Fike Hochiki Smoke Detector Sensitivity Tester TSA-B110
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fike-hochiki-smoke-detector-sensitivity-tester-tsa-b110-4658710923.pdf |
---|---|
Type | |
Size | 615.09 KB |
Downloads |
Text Preview
TSA B110 SMOKE DETECTOR SENSITIVITY TESTER Hochiki America TSA B110 Smoke Detector Sen Tester is designed for efficient and accurate test of the sensitivity of smoke detectors For ease of in field applications the tester is easy to transport compact Two densitometer circuits allow the TSA Smoke Detector Sensitivity Tester to test both and photoelectric smoke detectors TSA B110 Smoke Detector Sensitivity Tester is a piece of electronic equipment The unit must used in a temperature range of 50 to 86 Sudden or dropping of the TSA B110 may damage the Operation will be affected if proper care is not Pull out the measuring unit drawer to expose the and AC plug connector Remove the AC cord Connect one end to the AC connector and the other end to a 120VAC outlet Turn the AC source switch on The circulating fan Allow five minutes for warm up to ensure stability the testing circuits Open the top cover and locate the wire leads and If you are using a detector base connect the wire to this base and mount the base to the installation plate provided Markings Source cable not used Signal line Common line the TSA B110 Use the photo ion change over switch to the type of detector ION or PHOTO which to be tested Use the voltage adjustment knob to adjust the to agree with the rated voltage of the detec being tested for SLK 12 use 17.0 VDC Use the densitometer adjustment knob to on back FEATURES Tests the sensitivity of Hochiki previous model photoelectric and ionization smoke detectors Lightweight and portable for easy use in the field Obscuration sensitivity testing similar to that of a 268 Smoke Box Voltage Adjustment Knob easily changes tester to the rated voltage of the detector Indicator lamp automatically lights at completion testing Voltage V AC 50 60 Hz Voltage 132V AC Generating Material Punk Stick Temperature Range to 86 Lbs subject to change without notice America Corporation Village Drive Suite 100 Buena Park CA 90621 2268 714 522 2246 cid 127 Fax 714 522 2268 Support 800 845 6692 or technicalsupport hochiki com x 11.02 x 7.87 the pointer to zero 0 continued a Detector Place a detector to be tested into the base in the sensitivity tester smoke chamber and close the lid Insert an ignited punk stick into the smoke producing chamber on the lower right side When the detector an indicator lamp lights the meter locks and a buzzer sounds Observe the value indicated by the meter a holding circuit locks the meter in place for about one minute Remove the punk stick and open the top cover Remove the detector Smoke will be exhausted and the densitometer meter will reset to The lamp and function will clear at this time Steps 7 through 14 to test additional detectors SOURCE SWITCH ADJUSTMENT KNOB DENSITOMETER KNOBS PHOTO ION SWITCH CHAMBER the TSA B110 will assure many years of reliable use It is recommended the maintenance be by qualified personnel every two years Consult with your Hochiki distributor for a technician in your area Hochiki America Corporation recommends returning the TSA B110 to the factory every two years for to ensure optimum performance America Corporation cid 127 TSA B110 subject to change without notice