circuits via an end of line resistor device is capable of class A or class B operation small size of the 55 045 55 050 Mini Monitor Module allows it to fit devices or junction boxes behind devices Control Modules are used to switch an external power supply or amplifier to notification appliances The devices will supervise the wiring to auxiliary device for open and short circuits via an end of line resistor The module will also have the capability to monitor the external power input loss of power DC voltage supplies only This module is capable of Class A Class B operation Relay Modules are designed for use in activation of products are connected to an intelligent fire alarm system It provides two sets of C contacts that switch together one DPDT relay There is also an input is capable of monitoring a dry set of contacts for open or closed conditions Configuration IR Tool is a remote control designed to communicate Eclipse devices via infrared IR signals The remote control will give the the ability to communicate with the panel and other devices through any device on the loop The 55 051 can read device information such as type and address along with set loop address branch and service date It can also a walk test and a device test The 55 051 features a 16 character liquid display and a 17 button keypad S 10th Street P O Box 610 Blue Springs Missouri 64013 0610 U S A 816 229 3405 816 229 0314 www fike com FEATURES SPECIFICATIONS Peer to Peer Communication Distributed intelligence Greater system design freedom Digital communication protocol Numerous applications Fire Security Access and HVAC Fast response time Superior noise immunity Low standby current Mounts to standard 4 junction box Wiring terminals easily accessible Communicate with the devices via hand held tool Module Specifications Operating Voltage 15 30VDC Alarm Current 2.0 mA red LED on Temperature Range 32o to 120oF 0o to 49oC Relative Humidity 10 to 93 non condensing Dimensions 55 045 55 050 2.7 W x 1.3 H x 0.6 D Others 4.26 W x 4.2 H x 1.2 D 55 042 55 047 Standby Current Avg 560 mA max avg continuous External Power Supply 9 80VDC Normal Range 0 Trouble Range End of Line Resistance 39 k ohms included Maximum VAC Circuit Wiring Resistance 100 Ohms Standby Current 500 mA max avg continuous Dry Contact Short Circuit Current 30 mA max avg Relay Contact Ratings 3.0 A 30VDC resistive non coded 2 A 30VDC resistive coded 0.9 A 70.7VAC resistive non coded 0.7 A 70.7VAC inductive PF 35 non coded 55 051 Dimensions 1.3 H x 2.2 W x 7.7 L Communication Range Up to 30 feet Battery Life 168 hours typical usage Operating Temperature Range 32o to 122oF Relative Humidity 10 to 90 RH non condensing 55 041 55 046 Standby Current 485 mA max continuous broadcasts IDC Voltage 5.4VDC max VMaximum IDC Wiring Resistance 100 ohms 55 045 55 050 Standby Current 485 mA max continuous broadcasts 745 mA max continuous broadcasts IDC Shorted IDC Voltage 5.4VDC max Wire Length 6.5 Maximum IDC Wiring Resistance 100 ohms MODELS Versions Model No Module Module Control Module Monitor Module Module Module Control Module Monitor Module Module Barrier Mount Box IR Tool Versions Fike Corporation All Rights Reserved No P 1.53.01 May 2004 Specifications are subject to change without notice

Related Files