Fike D 1 07 01 SHPPro ds
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fike-d-1-07-01-shppro-ds-6308259147.pdf |
---|---|
Type | |
Size | 714.15 KB |
Downloads |
Text Preview
SHP PRO Fike SHP PRO P N 10 063 is a Conventional Control system designed to a sophisticated reliable conventional detection system for use with clean extinguishing sprinkler pre action deluge watermist waterflow alarm and fire systems It is a microprocessor based system which can be easily configured a wide range of suppression applications SHP PRO is designed for use with Fike Clean Agent Fire Suppressant CO2 or pre action deluge suppression systems The main controller contains all required for a complete detection and control system suitable for most Optional modules which plug into the main circuit board are available add increased functionality to the system SHP PRO provides 10 Status LEDs AC Normal Alarm PreDischarge Supervisory Trouble Panel Silenced Abort Release Disabled Ground for instant feedback A diagnostic LED display is provided to help trouble any potential field problems provide current status and retain stored events Reset and Silence switch is provided to allow control of the system outputs and MEA 461 04 E S2203 3017159 1765 0900 135 SHP PRO can be configured for either one or two conventional detection circuits The detection circuits can be for sequential detection cross zone or single detector release on the configuration selected the SHP PRO also provides up to three initiating circuits to monitor contact Abort Manual Release Waterflow or Supervisory switches Four different abort types are available including a NYC option All five initiating circuits can be converted to Class A operation via the SHP PRO Class A Input P N 10 2450 All SHP PRO initiating circuits are inherently power limited A twelve position dip switch is used set all options notification appliance circuits rated for 2 amps 24 VDC are available Depending on the configuration each will provide distinct signaling for Alarm PreDischarge or Release conditions Separate Agent Release and Solenoid are provided to operate the suppression system A dedicated Disable switch is provided for release and audible All output circuits including solenoid and agent release circuits are power limited SHP PRO provides dedicated alarm trouble and supervisory SPDT contacts for annunciation and control If outputs are required up to two CRM4 Relay Modules can be added P N 10 2204 SHP PRO is available in multiple hardware configurations depending on the input power source 120 or 240 VAC color Gray or Red and mode of operation Clean Agent Clean Agent Sprinkler Sprinkler Watermist Releasing The system comes equipped with a 4.0 amp 24 VDC power source system has been designed to comply with the following standards NFPA 12 Carbon Dioxide NFPA 12A Halon 1301 Extinguishing Systems NFPA 13 Installation of Sprinkler Systems NFPA 15 Water Spray Fixed Systems NFPA 16 Deluge Foam water and Foam spray Systems NFPA 70 National Electric Code NFPA 72 Installation Maintenance and Use of Protective Signaling Systems NFPA 2001 Clean Agent Fire Extinguishing Systems S 10th Street P O Box 610 Blue Springs Missouri 64013 0610 U S A 816 229 3405 816 229 4615 www fike com No D 1.07.01 5 for multiple types of Suppression Clean Agent Carbon Dioxide Pre Action Sprinkler Deluge and Systems Class B Style B initiating circuits zone sequential manual release abort water flow and supervisory detection types Class B Style Y notification appliance circuits rated for 2.0 amps 24VDC Microprocessor based with hardware and software integration designed to guarantee reliability Dedicated release circuits compatible with agent release or solenoid actuation Optional Class A modules for notification appliances releasing circuits and initiating circuits LED display for status and troubleshooting pre discharge and discharge timers and continuous auxiliary output power 4.0 amp power supply surface or flush mount enclosure with removable door for releasing device service and sprinkler supervisory Gentex and System Sensor synch protocol enclosure 21 x 14.35 x 4 equipped with 50 wide lip for flush mounting PRO WIRING DIAGRAM B C Agent All Modes only R Red 120 VAC 240 VAC PCB Assy SHP PRO Agent All Modes PCB Assy SHP PRO Only Class A Input Module Class A Output Module CRM4 Relay Module Battery Assembly 2 7AH w wiring assembly Battery Assembly 2 18AH w wiring Fike Corporation All Rights Reserved No D 1.07.01 5 September 2005 Specifications are subject to change without notice