Fike D 1 06 01 Remote LED Annunciator (GP-10RA)

File Preview
File Preview
Click below to download for free

File Data

Name fike-d-1-06-01-remote-led-annunciator-gp-10ra-8029745163.pdf
Type PDF
Size 676.97 KB
Downloads

Text Preview

REMOTE LED ANNUNCIATOR GP 10RA Fike GatorPro GP 10RA is a compact cost effective LED Annunciator for use with the GP 10UD ten zone Fire Alarm The GP 10RA is capable of Alarm red and Trouble yellow LEDs for all ten Device Circuits IDCs The GP 10RA also provides status LEDs to display Power green Alarm red Trouble Supervisory yellow and Signals Silenced It also features remote control of critical system such as Reset Silence Acknowledge and Drill Switches for System Acknowledge Signal Silence and Reset with enable key status LEDs for Power green Alarm red Trouble Supervisory yellow and Signals Silenced yellow Listed S3271 pleasing semi flush mount design EIA 485 interface for reduced installation cost see reverse side for wiring diagram No programming necessary May be powered by 24 VDC from the host FACP or by remote power supplies requires filtered regulated power to 32 GP 10RA annunciators per GP 10UD terminal blocks for ease of installation and service be remotely located up to 6,000 feet 1828.8 m from host control panel piezo sounder with alarm and trouble resound to 2.188 5.556 cm deep minimum three gang electrical box FireoLite P N 10103 or or surface mounts to FireoLite SBB 3 surface backbox GP 10RA provides the GP 10UD Conventional Fire Alarm Control Communicator with an annunciator meeting applications It provides an array of LEDs to indicate system status including control switches for remote control critical system functions The GP 10RA annunciator provides the GP 10UD with up to 32 remote serially connected All field wiring terminations on the GP 10RA use removable compression type terminal blocks for ease of and circuit testing CommunicationS between the FACP and the annunciators are accomplished over an EIA 485 interface greatly reducing wire and installation cost over traditional systems Four wires total are required two for EIA 485 communications in twistedpair and two for 24 VDC regulated power Dip switches control local functions as piezo disable control switches keyswitch disable transmit receive mode Annunciators may be powered from host GP 10UD up to 7 or remote power supplies requires filtered regulated power LINE INFORMATION Fike P N 27 024 Remote LED type fire annunciator with ten Alarm red and Trouble yellow LEDs for initiating device circuit zone status Includes control switches for remote control of critical system functions key switch lock Fike P N 27 025 GP 10RA Interface Module one required per GP 10UD supports up to 32 GP 10RAs Fike P N 27 027 Three gang electrical box 2.188 5.556 cm min deep for semi flush mount application Fike P N 27 026 Three gang surface backbox for surface mount applications S 10th Street P O Box 610 Blue Springs Missouri 64013 0610 U S A 816 229 3405 816 229 4615 www fike com No D 1.06.01 TO BACKBOX ES GP 10RA annunciators can ONLY be in a three gang electrical box with a mini depth of 2.188 5.556 cm FireoLite P N 10103 or annunciators CANNOT be mounted in three electrical switch boxes connected together Note GP 10RA annunciators can be mounted to the surface backbox for surface mount applications 14.764 cm wide x 4.0 cm high x minimum 5.556 cm deep electrical box P N 10103 shown ACS MODE WIRING for Wiring Diagram above EIA 485 Maximum of 6,000 feet 1828.8 m total cable length from FACP to GP 10RA annunciators Circuit is Up to 32 GP 10RA annunciators may be used on the EIA 485 circuit The GP 10UD can power a maximum of GP 10RA annunciators If additional GP 10RA annunciators are connected the FireoLite FCPS 24F may be to supply additional power NOTE Power supplies used for this purpose must have their negative terminals together Between each GP 10RA annunciator are four wires a twisted shielded pair for data communications and a pair for VDC power Each GP 10RA may have ACK SIGNAL SILENCE DRILL and SYSTEM RESET switches Displays all ten initiating device circuits zones of GP 10UD No programming required for GP 10RA annunciators Fike Corporation All Rights Reserved No D 1.06.01 July 2005 Specifications are subject to change without notice

Related Files