Fike P 1 80 01 Watertight 4 Wire Low Flow Duct Smoke Detector

File Preview
File Preview
Click below to download for free

Text Preview

WATERTIGHT 4 WIRE LOW FLOW DUCT SMOKE DETECTOR System Sensor Fike P N 63 1051 Watertight Innovair a NEMA 4 duct smoke detector rated for installation and in non hazardous indoor and outdoor applications The is UL listed as an environmentally watertight enclosure a degree of protection against falling dirt rain dust splashing and hose directed water this 4 wire photoelectronic Innovair features Low Flow technology capable of sensing smoke in velocities from 100 to 4,000 feet per minute 0.5 to 20.3 63 1051 Watertight Innovair can be directly mounted onto HVAC equipment or used in other environmentally applications which fall within its specified temperature Since the Watertight Innovair is NEMA 4 rated no enclosure is needed The Watertight Innovair the same form fit and wiring terminations as the Innovair but meets the NEMA 4 requirements an unsurpassed level of environmental protection Listed addition to being the only watertight duct smoke detector on the market this revolutionary Innovair solves many low airflow duct applications where reliable smoke detection is critical Innovair with Low Flow technology detect smoke in air speed velocities of as low as 100 feet per minute while continuing the same reliable up to 4,000 feet per minute Innovair family is designed for simplified installation and easy maintenance The modular construction allows for cleaning and simple field replacement of the UL recognized power and sensor boards Sensor has again set the standard for HVAC smoke detection technology The Watertight Innovair 63 1051 unsurpassed protection in environmentally harsh and low air flow environments Duct smoke detectors have specific limitations Smoke Detectors are NOT a substitute for an open area smoke detector NOT a substitute for early warning detection and NOT a replacement for a building regular fire detection system to NFPA 72 and 90A for additional information about the proper application of duct smoke detectors To maintain the watertight properties of this duct smoke detector watertight conduit and fittings must be used the product with the conduit holes facing downwards if possible NEMA Type 4 UL listed for non hazardous indoor and outdoor applications High Low voltage barrier velocity rating from 100 to 4000 feet per minute 0.5 to 20.32 m sec interconnectability for multi fan shutdown up to 10 air handlers telescopic sampling tube cover tamper trouble signal VAC DC or 120 241 VAC operation with two DPDT Form C relay contacts S 10th Street P O Box 610 Blue Springs Missouri 64013 0610 U S A 816 229 3405 816 229 4615 www fike com No P 1.80.01 reset button Outside mounting tabs and quick mounting to round or rectangular ducts from 1 0.3 3.7 meters wide to clean recognized field replaceable power and sensor boards test station option sounder option 268A listed warranty SPECIFICATIONS air duct smoke detector shall be a System Sensor Fike P N 63 1051 series watertight duct smoke detector The shall meet the NEMA 4 standard for enclosures for electrical equipment It shall be UL listed for non locations for installation and use in both indoor and outdoor applications The detector shall be constructed as to provide a degree of protection against falling dirt rain windblown dust splashing water hose directed water incidental contact The detector housing shall be UL listed per UL 268A specifically for use in air handling The detector shall operate at air velocities of 100 feet per minute to 4000 feet per minute 0.5 to 20.3 m sec unit shall be capable of controlling up to ten 10 air handling systems when interconnected with other detectors detector shall be capable of providing a trouble signal in the event that the front cover is removed It shall be of local testing via magnetic switch or remote testing using 02 3869 Multi Signaling Accessory or 02 4998 Test Station The unit shall be reset by local reset button or remote test station The duct smoke detector shall incorporate an airtight smoke chamber in compliance with UL 268A Standard for Smoke Detectors for Applications The housing shall be capable of mounting to either rectangular or round ducts without adapter An integral filter system shall be included to reduce dust and residue effects on detector and housing thereby maintenance and servicing Sampling tubes shall either be telescoping or be easily installed by passing through duct housing after the housing is mounted to the ducts The unit shall provide a spatial separation of no less than 6.4mm and or a physical barrier between the high and low voltage terminals The enclosure shall meet all NEC and NFPA standards regarding electrical junction boxes Terminal connections shall be the strip and method suitable for 12 18 AWG wiring GUIDE wiring diagram for 4 wire duct smoke detectors Weight Enclosure Rating Temperature Range Temperature Range Humidity Range Air Velocity Range 37 cm Length 5 1 2 14 cm Width 2 3 4 4 cm Depth lbs 1.7 kg 4 Watertight indoor Outdoor to 131 0 ti 55 to 158 30 to 70 to 93 relative humidity non condensing to 4000 ft min 0.5 to 20.3 m sec RATINGS DH100ACDCLWP INCLUDES DETECTOR VAC 50 60 Hz VAC 50 60 Hz VAC 50 60 Hz Supply Voltage Capacitance Voltage Time with RTS451 Time by power down Up Time Response Time Test Standby Current Alarm Current Initiation Contacts SPST Auxiliary contacts DPDT VDC max VDC min to 0.3 sec sec max sec max to 17 sec max VAC min to 0.3 sec sec max sec max to 17 sec VAC min to 0.3 sec sec max sec max to 17 sec Requirements Using No Accessories mA mA mA RMS mA RMS mA RMS mA RMS Ratings 30 VAC DC 0.6 power factor 30 VDC 250 VAC VAC min to 0.3 sec sec max sec max to 17 sec mA RMS mA RMS detector label detector label detector label detector label Contacts SPDT 30 VDC resistive 2.0A 125 VAC resistive Alarm auxiliary contacts must switch 100 mA minimum at 5VDC Alarm auxiliary contacts shall not be to initiating circuits of control panels Use the alarm initiation contact for this purpose P N Current Loads at 24 VDC Max Max max Max Max Max Max Max When a unit is powered at the 120VAC or 220 240VAC input any of accessories may be used such that the given accessory loads are mA or less in the standby state 110 mA or less in the alarm state Interconnect Notes using the interconnect feature all interconnected units be powered with the same independent supply must be maintained throughout the interconnect wiring terminal 12 on unit 1 to terminal 12 on unit 2 and so Similarly connect terminal 1 on unit 1 to terminal 1 on unit and so on diagram for 63 033 to 02 11490 diagram for 02 3869 02 4998 interconnect feature diagram for 63 033 to 02 11489 interconnect feature INFORMATION P N photoelectric duct detector with low flow technology P N photoelectric detector board 4 wire power board sampling tube duct widths 1 0.3 0.6 m sampling tube duct widths 2 0.6 1.2 m sampling tube duct widths 4 1.2 2.4 m sampling tube duct widths 8 2.4 3.7 m telescoping

Related Files