Fike P 1 64 01 Conventional Manual Pull Station
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fike-p-1-64-01-conventional-manual-pull-station-0256891437.pdf |
---|---|
Type | |
Size | 691.81 KB |
Downloads |
Text Preview
CONVENTIONAL MANUAL PULL STATION Fike Conventional Pull Station is a cost effective feature packed series of manual fire alarm pull stations It was designed to meet multiple with the installer and end user in mind They feature a variety of including single and dual action versions provide conventional fire alarm control panels FACPs such as GatorPro PRO or intelligent control panels such as Cybercat and Cheetah Xi with an initiating input signal Its innovative design durable construction and mounting options make this simple to install maintain and operate contoured shape with light textured finish Aesthetically pleasing highly visible design color Meets ADA 5 lb maximum pull force Meets UL 38 Standard for Manually Actuated Signaling Boxes Easily operated single or dual action yet designed to prevent false alarms bumped shaken or jarred IN PULL DOWN handle latches in the down position to clearly the station has been operated The word appears on the top of the handle in bright yellow indicating operation of the station Operation handle features white arrows showing basic operation direction non English speaking persons Braille text included in finger hold area of operation handle and across top handle Multiple hex and key lock models available can be opened for inspection and maintenance without initiating an ID label viewable by simply opening the cover label is made of a long life material The words and are molded into the plastic to the alarm switch located inside terminal strip molded into backplate Terminal strip includes Phillips combination head captive 8 32 screws for connection to Initiating Device Circuit IDC Terminal screws backed out at factory and shipped ready to accept field up to 12 AWG 3.25 mm Terminal numbers are molded into the backplate eliminating the need for contacts are normally open Can be surface or semi flush mounted Semi flush mount to a standard gang double gang or 4 10.16 cm square electrical box Backplate is large enough to overlap a single gang backbox cutout by up to 12.7 mm version FUEGO available 20 1062 Models packaged in attractive clear plastic PVC clamshell style Point of packages Packaging includes a cutaway dust paint cover in shape pull station Pull Station UL S2203 FM 3020297 MEA pending CSFM pending S 10th Street P O Box 610 Blue Springs Missouri 64013 0610 U S A 816 229 3405 816 229 0314 www fike com No P 1.64.01 2 The words shall appear on the of the station in white letters approximately 3 4 MODELS 20 1061 and 20 1062 pull stations are non coded pull stations which provide a FACP with two open alarm initiating input signals is activated by pushing in then pulling down the handle A alarm input signal can be activated via a momentary rocker switch inside the unit This general alarm switch can be accessed by opening the cover with the supplied See diagram below LINE INFORMATION pull station with key lock pull station with key lock as 20 1061 with English Spanish labeling Cover backplate and operation handle are all molded of polycarbonate material Cover features white lettering and trim Red color matches System Sensor popular SpectrAlert series Fike manual pull stations provide a textured finger hold that includes Braille text In addition to PUSH IN and DOWN text there are arrows indicating how to the station provided for non English speaking in and then pulling down on the handle activates normally open alarm switch Once latched in the down the word appears at the top in yellow with a portion of the handle protruding at the as a visible flag Resetting the station is simple insert key twist one quarter turn then open the station front causing the spring loaded operation handle to return to original position The alarm switch can then be reset to its non alarm position manually by hand or by closing station front cover which automatically resets the Specifications Height 5.500 in 13.97 cm Width 4.121 in 10.467 cm Depth 1.390 in 3.531 cm Specifications contact ratings gold plated rating 0.25 A 30 or VDC ARCHITECTS Fire Alarm Stations shall be non code with a key reset lock in order that they may be tested and so that after actual Emergency Operation they cannot restored to normal except by use of a key An operated shall automatically condition itself so as to be visually as activated Manual stations shall be constructed of colored LEXAN or polycarbonate equivalent with visible operating instructions provided on the cover word FIRE shall appear on the front of the stations in letters 1.00 inches 25.4 mm or larger Stations shall suitable for surface mounting on matching backbox or mounting on a standard single gang double gang 4 10.16 cm square electrical box and shall be installed the limits defined by the Americans with Disabilities ADA or per national local requirements Manual shall be Underwriters Laboratories listed Fike Corporation All Rights Reserved No P 1.64.01 2 August 2005 Specifications are subject to change without notice