Fike P 1 81 01 2 wire low flow duct smoke detector
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fike-p-1-81-01-2-wire-low-flow-duct-smoke-detector-3849617052.pdf |
---|---|
Type | |
Size | 856.48 KB |
Downloads |
Text Preview
2 WIRE LOW FLOW DUCT SMOKE DETECTOR System Sensor Innovair Fike P N 63 1050 is a 2 wire air duct smoke detector capable of sensing s in air velocities from 100 to 4000 feet per minute 0.5 20.32 m sec This Innovair features Low Flow technology duct smoke detection throughout a broad range of environments Many difficult to solve HVAC occur in low airflow duct applications where smoke detection is critical Innovair with Low Flow can detect smoke at air speed velocities of 100 per minute or greater while continuing the same reliable to 4000 feet per minute Innovair family is designed for simplified installation and maintenance The modular construction allows for easy and uncomplicated field replacement of the UL power and sensor boards Duct smoke detectors have specific limitations Listed Smoke Detectors Are NOT a substitute for an open area smoke detector NOT a substitute for early warning detection and NOT a replacement for a building regular fire detection system to NFPA 72 and 90A for additional duct smoke detector application information Outside mounting tabs velocity rating from 100 to 4000 feet per minute 0.5 to 20.32 m sec telescopic sampling tube 12 24 VDC operation reset button and quick mounting to round or rectangular ducts from 1 0.3 3.7 meters wide models available to clean recognized field replaceable power and sensor boards test station option annunciator option cover for convenient visual inspection 268A listed warranty SPECIFICATIONS air duct smoke detector shall be a System Sensor Model Fike P N 63 1050 Series Duct Smoke Detector The housing shall be UL listed per UL 268A specifically for use in air handling systems The detector shall operate air velocities of 100 feet per minute to 4000 feet per minute 0.5 to 20.32 m sec It shall be capable of local testing magnetic switch or remote testing using P N 02 4998 Remote Test Station The unit shall be rest by local reset or P N 02 4998 The duct detector housing shall incorporate an airtight smoke chamber in compliance with 268A Standard for Smoke Detectors for Duct Applications The housing shall be capable of mounting to either or round ducts without adapter brackets An integral filter system shall be included to reduce dust and effects on detector and housing thereby reducing maintenance and servicing Sampling tubes shall either be or easily installed after the housing is mounted to the duct by passing through the duct housing The enclosure meet all applicable NEC and NFPA standards regarding electrical junction boxes Terminal connections shall be the strip and clamp method suitable for 12 18 AWG wiring No P 1.81.01 S 10th Street P O Box 610 Blue Springs Missouri 64013 0610 U S A 816 229 3405 816 229 4615 www fike com SPECIFICATIONS Weight Temperature Range Humidity Range Duct Velocity RATINGS Voltage Voltage Capacitance Ratings Ratings Voltage Time Time 37 cm Length 5 1 2 14 cm Width 2 3 4 7 cm Depth lbs 1.5 kg to 131 0 to 55 to 93 relative humidity to 4000 ft min 0.5 to 20.32 m sec VDC Volts peak to peak maximum VDC minimum 35 VDC maximum 120 maximum VDC minimum at 10mA VDC maximum at 100mA current must be limited to 100mA or less by the control panel If the P N 02 3868 remote lamp operates within the specified alarm VDC minimum Sec maximum Sec maximum Sensor provides system flexibility with a variety of accessories including two remote test stations and several means of visible and audible system annunciation As with our duct detectors all duct smoke detector are UL listed 02 11490 Annunciator S4011 02 4998 Test Station Key UL S2522 02 3869 Test Station S2522 02 3868 Annunciator S2522 20 130 134 Sounder S3593 WIRING GUIDE wiring for 2 wire duct smoke detectors detectors powered from initiating device circuit diagram for 02 4998 Remote Test Station to 2 wire duct smoke detectors 02 4998 INFORMATION P N P N photoelectric duct smoke detector photoelectric detector board 4 wire power board sampling tube duct widths 1 0.3 0.6 m sampling tube duct widths 2 0.6 1.2 m sampling tube duct widths 4 1.2 2.4 m sampling tube duct widths 8 2.4 3.7 m telescoping sampling tube end cap for Fike P N 02 4675 accessory rest station with key lock test station annunciator with piezo alarm test module annunciator alarm LED air filters two per package magnet cap for metal sampling tubes replacement screen sounder add on strobe lens Fike Corporation All Rights Reserved No P 1.81.01 September 2005 Specifications are subject to change without notice