Fike P 1 76 01 100 Series Low Profile Plug In Smoke Detector
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fike-p-1-76-01-100-series-low-profile-plug-in-smoke-detector-6398720541.pdf |
---|---|
Type | |
Size | 690.05 KB |
Downloads |
Text Preview
100 SERIES LOW PROFILE PLUG IN SMOKE DETECTOR Sensor 100 Series Plug in Smoke Detectors offer superb and reliability in a profile which is just 1.6 4.2 deep Fike P N 67 1040 ionization sensor can be used a variety of different adapter bases in several wiring and voltages Other features include low current stable performance in high air velocities built in tamper base design remote LED option removable cover built in test switch 100 Series is designed to meet the performance criteria by UL Their sensing chambers are sealed against pressure air flow dirt and insects This chamber is by a fine mesh screen which can be cleaned or Additional key features include interchangeable ion photo heads a variety of mounting bases and a full line of 100 Series ionization smoke detectors include a single dual chamber design that senses smoke particles This exhibits excellent stability significantly reducing alarms and provides good performance at higher air 100 Series photoelectronic smoke detectors contain a optical sensing chamber designed to sense smoke produced by a wide range of combustion sources A integrated circuit incorporates signal processing to false alarms Voltage Alarm Current Current low profile design housing design for both ion and photo models with 400 Series product LEDs blink in standby providing 360 visibility sensitivity metering of detector to meet the requirements of NFPA 72 range of adapter bases available with built in shorting spring Listed S911 MEA Approved 205 94 E 7272 1209 159 63 1014 67 1040 CS308 MSFM Approved 1973 Weight Listed Velocity Range Range Detector Spacing Adapter Base Selection Guide 40mA Standby 85mA Standby Ion Photo oz 102 g h 42 mm mm dia unflanged base mm dia flanged base retardant thermoplastic to 120 0 to 49 0 500 fpm 0 2.5 m s 0 3000 fpm 0 15.2 m s RH noncondensing smooth ceilings as defined in NFPA 72 spacing of 30 feet 900 sq may be used as a guide Other spacing may be used depending on height high air movements and other conditions or response No P 1.76.01 S 10th Street P O Box 610 Blue Springs Missouri 64013 0610 U S A 816 229 3405 816 229 4615 www fike com SPECIFICATIONS ionization detector model shall be equipped with a dual chamber unipolar sensing chamber The nominal sensitivity the detector shall be 1.0 ft as measured in a UL smoke box and shall not alarm when it is exposed to wind gusts to 500 feet per minute The photoelectronic detector model shall have a nominal sensitivity of 3.0 ft as measured a UL smoke box with a nominal signal to noise ratio of 2.0 Both ionization and photoelectronic detector models shall available The detector shall be quipped with a light emitting diode LED that is visible from the floor This LED blink every ten seconds to indicate that the detector is operational in standby and latch on as a visual indication of The detector shall be capable of applying an output voltage to an optional remote LED annunciator as an of its status The photoelectronic detector shall include built in circuitry that performs a functional test of all circuits at least once every 40 seconds without the need for generating smoke It shall be possible to perform a sensitivity and performance test on the detector without the need for generating smoke The test method shall all detector circuits The detector screen and cover assembly shall be easily removable for cleaning or replacement It maintain stable operation when it is exposed to wind gusts of up to 3000 feet per minute The detector shall use a low profile design that is both unobtrusive and aesthetically pleasing A line of plus in bases for a variety of shall be available for use with the detectors Wire connections shall be made by means of a clamping plate screw These bases shall allow for mounting directly to a surface or to a 3 1 2 or 4 octagon box BASE SELECTION GUIDE P N Model No Loop Type Current Limit Type A C A C A C Draw on mA AC Max contingent on panel compatibility be limited by control panel base Contact Ratings or Inductive 60 power factor load A 2.0A at 30 VAC DC C 0.6A 110VDC 2.0A at 30VDC at 125VAC 2.0A at 30VAC BOX SELECTION GUIDE P N Model No Single Gang B112LP B116LP 4 Square 50 mm 60 mm 75 mm Box depth contingent on base and wire size Refer to National Electrical Code or local applicable codes for recommendations INFORMATION ionization detector Must be mounted to one of the B100 Series or B400 bases listed in Adapter Base Selection Guide photoelectronic detector Must be mounted to one of the B100 Series B400 Series bases listed in Adapter Base Selection Guide replacement flange for B400 Series flanged bases annunciator for 2 or 4 wire systems 3 32V Use with ion and photo detectors Fits standard single gang electrical box base Requires an external 24 VDC power supply Mounts to 4 square box 1 1 2 minimum depth 2 1 8 recommended sensitivity test tool See below Use with most analog or digital mulimeters NFPA 72 requirement for sensitivity testing mounting kit provides for entry of surface wiring conduit use with P N 60 1031 mounting base only of line relay for power supervision 12 24 VDC systems magnet magnet with 32 telescoping handle removal tool Allows installation and or removal of 100 Series detector from base in high ceiling installation when used with 02 4986 pole for 02 4985 Comes in three 5 ft sections dust cover for 100 Series smoke detectors mounting kit for P N 63 1014 detector P N 60 1031 sold separately P N P N P N P N Fike Corporation All Rights Reserved No P 1.76.01 September 2005 Specifications are subject to change without notice